TECHNICAL GUIDE
80% MODULATING (PSC MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: LM8M / LMLM
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional efficiency rating information can
be found at www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
402697-LTG-B-1008
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
WARRANTY
Lifetime limited warranty on heat exchanger to the original pur-
chaser; a 20-year limited warranty from original installation date
to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applica-
tions.
5-year limited parts warranty.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower.
- Modulating operation from 100% input to 50% input in 1%
increments.
• Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement application.
• All models are convertable to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• 100% shut off main gas valve for extra safety.
• High-efficiency variable speed direct drive motor.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Blower door safety switch.
• Solid removable bottom panel allows easy conversion.
• Low NOx models have been designed to meet specific code
requirements.
• Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer, burner and blower operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Venting applications - may be installed as a common vent
with other gas-fired appliances.
• Insulated blower compartment for thermal and acoustic
performance.
• 1/4 turn knobs provided for easy door removal.
2Johnson Controls Unitary Products
402697-LTG-B-1008
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
LEFT SIDE RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
30.25”
28.5”
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models Nominal
CFM (m3/min) Cabinet
Size Cabinet Dimensions (Inches) Approximate
Operating Weights
A B C Lbs
LM(8,L)M060A12MP11 1200 A 14 1/2 13 1/4 10.3 94
LM(8,L)M080B12MP11 1200 B 17 1/2 16 1/4 11.8 103
LM(8,L)M080C16MP11 1600 C 21 19 3/4 13.6 114
LM(8,L)M100C16MP11 1600 C 21 19 3/4 13.6 118
LM(8,L)M100C20MP11 2000 C 21 19 3/4 13.6 122
LM(8,L)M120C20MP11 2000 C 21 19 3/4 15.8 129
Ratings & Physical / Electrical Data
Models Input
Max/Min Output
Max/Min AFUE Nominal
Airflow Total
Unit
Amps
Air Temp.
Rise Max
Input
Air Temp.
Rise Min
Input
MBH MBH CFM °F °F
LM(8,L)M060A12MP11 60/30 47/24 80.0 1200 7.0 35-65 20-50
LM(8,L)M080B12MP11 80/40 62/32 80.0 1200 7.5 40-70 20-50
LM(8,L)M080C16MP11 80/40 62/32 80.0 1600 10.0 40-70 20-50
LM(8,L)M100C16MP11 100/50 78/40 80.0 1600 10.0 40-70 20-50
LM(8,L)M100C20MP11 100/50 78/40 80.0 2000 17.0 35-65 20-50
LM(8,L)M120C20MP11 120/60 95/48 80.0 2000 17.0 45-75 25-55
Models
Max.
Outlet
Air Temp Blower Blower
Wheel
size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
°F HP Amps
LM(8,L)M060A12MP11 165 1/3 4.8 11 x 8 15 14
LM(8,L)M080B12MP11 170 1/3 4.8 11 x 8 15 14
LM(8,L)M080C16MP11 170 1/2 7.5 11 x 10 15 14
LM(8,L)M100C16MP11 170 1/2 7.5 11 x 10 15 14
LM(8,L)M100C20MP11 165 1 14.5 11 x 11 20 12
LM(8,L)M120C20MP11 175 1 14.5 11 x 11 20 12
402697-LTG-B-1008
Johnson Controls Unitary Products 3
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor-
mance” table represents blower performance WITHOUT filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabi-
net. DO NOT attempt to install any filters inside the furnace.
NOTE: Single side return above 1800 CFM is approved as long
as the filter velocity does not exceed filter manufacturer’s rec-
ommendation and a transition is used to allow use of a 20 x 25
filter.
NOTES:
1.Air velocity through throwaway type filters may not exceed 300 feet per
minute (91.4 m/min). All velocities over this require the use of high velocity
filters.
2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
ACCESSORIES
PROPANE (LP) CONVERSION KIT -
1NP0680 - All Models
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation.
SIDE RETURN FILTER RACKS -
1SR0200 - All Models
1SR0302 - All Models
1SF0101 - All Models
BOTTOM RETURN FILTER RACKS -
1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR05xx series are galvanized steel filter racks. 1BR06xx are
pre-painted steel filter racks to match the appearance of the fur-
nace cabinet.
COMBUSTIBLE FLOOR BASE KIT -
For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations. These kits
are also required in any applications where the furnace in
installed in a downflow configuration without an evaporator coil,
where the combustible floor base kit provides access for com-
bustible airflow.
1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
EAC TRANSITION KITS -
For installation of EAC accessories with these furnaces to pro-
vide easy transition of return airflow through the EAC to get the
proper sealing and reduced airflow leakage.
1TK1001 - For all models using side return
1TK1014 - For 14-1/2” cabinets using bottom return
1TK1017 - For 17-1/2” cabinets using bottom return
1TK1021 - For 21” cabinets using bottom return
1TK1024 - For 24-1/2” cabinets using bottom return
HIGH ALTITUDE - No high altitude kits are required.
ROOM THERMOSTATS - A wide selection of compatible ther-
mosets are available to provide optimum performance and fea-
tures for any installation.
1H/1C, manual change-over electronic non-programmable ther-
mostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the price
book or consult factory.
Recommended Filter Sizes
CFM Cabinet
Size Side
(in) Bottom
(in)
1200 A 16 x 25 14 x 25
1200 B 16 x 25 16 x 25
1600 C 16 x 25 20 x 25
2000 C (2) 16 x 25 20 x 25
Unit Clearances to Combustibles
Application Top Front Rear Left
Side Right
Side Flue Floor/
Bottom Closet Alcove Attic Line
Contact
UpflowB-Vent 130001CombustibleYesYesYes No
DownflowB-Vent130001 11
1. Special floor base or air conditioning coil required for use on floor.
Yes Yes Yes No
HorizontalB-Vent130001CombustibleNoYesYesYes2
2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building
joists, studs or framing.
Subject to change without notice. Printed in U.S.A. 402697-LTG-B-1008
Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 402697-LTG-A-0508
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
NOTES:
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Return air is through side opposite motor (left side).
3. Motor voltage at 115 V.
4. Airflow through across motor side (right side) may be slightly less than the data shown above.
Blower Performance CFM - Any Position
Bottom Airflow Return (SCFM) (without filter)
Models Speed Ext. Static Pressure (in. H2O)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LM(8,L)M060A12MP11
High 1358 1341 1319 1303 1275 1238 1190 1130 1062 943
Medium High 1097 1083 1075 1064 1042 1024 997 962 906 821
Medium Low 935 928 920 899 872 840 809 771 731 659
Low 800 779 763 736 711 687 657 622 584 529
LM(8,L)M080B12MP11
High 1320 1327 1307 1281 1243 1197 1143 1075 1003 881
Medium High 1003 981 975 954 926 895 865 824 751 687
Medium Low 821 818 809 786 758 726 690 631 594 534
Low 674 652 624 599 566 531 494 451 394 354
LM(8,L)M080C16MP11
High 1881 1822 1783 1696 1602 1539 1465 1394 1267 1130
Medium High 1553 1535 1492 1456 1408 1343 1279 1226 1113 1014
Medium Low 1312 1286 1288 1260 1205 1143 1091 1029 966 841
Low 1169 1166 1128 1098 1069 1032 987 909 835 747
LM(8,L)M100C16MP11
High 2069 2014 1956 1885 1820 1748 1668 1577 1468 1362
Medium High 1662 1656 1639 1608 1586 1544 1491 1421 1338 1204
Medium 1368 1371 1377 1376 1367 1334 1295 1250 1188 1104
Low 1016 1014 1018 1030 1012 996 975 944 898 852
LM(8,L)M100C20MP11
High 2764 2695 2618 2552 2432 2337 2228 2109 1954 1808
Medium High 2028 2009 1976 1910 1871 1830 1749 1679 1573 1473
Medium Low 1613 1600 1543 1533 1482 1433 1384 1316 1252 1160
Low 1297 1277 1245 1213 1175 1129 1077 1011 925 837
LM(8,L)M120C20MP11
High 2701 2620 2533 2429 2338 2227 2112 1993 1861 1706
Medium High 2125 2083 2046 1994 1955 1901 1857 1737 1621 1497
Medium Low 1664 1664 1547 1619 1580 1554 1468 1392 1331 1226
Low 1357 1339 1330 1318 1286 1235 1185 1141 1060 938
Left Side Airflow Return (SCFM) - Upflow (without filter)
LM(8,L)M060A12MP11
High 1244 1229 1226 1215 1196 1177 1143 1072 1015 940
Medium High 1129 1126 1107 1094 1076 1047 1010 966 921 843
Medium Low 970 947 933 916 890 863 827 789 741 668
Low 834 809 797 768 740 710 677 634 586 534
LM(8,L)M080B12MP11
High 1274 1285 1255 1239 1207 1158 1111 1049 979 830
Medium High 975 974 968 960 948 923 879 823 756 672
Medium Low 777 771 772 762 752 734 695 651 604 529
Low 647 634 623 610 602 588 552 506 457 381
LM(8,L)M080C16MP11
High 1825 1781 1746 1695 1641 1587 1521 1429 1330 1184
Medium High 1516 1493 1482 1464 1442 1411 1343 1275 1192 1035
Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851
Low 1126 1115 1095 1049 1027 996 957 929 840 742
LM(8,L)M100C16MP11
High 2009 1994 1933 1893 1836 1763 1691 1606 1508 1389
Medium High 1523 1506 1521 1490 1466 1435 1393 1326 1241 1119
Medium Low 1230 1249 1245 1230 1218 1195 1161 1120 1039 949
Low 1126 1115 1095 1049 1027 996 957 929 840 742
LM(8,L)M100C20MP11
High 2817 2774 2712 2620 2551 2465 2375 2266 2131 1992
Medium High 1958 1946 1924 1901 1850 1813 1752 1675 1598 1502
Medium Low 1539 1523 1519 1491 1449 1395 1351 1270 1197 1098
Low 1276 1218 1229 1178 1126 1084 1017 958 890 819
LM(8,L)M120C20MP11
High 2828 2768 2699 2612 2524 2423 2308 2219 2118 1982
Medium High 2085 2073 2042 2029 1967 1896 1893 1816 1717 1635
Medium Low 1620 1631 1636 1593 1567 1557 1520 1476 1407 1263
Low 1322 1311 1302 1271 1241 1201 1162 1101 1042 979

This manual suits for next models

1

Other Luxaire Furnace manuals

Luxaire TM9T Quick start guide

Luxaire

Luxaire TM9T Quick start guide

Luxaire G8D08016UHB11 Quick start guide

Luxaire

Luxaire G8D08016UHB11 Quick start guide

Luxaire P*DU & G8D-UH series User manual

Luxaire

Luxaire P*DU & G8D-UH series User manual

Luxaire TG8S Quick start guide

Luxaire

Luxaire TG8S Quick start guide

Luxaire TM9X Quick start guide

Luxaire

Luxaire TM9X Quick start guide

Popular Furnace manuals by other brands

Goodman GKS9 installation instructions

Goodman

Goodman GKS9 installation instructions

Daikin DM92SE Service instructions

Daikin

Daikin DM92SE Service instructions

Alpine Home BG802DFE installation instructions

Alpine

Alpine Home BG802DFE installation instructions

Lennox Elite series installation instructions

Lennox

Lennox Elite series installation instructions

Empire Heating Systems DV-25-2SG Installation instructions and owner's manual

Empire Heating Systems

Empire Heating Systems DV-25-2SG Installation instructions and owner's manual

Dometic AFM Series Technical installation manual

Dometic

Dometic AFM Series Technical installation manual

Empire Comfort Systems DV-20E-1 Installation instructions and owner's manual

Empire Comfort Systems

Empire Comfort Systems DV-20E-1 Installation instructions and owner's manual

American Standard BAYLPSS410B Installer's guide

American Standard

American Standard BAYLPSS410B Installer's guide

Lennox GHR26 series User's information manual

Lennox

Lennox GHR26 series User's information manual

Carrier 58CU0A Series Installation, start-up, operating and service and maintenance instructions

Carrier

Carrier 58CU0A Series Installation, start-up, operating and service and maintenance instructions

Bryant Deluxe 340AAV Product data

Bryant

Bryant Deluxe 340AAV Product data

Payne PG8MVA installation instructions

Payne

Payne PG8MVA installation instructions

Trane L8V1A040U3VSBA Installation, operation and maintenance

Trane

Trane L8V1A040U3VSBA Installation, operation and maintenance

ICP N8MPN installation instructions

ICP

ICP N8MPN installation instructions

Amana 10759833 installation instructions

Amana

Amana 10759833 installation instructions

Carrier 58STX Product data

Carrier

Carrier 58STX Product data

Trane XR80 Other

Trane

Trane XR80 Other

Bryant 912SC Product data

Bryant

Bryant 912SC Product data

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.