Fujitsu ETERNUS DX100 S3 User manual

Setup Guide
Setup Guide
FUJITSU Storage
ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems
P3AM-7852-06ENZ0
An installation space and network environment must be prepared in advance.
Prepare the following manuals:
●Manuals for the ETERNUS DX100 S3/DX200 S3
●Related manuals, such as manuals for the server or the networking equipment that is used
Installation Space
Site Planning Guide
Network Environment
•Configuration Guide (Basic)
•Configuration Guide (Web GUI)
Preparation
STEP
Installation space
Check that the installation area meets the space requirements of the rack in which the ETERNUS DX is to be
installed.
Environmental considerations for installation
Check if the installation area for the ETERNUS DX meets the environmental conditions and installation environment
conditions.
Power outlets
Check the type and the number of power outlets/sockets that are required to install the ETERNUS DX.
Completing and attaching the Network Settings label
Write down the IP address for the ETERNUS DX on the Network Settings label and attach it inside the rack.
Settings for the PC
●Set up the network environment
-IP address : 192.168.1.2
-Subnet mask : 255.255.255.0
●Set the Web browser
Refer to "Configuration Guide (Web GUI)" for details on the settings that are required.

2
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
The rack rail needs to be attached to the rack and the controller enclosure or the drive enclosure needs to be
installed.
Installation in a Rack
STEP
Configuration Guide (Basic)
Controller Enclosures and Drive Enclosures (2.5" type/3.5" type)
●Drive enclosures must be installed above
the controller enclosure. When installing
multiple drive enclosures, install them in the
order of the "DE_No. label" numbers that are
attached to the drive enclosures.
The DE_No. labels are attached on the
locations that are shown in the figure on the
right.
●The center of gravity must be taken into
consideration to prevent a rack from toppling
over. The controller enclosure and drive
enclosures should generally be installed from
bottom to top to lower the center of gravity
and to ensure the safe use of racks.
IMPORTANT
DE_No. labels
DE_No. labels
Right front side
of the drive enclosure (2.5” type/3.5” type)
Upper rear side
of the drive enclosure (2.5” type/3.5” type)
Right front side
of the high-density drive enclosure
Upper rear side
of the high-density drive enclosure
1. Attach the rack rails to the rack.
The size of the controller enclosure and each drive enclosure is 2U.
(Front rack pillars)
(Rear rack pillars)
Rack rail (for right side)
Rack rail (for left side)
Washers
M5 screws
M5 screws
Washers
M5 screws
Plate
M5 screws
Plate

3
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
M5 screws
M5 screws
Flange cover
Flange cover
●To fasten the controller enclosure
Use three M5 screws to fasten the controller enclosure to the rack pillars and attach the flange cover.
●To fasten the drive enclosure
Use four M5 screws to fasten the drive enclosure to the rack pillars and attach the flange cover.
M5 screws
Flange cover
M5 screws
Flange cover
2. Install and fasten the controller enclosure or the drive enclosure in the rack.
Make sure to install or remove the controller enclosure or the drive enclosure in the rack with two or more
people.
IMPORTANT

4
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
High-density Drive Enclosures
1. Attach the rack rails to the rack.
The size of a high-density drive enclosure is 4U.
2. Install the stopper brackets (for the left and right sides) in the front, and then install the flap brackets in
the rear.
●Rack pillar: front
●Rack pillar: rear
Stopper bracket
(left)
(Rack pillar: front)
Rack rail
(right)
Rack rail
(left)
M5 screw
M5 screw
Stopper bracket
(right)
M4 screw
(Rack pillar: rear)
Rack rail
(left)
Rack rail
(right)
Flap bracket A
Flap bracket B

5
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
Various cables need to be connected to the ports on the rear of the ETERNUS DX.
Cable Connection
STEP
●To help with cable management and prevent incorrect connection, attach labels to the cables and make a
note of connection origins and destinations.
●This step describes dual controller type as an example. Note that there is only controller 0 (CM#0) for single
controller type.
Point
●The cables should never be bent, twisted or pulled.
●Some cables have static-sensitive electronic components. Wear an anti-static wrist strap or touch a metal
part to discharge the static electricity on your body before starting each operation. Failure to discharge static
electricity before touching the connectors may cause a device failure.
IMPORTANT
Configuration Guide (Basic)
3. Install and fasten the high-density drive enclosure in the rack, and then attach the front cover.
Attach the cable management arm in the rear.
For safety and stability, use a lifter to install or remove high-density drive enclosures in the rack.
IMPORTANT
Front cover
(Rack pillar: front)
(Rack pillar: rear)
M5 screws
M5 screws
Cable
management arm
Pin

6
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
●FC,
iSCSI 10Gbit/s (10GBASE-SR),
FCoE,
Ethernet 10Gbit/s
(for FC cable connection)
●iSCSI 10Gbit/s (10GBASE-T),
iSCSI 1Gbit/s,
Ethernet 1Gbit/s
●SAS
Connect a Host Interface cable to each of these ports.
Rear viewCable
●iSCSI 10Gbit/s (10GBASE-SR),
FCoE,
Ethernet 10Gbit/s
(for Copper Twinax cable
connection)
Controller enclosure
CA#0 CA#1 CA#0 CA#1
iSCSI 10Gbit/s (10GBASE-T),
iSCSI 1Gbit/s
Port#0 Port#1
SAS
Port#0 Port#1
Port#0 Port#1
FC, iSCSI 10Gbit/s (10GBASE-SR),
FCoE, Ethernet 10Gbit/s
(for FC cable connection)
Port#0 Port#1
iSCSI 10Gbit/s (10GBASE-SR),
FCoE, Ethernet 10Gbit/s
(for Copper Twinax cable connection)
Ethernet 1Gbit/s
Port#0 Port#1 Port#2 Port#3
Host Interface Cable
2
CA#1 CA#0 CA#1 CA#0
Controller enclosure
Rear viewCable
●MNT port
A port that is used to connect to an operation management LAN. Before connecting to the operation
management LAN, change the IP address of the MNT port in the Setup Network Environment settings.
●RMT port
A port that is used for initial setup or to connect to the remote support center.
Controller (CM#0) Controller (CM#1)
MNT por
tM
NT port
Controller enclosure
RMT port RMT port
LAN Cable
1

7
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
DI (OUT) portDI (IN) port
●DI (OUT) side plug
●DI (IN) side plug
Rear viewCable
Attach the destination labels
to the plugs of the mini SAS HD
cables between enclosures.
When drive enclosures are installed, use mini SAS HD cables between enclosures to connect between the DI ports of
each enclosure.
●Controller enclosure
●Drive enclosure
●Example of mini SAS HD cable connections between enclosures
(when two drive enclosures are installed)
Between Controller 0 and I/O module line 0, connect the drive enclosures
in ascending order of the drive enclosure numbers.
Between Controller 1 and I/O module line 1, connect the drive enclosures
in descending order of the drive enclosure numbers.
The DI (IN) port is on the left side and the DI (OUT) port is on
the right side of each I/O module.
Plug the connectors on which the " " symbol is printed into
the DI (IN) ports.
Plug the connectors on which the " " symbol is printed into
the DI (OUT) ports.
The " ■" symbol is
printed here.
The "●" symbol is
printed here.
DI (OUT) port
The controller enclosure only has DI (OUT) ports.
Connect the connectors on which the " " symbol is printed.
Controller enclosure
Drive enclosure 2
Drive enclosure 1
Mini SAS HD Cable Between Enclosures
3
When connecting the mini SAS HD cable between enclosures,
check the direction of the connector (the tab must be pointed
downward) and firmly insert all the way in.
IMPORTANT
Tab

8
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
Connect the power cords to the inlets of the power supply unit.
Use release ties to hold the power cords in place.
Rear viewCable
Drive enclosure
Controller enclosure
Power Cords
4
Use ETERNUS Web GUI to perform a basic setup of the ETERNUS DX.
Connect a PC terminal to the ETERNUS DX.
Connect the PC terminal to the RMT port of Controller 0 (CM#0) on the controller enclosure directly with the LAN
cable.
Turn on the PC terminal and the ETERNUS DX.
PC terminal
LAN cable
LAN port
Controller enclosure
RMT port of Controller 0 (CM #0)
Basic Setup
STEP
Configuration Guide (Basic)
Controller enclosure
Power switch
Drive enclosure
ETERNUS DX and PC Terminal Connection
1
Powering On
2

9
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
Perform the settings that are required before operation of the ETERNUS DX on the Initial Setup screen.
Perform the following settings according to the wizard
screen:
●Set Storage System Name
●Change User Password
●Set Thin Provisioning
●Register SED Authentication Key
●Setup Network Environment
In the Setup Network Environment settings, set the IP
address of the MNT port to connect the ETERNUS DX to
the operation management LAN.
1. Open the Web browser on the PC terminal.
2. Enter the following URL in the address bar of the Web
browser.
http://192.168.1.1/
The login screen for ETERNUS Web GUI appears.
3. To change the user interface language, click the
[Option] button and select "English" or "Japanese" in
"Language".
4. Enter the username and password.
Username: root
Password: root (by default)
ETERNUS Web GUI Startup
3
Initial Setup
4
After logging in, the Initial Setup screen of ETERNUS Web GUI appears.
After the settings are complete, close the Web browser.
Make sure to set up the network
environment for the MNT port.
If the network environment for the MNT
port is not set up, some functions will be
unusable.
IMPORTANT

10
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
Remove the LAN cable between the RMT port on Controller 0 and the PC terminal.
Connect the LAN cables of the MNT ports on Controller 0 and Controller 1 to the network of the customer.
Then start the web browser from the PC terminal that is connected to the network and log in to ETERNUS Web GUI
again with the IP address that is set in the Setup Network Environment settings. After login, the Overview screen
appears.
Establishing a Connection between the ETERNUS DX and the Operation Management LAN
5
Set the firewall for each service.
Firewall Settings
6
1. Click the [System] tab, click [Network] in [Category],
and then click [Setup Firewall] in [Action].
2. Enable or disable each service.
If the network environment for the MNT
port is not set up, some functions will be
unusable. Make sure to set up the network
environment.
IMPORTANT

11
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
Use ETERNUS Web GUI to set RAID configurations in the ETERNUS DX.
Perform the following settings:
●RAID group creation
●Volume creation
●Hot spare registration
1. RAID group creation
Create RAID groups to create volumes.
To display the screen to create RAID groups:
Click the [RAID Group] tab, and then click [Create]
in [Action].
2. Volume creation
Create volumes in the RAID group.
To display the screen to create volumes:
Click the [Volume] tab, and then click [Create] in
[Action].
3. Hot spare registration
Register the hot spare for the failure of a drive.
To display the screen to register the hot spare:
Click the [Component] tab, and then click [Drives] in [Category].
●Global Hot Spare registration
Select the drive that is to be registered as the
Global Hot Spare and click [Assign Global HS] in
[Action]. In the confirmation screen that appears,
click the [OK] button.
●Dedicated Hot Spare registration
Select the drive that is to be registered as the
Dedicated Hot Spare and click
[Assign Dedicated HS] in [Action].
RAID Configuration Settings
7
Select which RAID group to use the selected drive
as a Dedicated Hot Spare for and click the [Assign]
button. In the confirmation screen that appears,
click the [OK] button.

12
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
The host affinity settings ensure security when multiple servers are connected by assigning the host interface ports
that the hosts (servers) can access and the volumes that the hosts (servers) can recognize.
Follow the procedure below to set host affinity by associating a host group, a CA port group and a LUN group.
1. Host group addition
Add the information on the hosts (servers) that access
the ETERNUS DX.
To display the screen to add the host groups (example
for iSCSI host groups):
Click the [Connectivity] tab, click [Host Group] in
[Category], and then click [Add iSCSI Host Group] in
[Action].
2. Port parameter settings
Set the connection information between the host
interface port and the server.
To display the screen to set the port parameters
(example for iSCSI Port):
Click the [Connectivity] tab, and then click [iSCSI]
under [Port Group] in [Category]. Select the checkbox
for the iSCSI port to set the port parameters for on the
[iSCSI Port] screen and then click [Configure iSCSI Port]
in [Action].
3. Port group creation
Create a port group for a host to access the ETERNUS
DX.
To display the screen to create a port group (example
for iSCSI Port):
Click the [Connectivity] tab, click [Port Group] in
[Category], and then click [Create iSCSI Port Group] in
[Action].
4. LUN group addition
Add a group of volumes that can be recognized by the
host (LUN group).
To display the screen to add a LUN group:
Click the [Connectivity] tab, click [LUN Group] in
[Category], and then click [Add LUN Group] in [Action].
Host Affinity Settings
8

13
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
5. Host affinity creation
Create an association between a host group and a port
group and an association between a host group and a
LUN group.
To display the screen to create a host affinity:
Click the [Connectivity] tab, and then click [Create Host
Affinity] in [Action].
Perform the ETERNUS DX monitoring setup if required.
●Notification of the ETERNUS DX problems as they occur is possible if the event notification method and level
have been set.
●If remote support is required, the ETERNUS DX needs to be set to notify the remote support center of failures.
Perform the settings required to connect to the server and install the required drivers. Perform the settings required
for network devices connecting the server and the ETERNUS DX.
After the server connection setup, confirm that the volumes in the ETERNUS DX can be recognized by the server.
All necessary settings are complete, and the ETERNUS DX is now ready for normal operation.
Monitoring Setup
STEP
Server Connection
STEP
Remote support allows prompt detection and resolution of trouble.
Point
Configuration Guide (Basic)
•Configuration Guide (Basic)
•Configuration Guide -Server Connection-

14
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0
•The content of this manual is subject to change without notice.
•This manual was prepared with the utmost attention to detail.
However, Fujitsu shall assume no responsibility for any operational
problems as the result of errors, omissions, or the use of
information in this manual.
•Fujitsu assumes no liability for damages to third party copyrights
or other rights arising from the use of any information in this
manual.
•The content of this manual may not be reproduced or distributed in
part or in its entirety without prior permission from Fujitsu.
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems
Setup Guide
P3AM-7852-06ENZ0
Date of issuance: April 2017
Issuance responsibility: FUJITSU LIMITED
Operation and Maintenance
Status check
The status of the ETERNUS DX should be regularly monitored by checking the LEDs and using ETERNUS Web GUI.
Data backup
Important data should be regularly backed up to a tape drive or similar device as a precaution against system failures.
Maintenance support period
The standard maintenance support period for ETERNUS DX is five years from the date of purchase, or is defined in your service
level agreement (SLA). Contact your sales representative for details if you prefer to extend the period.
Operation Guide (Basic)
Other manuals for ETERNUS DX100 S3
4
This manual suits for next models
1