CTK0* WIRING .................................................43
COMFORTNET SYSTEM ADVANCED FEATURES ....................44
FURNACE ADVANCED FEATURES MENUS .........................45
THERMOSTAT MENU ..........................................47
DIAGNOSTICS .................................................47
NETWORK TROUBLESHOOTING ..................................47
SYSTEM TROUBLESHOOTING ...................................48
FAULT RECALL SEQUENCE ....................................48
FAULT CLEAR SEQUENCE .....................................48
NORMAL SEQUENCE OF OPERATION ........................48
POWER UP..................................................48
HEATING MODE .............................................48
COOLING MODE .............................................49
FAN ONLY MODE ............................................49
OPERATIONAL CHECKS .......................................49
SAFETY CIRCUIT DESCRIPTION..............................49
INTEGRATED CONTROL MODULE ...............................50
PRIMARY LIMIT ...............................................50
AUXILIARY LIMIT .............................................50
ROLLOUT LIMIT .............................................50
PRESSURE SWITCHES..........................................50
FLAME SENSOR ..............................................50
TROUBLESHOOTING ..........................................50
ELECTROSTATIC DISCHARGE (ESD)PRECAUTIONS .................50
DIAGNOSTIC CHART ...........................................50
RESETTING FROM LOCKOUT ...................................50
MAINTENANCE .................................................51
ANNUAL INSPECTION .........................................51
FILTERS .....................................................51
BURNERS ....................................................52
INDUCED DRAFT AND CIRCULATOR BLOWERS ....................52
CONDENSATE TRAP AND DRAIN SYSTEM
QUALIFIED SERVICER ONLY)................................52
FLAME SENSOR (QUALIFIED SERVICER ONLY) ...................52
FLUE PASSAGES (QUALIFIED SERVICER ONLY) ...................52
BEFORE LEAVING AN INSTALLATION ........................52
REPAIR AND REPLACEMENT PARTS..........................52
DIP SWITCHES.................................................53
STATUS CODES ................................................54
TROUBLESHOOTING CHART .................................55
WIRING DIAGRAM .............................................60
SPECIAL INSTRUCTIONS FOR PRODUCTS INSTALLED
IN THE STATE OF MASSACHUSETTS .................61
G
OODMAN
WILL
NOT
BE
RESPONSIBLE
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
ARISING
FROM
IMPROPER
SERVICE
OR
SERVICE
PROCEDURES
. I
F
YOU
INSTALL
OR
PERFORM
SERVICE
ON
THIS
UNIT
,
YOU
ASSUME
RESPONSIBILITY
FOR
ANY
PERSONAL
INJURY
OR
PROPERTY
DAMAGE
WHICH
MAY
RESULT
.
M
ANY
JURISDICTIONS
REQUIRE
A
LICENSE
TO
INSTALL
OR
SERVICE
HEATING
AND
AIR
CONDITIONING
EQUIPMENT
.
DRAIN EXITING LEFT SIDE ....................................20
UPFLOW MODEL INSTALLED HORIZONTALLY
WITH RIGHT SIDE DOWN...................................21
UPFLOW MODEL INSTALLED HORIZONTALLY WITH LEFT SIDE DOWN ..21
COUNTERFLOW MODEL INSTALLED VERTICALLY ..................22
DRAIN EXITING LEFT SIDE ....................................22
DRAIN EXITING RIGHT SIDE ...................................22
COUNTERFLOW MODEL INSTALLED HORIZONTALLY
WITH RIGHT SIDE DOWN...................................22
COUNTERFLOW MODEL INSTALLED HORIZONTALL
WITH LEFT SIDE DOWN....................................23
ELECTRICAL CONNECTIONS .................................23
WIRING HARNESS ............................................23
115 VOLT LINE CONNECTIONS ................................23
JUNCTION BOX RELOCATION ...................................24
24 VOLT THERMOSTAT WIRING ................................24
SINGLE-STAGE HEATING THERMOSTAT APPLICATION ...............25
24 VOLT DEHUMIDISTAT WIRING ...............................25
FOSSIL FUEL APPLICATIONS ....................................26
115 VOLT LINE CONNECTION OF ACCESSORIES
(HUMIDIFIER AND ELECTRONIC AIR CLEANER) ................26
AUXILIARY ALARM SWITCH: ...................................27
GAS SUPPLYAND PIPING......................................28
HIGH ALTITUDE DERATE ......................................28
PROPANE GAS CONVERSION ...................................28
GAS PIPING CONNECTIONS ....................................29
PROPANE GAS TANKS AND PIPING ..............................31
CIRCULATING AIR & FILTERS ................................32
DUCT WORK -AIR FLOW .....................................32
CHECKING DUCT STATIC ......................................32
BOTTOM RETURN AIR OPENING [UPFLOW MODELS] .............33
FILTERS - READ THIS SECTION BEFORE
INSTALLING THE RETURN AIR DUCT WORK ...................33
UPRIGHT INSTALLATIONS .......................................34
HORIZONTAL INSTALLATIONS ...................................35
STARTUP PROCEDURE & ADJUSTMENT .....................35
DRAIN TRAP PRIMING.........................................35
FURNACE OPERATION .........................................35
GAS SUPPLY PRESSURE MEASUREMENT .........................36
GAS MANIFOLD PRESSURE MEASUREMENT AND ADJUSTMENT ......38
GAS INPUT RATE MEASUREMENT (NATURAL GAS ONLY)..........38
TEMPERATURE RISE ..........................................39
CIRCULATOR BLOWER SPEEDS .................................39
BLOWER HEAT OFF DELAY TIMINGS ...........................42
COMFORTNET™ SYSTEM......................................42
OVERVIEW ..................................................42
AIRFLOW CONSIDERATIONS ....................................43
FOSSIL FUEL APPLICATIONS ....................................43