C-Data HF300-3815C-22D User manual

User’s manual
1550nm Erbium-Doped Fiber Amplifier
HF300-3815C-22D
User’s Manual

User’s manual

User’s manual
Content
1. Safety instructions......................................................................................................1
2. Production structure description................................................................................2
2.1 Equipment dimension .......................................................................................2
2.2 The front panel diagram....................................................................................2
2.3 The rear panel diagram .....................................................................................2
3. Operation instructions................................................................................................3
3.1 Connection........................................................................................................3
3.2 Turn on/off procedure.......................................................................................3
3.3 LED indicator description.................................................................................3
3.4 Button description.............................................................................................4
3.5 Display menu description .................................................................................4
4. Alarm breakdown analysis.......................................................................................10

User’s manual
1
1. Safety instructions
Before installing and using products, please read the following carefully. The
company shall not be responsible for any loss caused by any breach of safety.
The output of the laser and erbium-doped fiber amplifier is high-power invisible
radiation. When the device works, it must not look directly at its connecting ends, so
as to avoid burns to the eyes and skin.
The device contains precision optical devices to avoid damage caused by severe
impact. Avoid severe vibration and collision. The tail fiber is easily damaged. Please
operate carefully.
The device contains electrostatic sensitive devices. Please be careful to operate
and ensure good grounding and normal power supply.
It is best to use AC voltage stabilizer to supply power in areas with unstable grid
voltage or poor voltage waveforms.
Special attention to optical fiber connector:
before using device, please make sure that the connector of the input and output
tail fiber is kept clean, especially if the output fiber connector has dirty goods, it
is easy to burn out output tail fiber and make the output optical power become
smaller. When cleaning the optical fiber end or inserting optical jumper, please
shut down the input light first. If you use alcohol to clean the fiber end, only it is
completely dry, you can connect fiber to use.
the correct order of plugging and unplugging is: for plugging optical fiber, first
inserting the output optical fiber and then inserting the input optical fiber. For
unplugging optical fiber, first pulling out input optical fiber, and then pulling
out the output optical fiber..
this EDFA is a high precision and high stability product. In order to make the
output power have high stability, please use excellent quality optical fiber . In
principle, the optical fiber should be as short as possible, and do not allow the
optical fiber to move random.
When the EDFA is not used, if there is no active cable connector connected to the

User’s manual
2
input and output optical port of EDFA, please cover dust-proof cap to prevent the
input and output end from being contaminated.
2. Production structure description
2.1 Equipment dimension
Adopting the 19" standard 1U chassis: 485mm (length) X298.13mm (width)
X44mm (height). As shown in the following figure:
2.2 The front panel diagram
OPT OUT OPT IN RS232 LED PWR NEXT ON/OFF
2.3 The rear panel diagram
ETH
ALARM ENTER

User’s manual
3
3. Operation instructions
To ensure the normal operation of EDFA, you must operate in accordance with
the following methods:
3.1 Connection
Ensure that the device is well grounded;
Measure input optical power, confirm within the EDFA input optical power
range, check the input and output optical fiber connector whether is
consistent with EDFA optical interface connector, and cleaning the connector
ends;
Connect input and output optical fiber.
3.2 Turn on/off procedure
when key switch is closed, plugging the power line of rear panel, turning on
power switch, at this time, the LCD screen is on and LED indicator displays
green. After a moment, turn on key switch, Preheating 5-10 minutes, and
EDFA enters the normal working state.
The sequence of shutting down is opposite to the starting order. Firstly , turn
off key switch, secondly, turn off power ,and unplug power line.
3.3 LED indicator description
The front panel LED indicator shows the following contents:
Power Indicator
When connecting power, green LED is on.
Alarm state display
When normal working, alarm led should turn off. After turn off pump laser,
alarm led flash red(including key switch shutting down and all kinds of
alarm state. Example for: input optical power below -5dBm)
Alarm indicator

User’s manual
4
Various alarm status LED flash red lights.
Remote monitor and control
When the external computer and EDFA are connected, you can view the
working parameters of the device through the Web page. First, input the
192.168.1.100 (default IP address) in the browser's address bar, second, click
the “enter”, and enter the login page to input the default username "admin",
and the password "admin".
3.4 Button description
NEXT
Pressing this button can view EDFA all kinds parameters from top to bottom.
When modified parameters, this button is downward value.
ENTER
Enter next level sub-menu, when finishing modifying, please press this
button to confirm change.
3.5 Display menu description
Display device manufacturer and model on power. The backlight of the LED
screen will be dimmed automatically to maintain the current display information
when any state keeps more than 60 seconds without being pushed. Press the “NEXT”
button, and the backlight of LED screen will be turned on and displayed ①this a
page. Press the”ENTER”button, the LED screen will be turned on and the current
display information will be maintained.
①Display device manufacture and model.As shown below:
E
D
F
A
H
F
3
0
0
-
3
8
1
5
C
-
2
2
D
Press “NEXT” button, then jump ②to display.
②Display input optical power interface. If input optical power is normal, as
shown below:

User’s manual
5
I
N
P
U
T
P
W
R
1
0
.
0
0
d
B
m
If input optical power is below -15.00dBm, the second line can display “NO
INPUT”
I
N
P
U
T
P
W
R
N
O
I
N
P
U
T
Press “NEXT” button, then jump ③to display.
③Display output optical power interface. If output optical power is normal, as
shown below:
O
U
T
P
U
T
P
W
R
2
2
.
0
0
d
B
m
If output optical power is below -7.00dBm, the second line can display “NO
INPUT”
O
U
T
P
U
T
P
W
R
N
O
O
U
T
P
U
T
If output optical power is normal, press “ENTER”button, then enter output
optical power setting interface, as shown below:
S
E
T
U
P
O
U
T
P
U
T
P
W
R
2
2
.
0
0
d
B
m
Press “NEXT”button, output optical power increases 0.10dbm each time, default
setting range is from 19.00 to 24.00dBm(modifiable). when more than max value, it
will change into min value. Press “ENTER”button in the output optical power
interface, exiting this interface and saving setting value.
Press “NEXT”button in output optical power interface, then jump ④to display.
④Display laser bias current interface, as shown below:

User’s manual
6
L
D
C
U
R
R
E
N
T
1
0
0
0
.
0
m
A
Press “NEXT”button, jump ⑤to display.
⑤Display TEC refrigeration / thermal current interface, as shown below:
T
E
C
C
U
R
R
E
N
T
0
.
2
0
A
Press “NEXT”button, jump ⑥to display.
⑥Display laser temperature interface, as shown below:
L
D
T
E
M
P
E
R
A
T
U
R
E
2
5
.
0
°
C
Press “NEXT”button, jump ⑦to display
⑦Display alarm list interface. When no alarm, as shown below:
A
L
A
R
M
L
I
S
T
N
o
n
e
when appearing alarm information, the display priority is displayed in the
following order from high to low (1. laser key off; 2. input optical power alarm,
mainly included into HIHI, HI, LO, LOLO; 3. output optical power alarm, mainly
included into HIHI, HI, LO, LOLO; 4. power alarm, mainly included into HIHI, HI,
LO, LOLO). When a variety of alarm appears, you can switch the next alarm by
pressing “ENTER”button. (laser key off alarm and output optical power alarm will
not appear at the same time).
L
A
S
E
R
K
E
Y
O
F
F
I
N
P
U
T
P
W
R
A
L
A
R
M
H
I
H
I
O
U
T
P
U
T
P
W
R
A
L
A
R
M
L
O
L
O

User’s manual
7
P
W
R
A
L
A
R
M
L
O
Press “NEXT”button, jump ⑧to display.
⑧Display Internal temperature of the chassis interface, as shown below:
I
N
T
E
R
T
E
M
P
E
R
A
T
U
R
E
T
2
5
.
0
°
C
Press “NEXT”button, jump ⑨to display.
⑨Display power supply information interface. As shown below, when only
left power working normal , displaying “PWR1”; when only right power working
normal , displaying “PWR2”,and two powers all working normal, displaying
“BOTH”(The power near the side shell is "PWR2").
P
W
R
S
T
A
T
U
S
P
W
R
1
Press “NEXT”button, jump ⑩to display.
⑩Display 3.5V voltage detection interface, as shown below:
3
.
5
V
P
W
R
3
.
5
V
Press “NEXT”button, jump ⑪to display.
11 Display 5.0V voltage detection interface, as shown below:
5
.
0
V
P
W
R
5
.
0
V
Press “NEXT”button, jump ⑫to display
12 Display serial number code interface, as shown below:
S
e
r
i
a
l
N
u
m
b
e
r
X
X
X
X
X
X
X
X
X
X
X
X
X

User’s manual
8
Press “NEXT”button, jump ⑬to display.
13 Display manufacture date interface, as shown below:
M
a
n
u
f
a
c
t
u
r
e
D
a
t
e
X
X
/
X
X
/
X
X
Press “NEXT”button, jump ⑭to display.
14 Display online time, as shown below:
O
n
l
i
n
e
T
i
m
e
x
x
x
x
D
a
y
s
x
x
H
o
u
r
s
Press “NEXT”button, jump ⑮to display.
15 Display IP address interface, as shown below:
I
P
A
D
D
R
1
9
2
.
1
6
8
.
0
0
1
.
1
0
0
Press “NEXT”button, jump ⑯to display.
Press “ENTER”button, enter IP address setting interface. Current modified bit
will flash.
S
E
T
U
P
I
P
A
D
D
R
1
9
2
.
1
6
8
.
0
0
1
.
1
0
0
S
E
T
U
P
I
P
A
D
D
R
9
2
.
1
6
8
.
0
0
1
.
1
0
0
Press “NEXT”button, It can be circulate to increase the value of the current bit
(0-9).
Press “ENTER”button, It can jump the next modified bit.
When switching the final bit, then pressing “ENTER”button, thus returning IP
address interface.
16 Display subnet mask interface, as shown below:

User’s manual
9
M
A
S
K
A
D
D
R
2
5
5
.
2
5
5
.
2
5
5
.
0
0
0
Press “NEXT”button, jump ⑰to display.
Press “ENTER”button, enter subnet mask setting interface. Current modified bit
will flash.
S
E
T
U
P
M
A
S
K
A
D
D
R
2
5
5
.
2
5
5
.
2
5
5
.
0
0
0
S
E
T
U
P
M
A
S
K
A
D
D
R
5
5
.
2
5
5
.
2
5
5
.
0
0
0
Press “NEXT”button, It can be circulate to increase the value of the current bit
(0-9).
Press “ENTER”button, It can jump the next modified bit.
When switching the final bit, then pressing “ENTER”button, thus returning
subnet mask interface.
17 Display gateway address interface, as shown below:
G
A
T
E
W
A
Y
A
D
D
R
1
9
2
.
1
6
8
.
0
0
1
.
0
0
1
Press “NEXT”button, jump ⑱to display.
Press “ENTER”button, enter gateway address setting interface. Current
modified bit will flash.
S
E
T
U
P
G
A
T
E
W
A
Y
A
D
D
R
1
9
2
.
1
6
8
.
0
0
1
.
0
0
1
S
E
T
U
P
G
A
T
E
W
A
Y
A
D
D
R
9
2
.
1
6
8
.
0
0
1
.
0
0
1
Press “Next”button, It can be circulate to increase the value of the current bit
(0-9).
Press “ENTER”button, It can jump the next modified bit.
When switching the final bit, then pressing “ENTER”button, thus returning
gateway address interface.

User’s manual
10
18 Display restore factory setting interface, as shown below:
R
E
S
T
O
R
E
F
A
C
T
O
R
Y
C
O
N
F
I
R
M
Press “ENTER”button, jump ①to display.
Press “ENTER”button, enter restore factory confirm interface.
C
A
N
C
E
L
A
F
F
I
R
M
Press “NEXT”button, cancel restore factory setting, and jump to restore factory
setting interface.
Press “NEXT”button, confirm restore factory setting. First displaying restore
factory setting success, then pressing“ENTER”button to jump restore factory setting
interface.
R
E
S
T
O
R
E
F
A
C
T
O
R
Y
S
U
C
C
E
S
S
4. Alarm breakdown analysis
Alarm
Possible cause
Pre-warranty check
Pin<input optical power
threshold, no input
optical power alarm
1. Optical transmitter no optical
output
2. Input optical fiber connector is
not connected well
3. Connector end face damaged
4. EDFA damaged
1. Check input optical
power by optical power
meter
2. Clean input optical
connector
3. Re-plug optical
connector
Pout<output optical
power threshold, no
input optical power
alarm
1. Pump don’t turn on switch
2. Input optical wavelength not
within 1530nm-1560nm
3. EDFA damaged
1. Check pump switch
whether is on state
2. Check input optical
wavelength whether is
within 1550nm-1560nm
3. Check environment
temperature whether is too
high causing pump off
automatically

User’s manual
11
Pump current change a
lot, pump current alarm
1. Pump laser characteristic change
2. Internal circuit detection
deviation
3. Pump laser damaged
1. Check environment
temperature is too high.
The working temperature
of chassis is within
0-50℃. Usually, when the
ventilation is not good, the
temperature inside the
chassis is much higher
than environment
temperature.
2. Check the chassis Heat
dissipation ventilation
environment whether is
good.
3. Whether the ventilation
holes are blocked on both
sides of the chassis.
4. Whether the EDFA is
placed between the
equipment with the heat
source up and down, and
the distance of the
equipment is less than
20mm.
Pump output optical
power decreases, output
optical power alarm
1. Internal circuit detection
deviation
2. Pump laser degradation
3. Pump laser damaged
Pump laser refrigeration
current high, TEC
current alarm
1. EDFA environment temperature
too high
2. Pump laser refrigeration is
invalid
3. Pump laser damaged
Pump laser temperature
high, pump temperature
alarm
1. environment temperature too
high
2. Pump laser refrigeration is
invalid
Table of contents
Other C-Data Amplifier manuals