6. Tighten the screws to secure the wires to the terminal block, part number PUFP-
TN.
7. Excess wire should be pushed out of the box or made to be as flat as possible on
the bottom of the PUFP-PB box. Failure to push the wire out of the box or make
it flat in the box will interfere with the opening mechanism and the unit will
not be able to pop open.
8. Remove the protective film from the PUFP-CT cover and press the oval button on
the PUFP-CT cover exposing the two mounting screw holes inside the cover.
9. Place the PUFP-CT cover on top of the PUFP-PB box. Line up the two screw holes
with the PUFP-CT cover and the PUFP-PB box and using the 2 provided screws,
secure the cover to the box (do not over tighten as this may strip the threads in the
box and interfere with the opening mechanism of the box.)
9. Place the box with cover assembled into the hole in the top of the countertop.
10. Place the locking ring onto the bottom of the PUFP-PB box and screw the locking
ring up until the flanged portion is butted tight against the underside of the counter
top. The box is fully secured to the countertop when there is no movement of the
box within the hole.
11. Open and close the unit several times to make sure that the unit is opening
properly. All units are preset to the optimal functioning speed at the factory before
they are shipped.
OPERATING INSTRUCTIONS
1.To open cover and expose receptacle, press and hold the oval button until the lid
has reached maximum height.
2. To close the cover, press and hold the oval button while pressing down on the
cover until you hear a click, then the unit is locked into place.
■ Never use in overload situation, or it may increase the risk of catching a fire.
Ne jamais utiliser en situation de surcharge, ou cela peut augmenter le risque de provoquer un incendie.
■ Make sure that all bare wire is connected deeply and securely into the terminal(see diagram). Failure to do so will
increase the risk of fire.
Veiller à ce que tous les fils nus solent connécte profondément et solidement dans le bornier (voir schéma).
A défaut, cela augmente le risque d'incendie.
■ Once the wiring connections are made wrap the connections with U.L. approved electrical tape. Failure to do so will
increase the risk of causing a fire.
Une fois les branchements faits, enrouler de l'adhésif agrééU.L. autour des connexions.
A dédaut, cela augmente le risque de provoquer un incendie.
■ The products should be installed by a licensed and bonded electrical contractor according to related USA
and Canadian Electrical Code.
Les produits doivent être installés par un électricien agréé et lié selon le Code électrique canadien en rapport
■ Never use a wiring device other than the U.L. listed wiring device provided.
Ne jamais utiliser un dispositive de câblage autre que le dispositive de câblage agréé U.L. fourni.