FIGURE 1: DIMENSIONS
INTERFACE SERIES
Installation & Operation Instructions
PTP
Phone: 1-888-967-5224
Website: workaci.com
GENERAL INFORMATION
Two models of the PTP accept either a 3 to 15 or 3
to 30 psig pneumatic pressure input and convert
it to one of four proportional analog output
ranges of 1-5, 2-10, 3-15 VDC or 4-20 mA which are
jumper shunt selectable. A plugged gauge port is
provided in the aluminum manifold for local
mechanical indication via an optional 0 to 30 psi
gauge. Custom calibration is available upon
request for an additional charge. This will speed
up installation time for the end user.
MOUNTING INSTRUCTIONS
Circuit board may be mounted in any position. If
circuit board slides out of snap track, a
non-conductive “stop”may be required. Use only
ngers to remove board from snap track. Slide
out of snap track or push against side of snap
track and lift that side of the circuit board to
remove. Do not flex board or use tools.
WIRING INSTRUCTIONS
PRECAUTIONS
• Remove power before wiring. Never
connect or disconnect wiring with power
applied.
• When using a shielded cable, ground the
shield only at the controller end. Grounding
both ends can cause a ground loop.
• It is recommended you use an isolated
UL-listed class 2 transformer when powering
the unit with 24 VAC. Failure to wire the
devices with the correct polarity when
sharing transformers may result in damage
to any device powered by the shared
transformer.
• If the 24 VDC or 24VAC power is shared
with devices that have coils such as relays,
solenoids, or other inductors, each coil must
have an MOV, DC/AC Transorb, Transient
Voltage Suppressor (ACI Part: 142583), or
diode placed across the coil or inductor. The
cathode, or banded side of the DC Transorb
or diode, connects to the positive side of the
power supply. Without these snubbers, coils
produce very large voltage spikes when
de-energizing that can cause malfunction or
destruction of electronic circuits.
• All wiring must comply with all local and
National Electric Codes.
3.25” (82.55mm)
2.18”
(55.49mm)
0.70”
(17.78mm)
2.18”
(55.37mm)
3.88” (98.55mm)
PTP
PTP With Gauge
2.30” (58.42mm)
3.63”
(92.13mm)
2.95” (74.93mm)
Ø1.64”
(41.66mm)
FIGURE 2: WIRING
FIGURE 3: J5 SHUNT SWITCH
Automation Components, Inc.
2305 Pleasant View Road | Middleton, WI 53562
Phone: 1-888-967-5224 | Website: workaci.com
Page 2
Version: 4.0
I0000484
Output Selector
WIRING INSTRUCTIONS (Continued)
The gauge port will accept a miniature 1/8" FNPT back-ported pressure gauge to allow direct reading of
branch line pressure. The gauge should be sealed with Teon sealing tape. A backup wrench should be
used to hold the manifold. ADJUSTMENT OF INSTALLED GAUGES. If installation requires adjustment of the
gauge for proper reading of the face, turn the gauge no more than 1/2 turn in either direction. O rings in
the bottom of the gauge port will allow this without leakage.
The surface between the manifold and pressure transducer is a pressure seal. Do NOT stress the circuit
board or allow the manifold to move. Hold the manifold in one hand while installing pneumatic tubing
onto the tting and use care when removing tubing to avoid damaging tting or moving manifold.
SETUP
With power o, select jumper position on jumper block J5 corresponding to the output required (see
Figure 3).
CHECKOUT
Apply power to terminals "PWR" (+) and ( - ). The PTP will begin
tracking and responding to the pressure input signal instantly.
Apply minimum and maximum pressure (or vacuum) and
measure response. Check test meter for proper scale selection
and correct lead connection. Response between the minimum
and maximum values will be linear, therefore software
algorithms should be easy to derive.
J5
J5 J5
J5
15V
5V 10V
20mA
Pressure Input
3 to 15 psi
3 to 30 psi
(Specify Range when ordering)
24 VAC/VDC (+)
Analog Output (+)
Common (-)
Power
LED
OFFSET
GAIN
PRODUCT SPECIFICATIONS
Automation Components, Inc.
2305 Pleasant View Road | Middleton, WI 53562
Phone: 1-888-967-5224 | Website: workaci.com
Page 3
Version: 4.0
I0000484
WARRANTY
The PTP Series is covered by ACI’s Two (2) Year Limited Warranty, which is located in the front of ACI’S SENSORS &
TRANSMITTERS CATALOG or can be found on ACI’s website: www.workaci.com.
W.E.E.E. DIRECTIVE
At the end of their useful life the packaging and product should be disposed of via a suitable recycling
centre. Do not dispose of with household waste. Do not burn.
24 VDC or 24 VAC, -6%/+10%
50 mA maximum @ 24 VDC
1-5 VDC @ 250 | 2-10 VDC @ 500 | 3-15 VDC @ 750 | 4-20 mA @ 500
PTP 3-15: 3 to 15 psig | PTP 3-30: 3 to 30 psig
2% full scale at room temperature | 3% full scale across operating
temperature range
Furnished with integral-in-barb 80-100 micron lter (Part # PN004).
90° Pluggable Screw Terminal Blocks
16 (1.31 mm) to 26 AWG (0.129 mm)
0.5 Nm (Minimum); 0.6 Nm (Maximum)
1/4" O.D. nominal (1/8” I.D.) polyethylene
Removeable brass barbed tting in machined aluminum manifold
Plugged 1/8-27-FNPT gauge port | Gauge installed at additional cost
0-30 psig (0-200 kPa)
± 2.5% Midscale (± 3.5% Full Scale)
35 to 120°F (1.7 to 48.9°C)
10 to 95% non-condensing
-20 to 150°F (-28.9 to 65.5°C)
NON-SPECIFIC INFORMATION
Supply Voltage:
Supply Current:
Output Signal Range (@
Impedance):
Input Pressure Range:
Output Analog Accuracy:
Filtering:
Connections:
Wire Size:
Terminal Block Torque Rating:
Connections | Pneumatic
Tubing Size-Type:
Pneumatic Fitting:
Gauge Pressure Range (Gauge
Models):
Gauge Pressure Accuracy
(Gauge Models):
Operating Temperature Range:
Operating Humidity Range:
Storage Temperature:
Page 4
Automation Components, Inc.
2305 Pleasant View Road
Middleton, WI 53562
Phone: 1-888-967-5224
Website: workaci.com
Automation Components, Inc.
2305 Pleasant View Road | Middleton, WI 53562
Phone: 1-888-967-5224 | Website: workaci.com
Version: 4.0
I0000484

Other aci I/O System manuals

aci RM2432D Series Installation instructions

aci

aci RM2432D Series Installation instructions

aci ANALOG INTERFACE Series Installation instructions

aci

aci ANALOG INTERFACE Series Installation instructions

aci AIM2 Installation instructions

aci

aci AIM2 Installation instructions

aci RD2432D Series Installation instructions

aci

aci RD2432D Series Installation instructions

Popular I/O System manuals by other brands

turck excom EG-VA655526/113-0200/134 quick start guide

turck

turck excom EG-VA655526/113-0200/134 quick start guide

FireClass Precept EN Panel Installation & commissioning manual

FireClass

FireClass Precept EN Panel Installation & commissioning manual

WAGO 750-402 manual

WAGO

WAGO 750-402 manual

Seneca Z-DAQ-PID user manual

Seneca

Seneca Z-DAQ-PID user manual

ICPDAS WinCon-8000 Getting started

ICPDAS

ICPDAS WinCon-8000 Getting started

National Instruments 653 Series user manual

National Instruments

National Instruments 653 Series user manual

Industrial Shields M-DUINO PLC ARDUINO ETHERNET 58 manual

Industrial Shields

Industrial Shields M-DUINO PLC ARDUINO ETHERNET 58 manual

Festo CTEU-PN Original instructions

Festo

Festo CTEU-PN Original instructions

YASKAWA AI-14B user manual

YASKAWA

YASKAWA AI-14B user manual

Helmholz TB20 manual

Helmholz

Helmholz TB20 manual

Aviom 6416m user guide

Aviom

Aviom 6416m user guide

MG R7E-MS4 instruction manual

MG

MG R7E-MS4 instruction manual

M-system R7G4FML3-6-DA16 instruction manual

M-system

M-system R7G4FML3-6-DA16 instruction manual

National Instruments PXIe-4322 CALIBRATION PROCEDURE

National Instruments

National Instruments PXIe-4322 CALIBRATION PROCEDURE

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

rtd DM35956HR user manual

rtd

rtd DM35956HR user manual

LEGRAND Wattstopper WIO-4 installation instructions

LEGRAND

LEGRAND Wattstopper WIO-4 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.