Billi XI Slimline Font User manual

Installation guide
XI Slimline Font – Proud & Flush Mount

2
Installation requirements.
Proud & Flush Mount
Components included
Before commencing installation, ensure
you have identified the following pieces:
1. Font tray
2. Font cover plate set 1 set (3 piece)
3. Sealing Gaskets x 3
4 Drain adapter
5. O-ring
6. M5 x 40mm screw
7. Elbow 3/4”
8. Bush
9. Hose adaptor
10. M6 x 45mm hex bolt x 4
11. M6 Flange nuts x 4
12. Font washer
13. Font mounting bracket x 4
Determine unit location
Plan the installation. Dispenser tube lengths,
benchtop and cupboard restraints and drainage
requirements must be considered when
determining location. Use template enclosed
for drilling and cut-out details. Refer also to
appliance installation requirements supplied
with Drinking Water System.
Drainage location
Careful design and installation is essential
to provide satisfactory drainage performance
and to prevent later blockages. The Billi Font
is designed to be able to be connected to
a dishwasher nipple using either flexile or
rigid tubing or copper tubing. Where a
horizontal run is needed, we recommend
20mm or 25mm copper tubing be used.
An adapter bush is supplied for use where
a standard 40mm trap and drain is installed.
IMPORTANT
If drain is to be connected to a dishwasher
nipple, ensure hole through nipple is drilled
to at least ø12.7mm (1/2”) and de-burred,
to allow adequate flow.
Drain must be installed with a continual
fall along the entire length of the tube.
The Billi Fixture is to be installed by
a licensed tradesperson in accordance
with as 3500.4 Or AS/NZ 3500.4.2
And in compliance with applicable
state regulatory requirements.
Diagram 1
Font tray
O-ring
Drain adapter
M5 x 45 screw

3
1. Marking and Drilling Holes
a. Cut out hole in benchtop using
measurement shown in Diagram 7a on
the following page.
2. Fitting Drain Adapter
a. Fit O-ring to Drain adapter.
b. Fit Drain adapter to tray. Tighten M5
screw, Note: Do NOT over-tighten
the screw.
c. Drain tube and elbow fitting are to
face dispenser mount hole – refer to
diagram 1 on previous page.
3. Fitting Billi Font to Benchtop
a. Install the sealing gasket around the edge
of the font tray. Refer to Diagram 2.
b. Lower the Font tray into the cut out and
insert 4 x M6 bolts, one in each corner.
c. Fit the clips and M6 Flange nuts to all 4
bolts – refer to Diagram 3.
e. Tighten nuts until rim sits flat on
benchtop. Do NOT over-tighten nuts.
4. Fit front and rear cover plates
a. Remove protective film from cover
plate set.
b. Remove bottom gasket covers and insert
into gasket grooves.
c. Remove gasket cover and insert cover
into font tray.
d. Ensure holes in rear cover plate align with
the holes in the font tray.
e. Apply pressure around edge of plate(s)
to ensure proper gasket seal.
5. Install the tap – refer to diagram 4.
a. Feed the dispenser tube and tap base into
hole in the rear of the font.
b. Feed lock mechanism components onto
the end of the dispenser tube in the
following order:
i. Washer
ii. Locking bush
iii.Locking nut.
c. Slide components into position and
tighten the locking nut.
Note: Do NOT over tighten.
6. Connect Tubing to Underbench Module
a. Connect dispenser tubing to underbench
module as per installation instructions
supplied with your unit.
7. Connect Drainage
a. Connect drainage tubing with reference
to Drainage Requirement instructions
on previous page. Drainage tube must
be installed with a continual fall along
the entire length of the tube and must be
adequately clipped and supported.
Installation procedure.
Proud Mount
Bench Font tray
Clip Diagram 3
M6
Bolt
Seal between
Font and Benchtop
Diagram 2
Bench Font tray
Gasket
Bench
Plate
Font tray
Washer
Locking Bush
Locking Nut
Diagram 4
291mm
191mm
Diagram 5

4
Hole Cut-Out Dimensions
– See Template for actual size,
Before using check dimensions
are accurate.
Installation procedure.
Proud Mount
272mm
SIDE
172mm
FRONT
Not to scale
191.0mm
272.0mm
>
25mm
Bench
Font
Diagram 7bDiagram 7a
Bench
TOP VIEW
EXPLODED DIAGRAM

5
1. Marking and Drilling Holes
a. Cut out hole in bench top according to
Diagram 7a on page 6. Use appropriate
router bits to give R5.0 edges.
2. Apply thick coat of moisture primer to all
cut surfaces
3. Fitting Drain Adapter
a. Fit O-ring to Drain adapter.
b. Fit Drain adapter to tray. Insert and tighten
M5 screw, Note: Do NOT over-tighten
the screw.
c. Drain tube and elbow fitting are to
face dispenser mount hole –refer to
diagram 1 on page 2.
4. Fitting Billi Font to Benchtop
a. Install the sealing gasket around the edge
of the font tray. Refer to Diagram 2.
b. Lower the Font tray into the cut out and
insert 4 x M6 bolts, one in each corner.
c. Fit the clips and M6 Flange nuts to all 4
bolts – refer to Diagram 3.
e. Tighten nuts until rim sits flat on
benchtop. Do NOT over-tighten nuts.
5. Fit front and rear cover plates
a. Remove protective film from cover
plate set.
b. Remove bottom gasket covers and insert
into gasket grooves.
c. Remove gasket cover and insert cover
into font tray.
d. Ensure holes in rear cover plate align with
the holes in the font tray.
e. Apply pressure around edge of plate(s)
to ensure proper gasket seal.
6. Install the tap – refer to diagram 4.
a. Feed the dispenser tube and tap base into
hole in the rear of the font.
b. Feed lock mechanism components onto
the end of the dispenser tube in the
following order:
i. Washer
ii. Locking bush
iii.Locking nut.
c. Slide components into position and
tighten the locking nut.
Note: Do NOT over tighten.
7. Connect Tubing to Underbench Module
a. Connect dispenser tubing to underbench
module as per installation instructions
supplied with your unit.
8. Connect Drainage
a. Connect drainage tubing with reference
to Drainage Requirement instructions
on previous page. Drainage tube must
be installed with a continual fall along
the entire length of the tube and must be
adequately clipped and supported.
Installation procedure.
Flush Mount
Seal between
Font and Benchtop
Diagram 2
Bench Font tray
Gasket
Bench
Plate
Font tray
Washer
Locking Bush
Locking Nut
Diagram 4
Diagram 3
Bench Font tray
Clip
M6
Bolt
291mm
191mm
Diagram 5

6
>25mm
Bench
Font
Installation procedure.
Flush Mount Hole Cut-Out Dimensions
– See Template for actual size,
Before using check dimensions
are accurate.
191.0mm
TOP VIEW
174.0mm
291.0mm
274.0mm
FRONT
SIDE
Diagram 7a
Bench
Font cut out:
174mm (wide) x 274mm (long)
Rebate cut: 5.5mm (deep)
191mm (wide) x 291mm (long)
Corner Radius: 5mm
Tolerance: +/- 0.2mm
8.5mm
8.5mm
8.5mm
8.5mm
Not to scale
Diagram 7b
EXPLODED DIAGRAM


Billi Australia Pty Ltd
42 Lucknow Crescent, Thomastown
Victoria 3074 Australia
Telephone +61 3 9469 0400
Facsimile +61 3 9469 0499
www.billi.com.au
Designed and manufactured in Australia.
As Billi Australia Pty Ltd has a policy of
continual improvement, all details are
subject to change without notice. All
goods are sold subject to our published
terms and conditions. Billi is a registered
trademark. 0618
If any problems or difficulties arise contact Billi Australia Pty Ltd: Phone 1800 812 321 (Free call).
To validate your warranty refer to the warranty card or validate online at www.billi.com.au
For information on our filtration and service contracts please contact Billi Customer Service on
Table of contents
Other Billi Kitchen & Bath Fixture manuals