Dr. Mach Stand foot User manual

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 1/11
Mounting instructions Directions for use
STAND FOOT – STAND TUBE
Stand lamps: Makrolux
Mach 115
Mach 120 / Mach 120F
Dr. Mach GmbH u. Co., Flossmannstrasse 28, D-85560 Ebersberg
Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50
Internet: www.dr-mach.com, E-mail: [email protected]

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 2/11
List of contents
1. Safety instructions ....................................................................................Page 3
2. Installation summary – stand lamps..........................................................Page 4
3. Overview table ..........................................................................................Page 5
Stand foot, stand tube, swivel arm
4. Mounting instructions................................................................................Page 6
4.1 Mounting the stand foot ......................................................................Page 6
5. Directions for use......................................................................................Page 7
5.1 Stand foot ...........................................................................................Page 7
5.2 Stand tube ..........................................................................................Page 7
5.3 Swivel arm ..........................................................................................Page 8
6. Cleaning....................................................................................................Page 8
7. Maintenance .............................................................................................Page 8
8. Data ..........................................................................................................Page 9
9. Disposal ....................................................................................................Page 9
10. Spare parts .............................................................................................Page 10
10.1 Stand foot .........................................................................................Page 10
10.2 Stand tube and swivel arm ...............................................................Page 11

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 3/11
1. Safety instructions
The stand foot may not be connected to the mains until it has been fully assembled and in-
stalled.
The manufacturer is only responsible for operational safety of the stand foot when repairs and
modifications are carried out by his own staff or by persons who guarantee compliance with
the safety regulations.
The manufacturer is not responsible for damage to persons or property caused by incorrect or
improper use, or when used for incorrect purposes.
General information
These installation instructions must be kept on the lamp together with the relevant
operating instructions for consultation at any time.
All Dr. Mach stand lamps are supplied with all
installation and connection parts and compo-
nents.
For packaging reasons, the five-foot stand is
supplied in dismantled state. The stand tube is
always assembled as a unit and only needs to be
attached to the foot with the lower fastening
screw.
The lamp is supplied with integrated connection
lead and earthed plug.
The socket to be used for the lamp must be in-
stalled according to the requirements stipulated
by the IEC or VDE 0107.
Please check that the earthed socket is available
within the working area of the lamp.

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 4/11
2. Installation summary – stand lamps
Example: Lamp Mach 120
The stand is adjustable in heihgt and is to be mounted with the lamps Makrolux, Mach 115 and Mach
120/120F. The stand is not electrified.

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 5/11
3. Overview table
Stand foot – stand tube – swivel arm
Lamp type
Data
Makrolux Mach 115 Mach 120/120F
Primary 230V AC (120V AC optional)
Secondary 24V
Power
supply
Transformer 20W 39W 40W
Number of
extension arms 5
Length of extension
arm 310mm
Stand foot
Roller ∅50mm
Length approx. 95cm – 145cm
Diameter 25mm
Extension yes
Cable connection no
Stand tube
Suitable for
article no.
1100 1012 00
1101 1012 00 1151 1012 00 1201 1012 00
1202 2012 00
Swivel arm +
lamp head Mounting • Swivel arm and lamp head premounted
• Swivel arm to stand

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 6/11
4. Mounting instructions
Extent of supply
• 1x 5-footed plastic central base
• 2x extension arms with blocking rollers
• 2x extension arms with electrically conductive rollers
• 1x extension arm with roller
• 1x cam catch plate
• 1x cheese head screw M8 with lock washer
• 1x stand tube
• Lamp head with arm
• Mounting instructions/Instructions for use – stand
• Instructions for use – lamp head
4.1 Mounting the stand
For mounting the stand proceed as follows:
• Place the central base 1onto the stand tube
∅25 2. The stiffness is to ensure a tight fit that
is free from any movement.
• Pre-mount the cam catch plate 3(cams point
inwards), with the lock washer 4and cheese
head screw M8 5, so that the extension arm 6
can still fit easily into the central base. Insert
the extension arm 6into the central base from
above holding the cam catch plate 3against
from the opposite side.
• Insert the other 4 extension arms 7-10 in the
sequence shown in the left figure into the cen-
tral base. The extension arms are held by the
cams of the cam catch plates.
Remark: Mount the two locking rollers 11 and
12, and the two electrically conductive rollers 13
and 14 as shown in the figure (not next to each
other).
• Tighten the catch plate with an Allen key SW6
(approx. 15Nm).
The cams of the catch plate must mate with the
drill holes of the extension arms so that every
extension arm is tightly fitted to both the central
base and stand tube.
The cams also prevent the extension arms from
being pulled out.
2
14
9
10 12
1
6 8
13 7
11 3 4 5

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 7/11
5. Directions for use
5.1 Foot
The five-foot stand is equipped with two opposing
braked wheels A.
Set the brake by pressing the pedal Son the roller.
Unlock by lifting the pedal again.
A
S
S
A
5.2 Stand tube
The stand tube can be adjusted continuously in
height and fixed in the precisely required position,
needing only one hand.
The height is adjusted by lifting the slip button 15.
The position is automatically fixed on letting go.
As long as the slip button 15 is raised, the exten-
sion tube can be pulled off or inserted into the stand
tube.
15

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 8/11
5.3 Swivel arm
The swivel arm with transformer as counterweight is
in balance, when the lamp is inserted in position.
Adjust the moving of the swivel arm with the adjusting
lever 16.
• The swivel arm doesn’t hold its set position:
Turn the adjusting lever clockwise as far as nec-
essary (I.). You can fix the lamp in the required
position.
• The swivel arm moves sluggishly:
Turn the adjusting lever anti-clockwise (II.), until
you can move the swivel arm easy enough.
The adjusting lever can be brought into a suitable
position by pulling it out, without changing the ad-
justed clamping force.
II.
I.
16
6. Cleaning
The surface of the stands can be easily kept clean
by simply wiping with a damp cloth. You can use
conventional cleaning agents.
In case of disinfection only use disinfectants with
less than 20% alcohol.
Remark: For cleaning the lamp head, the dis-
persion lenses and splinter protection disks,
see respective instructions for use of the lamp.
Alc. ≤20 %
7. Maintenance
Caution!
The mains plug must be disconnected before performing any maintenance work.
The mounting journal Mand the journal groove of
the lamp should be lightly greased with acid-free
grease when mounting the lamp and once in a
year.
M

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 9/11
8. Data
Environmental conditions
Operation
Min.
Max.
Temperature +10°C +40°C
Relative atmospheric humidity 30% 75%
Air pressure 700 hPa 1060 hPa
Transport / storage
Min.
Max.
Temperature -10°C +50°C
Relative atmospheric humidity 20% 90%
Air pressure 700 hPa 1060 hPa
9. Disposal
The stands do not contain any danger goods.
The components of the stand should be properly disposed at the end of its shelf life.
Make sure that the materials are carefully separated.
The components of the stand should be disposed according to the contained materials.

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 10/11
10. Spare parts
Item
Qty.
Name
EDVNO
Remarks
01 1 Central base
02 1
Stand tube ∅25mm
03 1 Cam catch plate
04 1 Lock washer
05 1 Cheese head screw M5
06
07
08
09
10
5 Extension arm length 300mm
11
12 2 Roller ∅50mm with brake
13
14 2 Roller ∅50mm electrically conductive
15 1 Slip button Extension tube
16 1 Adjusting lever Swivel arm
10.1 Stand foot
14
13
12
11
10 09
08
07
06
01
02
03 04 05

Stand foot Dr. Mach
Lamps and Engineering
Edition 01 03.02.2000 / Bak Page 11/11
10.2 Stand tube and swivel arm
1
165
Table of contents
Popular Rack & Stand manuals by other brands

B-Tech
B-Tech BT8702 installation guide

Fromm&Starck
Fromm&Starck STAR ATFE 11 user manual

New Star
New Star Neomounts FPMA-D850BLACK instruction manual

Connect IT
Connect IT CMF-3207-BK user manual

thermastor
thermastor 4037766 installation manual

New Star
New Star Neomounts FPMA-C400SILVER instruction manual