METHOD 1 METHOD 2
Assemble the mount before installing into
place (for single unit or small array).
Install piece by piece on a located wall (for
multiple or large video wall array).
CAUTION STATEMENTS
1. READ ALL STEPS WITHIN THIS MANUAL BEFORE INSTALLING THE MOUNT. SAMSUNG IFJ LED
SERIES INSTALLATION GUIDE MUST BE READ IN CONJUNCTION FOR SUCCESSFUL
INSTALLATION. ANY QUESTIONS? CALL PDS.
2. FRAME MUST BE PLUMBED, SQUARED, LEVELED, X, Y, AND Z ALIGNED PRIOR TO INSTALLATION OF
ANY DISPLAYS.
3. ALL LED CABINETS MUST BE POWER ON TESTED PRIOR TO ANY INSTALLATION.
4. PDS RECOMMENDS THE HANDLING LED CABINETS BY AN INDUSTRY QUALIFIED PROFESSIONAL.
5. PDS IS NOT RESPONSIBLE FOR DEFECTS, MISUSE, OR IMPROPER HANDLING OF THE LED CABINETS.
Tools for Installation:
00.0 o
Spool of
colored strings
Anti-Static
Gloves
FBWM SAM IFJ
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100 Page 3
Imperial
(Inches)
Metric
(Milimeters)
X
1 Wide 31.718 805.6
2 Wide 63.466 1612.1
3 Wide 95.214 2418.5
Y
1 High 17.828 452.8
2 High 35.686 906.4
3 High 53.545 1360.1
4 High 71.403 1813.6
5 High 89.261 2267.2
VIDEO WALL DIMENSIONS AND MOUNTING LOCATIONS
Determine the overall dimensions of the mount by
using the table within this page.
For example: 3X3 array would be 95.22” x 53.54” but
larger array i.e., 9X9 would consist of multiple rails for
an overall of 285.65” x 160.66”.
1" HANG
LOCATION
48" APART
HANG LOCATION
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
Page 4
PRE-INSTALLATION
Nylon Washer
Steel Washer
M5 x 10mm
Comb Screw
M6 x 35mm
Socket Screw
Default Position and aligment
notch for wall leveling bracket
Floating Adjustment
Assembly (or “Floaters”)
Even array - e.g. 6 Wide
Odd array - e.g. 3 Wide
Identifier for the
top or bottom
horizontal rail
UNUSED
FLOATER
LOCATION
1/2”-13 x 1.5”
Bolt With Hole
To keep flange
straight during
SHIPPING.
NOT required for
INSTALLATION.
Wall Leveling
Bracket
Floaters must be install on each corner of the entire array and every other location (indicated by the notch).
2nd 3rd1st every otherand
corner location
every other column
1. Identify the square cutout with a V-notch to determine
the placement and direction of the Floating Adjustment
assembly (or “ ”) shown on above.
2. Install on every other column and corner locations of the
mount.
3. Fasten using (2) M5 x 10mm Comb Screw, (2) Nylon
Washers, (2) Steel Washers.
4. Install 1/2”-13 x 1.5” Bolt with Hole onto each threaded
extrusion and a M6 x 35mm Socket Screw for ease of
installation in sequential step.
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
1
2
Page 5
Horizontal
Rail
M5 x 8mm
Flat Head
Install the Vertical and Horizontal Rails together using (4) M5x 8mm Flat Head Screw per.
1. Determine the desired location by calculating the height of the pre-mounting hang location using
the table on page 3.
2. Use any commercially available hardware to temporary hang the mount.
METHOD 1
Support
Screws
To temporary
hang the mount
48” apart
Vertical Rail
(center)
Vertical Rail
(left and right)
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
3
Page 6
1. Place a level on top of the mount and reinstall or adjust the support screws if necessary.
2.
using 1/4” x 5” Hex Lag and 1/4” Washer.
3. Maintain a 1/8” minimum gap from the anchor plate and the rail when anchoring.
4. Install the remaining mounting locations while keeping the mount leveled.
DIGITAL LEVEL
00.0 o
1/8” min. gap
Clearance
1/4” Washer
1/2”-13 x 1.5”
Bolt With Hole
Wall Anchor
Plate
Vertical Rail
1/4” x 5” Hex
Lag
Support Screw
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
1
Page 7
00.0 o
DIGITAL LEVEL
WALL WALL
1. Install (2) 1/2”-13 x 1.5” Bolt with Hole onto the threaded extrusion.
2.
3.
using 1/4” x 5” Hex Lag and 1/4” Washer.
4. Maintain a 1/8” minimum gap from the anchor plate and the rail when anchoring.
5. Level, Square, Plumb.
6. Install the remaining lag bolts, washers, and wall anchor plate.
METHOD 2
1/8” min. gap
Clearance
1/4” Washer
1/2”-13 x 1.5”
Bolt With Hole
Wall Anchor
Plate
Vertical Rail
1/4” x 5” Hex
Lag
Wall Anchor PlateWall Anchor Plate
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
2
3
Page 8
Vertical
Rail (Left)
Horizontal Rail
(Mounted)
1. Securely fasten each Vertical Rail to a mounted Horizontal Rail using (2) M5 x 8mm Flat
Head Screw per end.
2. Fasten the Lower Horizontal Rail but do not anchor until the mount is perfectly square. See
sequential step.
ASSEMBLE THE LOWER SECTION OF THE MOUNT
Install a few support screws (commercially available hardware) to temporary hold the lower
section in place prior to final mounting location.
Vertical Rail
(Right)*
M5 x 8mm
Flat Head
Lower
Horizontal Rail
*Single unit configuration shown above. Left and right rails are for the entire array.
Vertical Rail
(Center)
Installation is not finished within this step. After leveling the vertical brackets,
secure the bottom horizontal to the wall. See step 8 for additional detail.
Support
Screws
Do Not Anchor Prior to
Final Mounting Location
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
4
Page 9
0XOWLSOH8QLW&RQ¿JXUDWLRQ
1. Hang and position the second Horizontal Rail side by side.
2. Place a support screw while maintaining a leveled horizontal rail to temporary hold in place.
3. Install (2) Attachment Plate and fasten together using (4) M5 x 8mm Flat Head Screw for each rail.
4. Install the remaining Vertical Rails (center) using (4) M5 X 8mm Flat Head Screw.
5. Install the lower section of the mount as the steps above.
To extend the width of the unit, follow the steps below.
Extend Horizontally
Horizontal Rail
(1st unit)
Horizontal Rail
(2nd unit)
DIGITAL LEVEL
the seems between
two units 00.0 o
Attachment
Plate
M5 x 8mm Flat
Head Screw
Vertical Rail
(center)
Figure 1
Figure 2
Insert a support
screw temporary
hang the mount
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
5
Page 10
Extend Vertically
0XOWLSOH8QLW&RQ¿JXUDWLRQ
1. Position multiple units adjust to each other.
2. Joint the units together using multiple Attachment Plate and fasten using
(2) M5 x 8mm Flat Head Screw per.
3. When extending the height of a video wall array, the middle row shares the
Horizontal Rail between two units. Additional Horizontal is not required.
To extend the height of the unit, follow the steps below.
No additional
Horizontal Rail
No additional
Horizontal Rail
Required.
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
6
Page 11
Inspect each bracket using a Square and Level tool.
DIGITAL LEVEL
SQUARE AND LEVEL
00.0 o
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
7
Page 12
0.281” Dia hole
M5 x 0.5mm
tapped hole
(with supplied
M5 x 20mm)
1. Install whereever necessary.
2. Use multiple drywall or wood screws to bring the bracket closer to the wall.
3. Use multiple M5 x 0.5 tapped screws to bring the brackets away from the wall.
FINETUNE THE HORIZONTAL AND VERTICAL RAIL
Towards the wall
Against the wall
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
8
Page 13
VERY IMPORTANT: VERIFYING THE DIAGONAL MEASUREMENTS
REMINDER
1. Measure the distance from corner to corner
with a measuring tape.
2. Measure diagonally opposite and verify the
diagonal measurements.
3. Proceed only if the two measurements are
equivalent.
4. Secure the lower mounting location by sliding
a Wall Anchor Plate behind the mount
and fasten using 1/4” x 5” Hex Lag and 1/4”
Washer.
INSTALL THE LOWER
MOUNTING LOCATIONS
Distance 1
Distance 2
The two diagonal
measured distances
must match
1/8” min. gap
Clearance
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
9
Page 14
1. Tie a string from one end to the other end of the entire array.
2. Tie horizontally and crisscross, especially for large video wall array.
3. Inspect for any gaps between the brackets and the string.
4. Adjust any neccessary mounting location. See Figure 2.
FINAL ALIGMENT AND ADJUSTMENT
In / Out
Figure 2
Figure 3
Gaps between
multiple units
FBWM Mount
String (Z-axis indicator)
Figure 1
STRING
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
10
Page 15
Uneven wall surfaces can be
adjust by turning the Flush Bolt.
In / Out
Adjustments
REMINDER
1/8” min. gap
Clearance
Up / Down
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
11
12
Page 16
NOTES: If using the additional slots for mounting points, make sure that the floating frame is
fully level tothe wall vertically and horizontally. Must use shims (commercially available) on
every slots being used tofill the void between the wall and the frame. Avoid over tightening the
screws as this would make the floating frame uneven.
Insert multiple M5 x 0.5 x 10mm Cup Point Set Screws on the left, right, and bottom side of the
mount. Adjust the LED Cabinets in sequential steps.
Additional
Slots
FILL VOIDS
WITH SHIMS
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
13
Page 17
LED Cabinet
Single unit configuration, 3 Wide by 2 High Video Wall, shown for clarity.
87612345
Example: 8X4 Array
SAMSUNG IFJ LED DISPLAY INSTALLATION MANUAL must be read in conjunction with
Improper installation may cause damage to the LEDs.
Keyhole Slot
1. Install the first LED Cabinet from the center
bottom row of the mount.
2. Position the LED Cabinet into the keyhole slot
and slowly lower the cabinet.
3. Install adjacent or sequential cabinets and
expand outward.
4. Finetune the LED Cabinets. Adjust the set screws
located on the left, right, and bottom side of the mount.
A
N
T
I
-
S
T
A
T
I
C
G
L
O
V
E
S
FBWM SAM IFJ

Installation Guide
FBWM SAM IFJ
www.premiermounts.com | North America 800.368.9700 | International +1-714-632-7100
14
Page 18
1. Place a Gap-It Tool to wedge between two LED Cabinets to prevent
abrupt release of the cabinets.
2. Slowly slide the Gap-It tool away from the LED Cabinets while lowering
into place. See Figure 2.
RECOMMENDATION ONLY: INSTALL WITH GAP-IT TOOL
PDS IS NOT RESPONSIBLE FOR ANY IMPROPER HANDLING OF
THE LED CABINETS.
Figure 2
Cautionary Advice:
Do not damage the
LEDs when lowering.
Figure 1
SLOWLY
FBWM SAM IFJ

Premier Mounts intends to make this manual accurate and complete. However, Premier Mounts makes no claim that the information
contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with
the installation or use of this product. The information contained in this document is subject to change without notice or obligation of
any kind. Premier Mounts makes no representation of warranty, expressed or implied, regarding the information contained herein.
PREMIER MOUNTS
LIMITED WARRANTY
WARRANTY COVERAGE:
Premier Mount’s\PDS warranty period for products used in “build-to-order” applications is 1 year for fabricated products.
Electronic actuators and controllers are covered for 3 years. Batteries are covered for 12 months. The Warranty period is
effective from the production date, as stated on the “ship date” and\or product label.
INITIATION OF A CLAIM:
Please contact Premier Mounts\PDS Inc. to obtain a Returned Materials Authorization (RMA) number prior to sending any
product back to Premier Mounts\PDS. The following information is required before issuing the RGA number:
• Premier Mounts\PDS Item number
• Statement describing defect
•
customer)
• Brief description of any failure or impact to surround equipment or surfaces.
HOW TO REQUEST AN RMA:
1. Submit your request via Email: Orders@PremierMounts.com
2. Premier Mounts\PDS shall have the option of inspection of the goods on Buyer's premises or authorizing their
return. No goods are to be returned without written consent nor shall Premier Mounts be liable for any expense,
including inspection expenses, incurred by Buyer in order to remedy defects in said goods.
3. Premier Mounts\PDS will, at their option, provide credit, repair, or replace such products determined by Premier
Mounts to be defective.
RETURNING THE PRODUCT TO PREMIER MOUNTS\PDS:
1. Products must be packed securely to insure no further damage upon arrival at Premier Mounts\PDS. Improperly
packaged items will be considered non-warranty.
2. Line rejects must be shipped to Premier Mounts\PDS in a separate box using a separate RMA number from any
3. Please return any defective products or parts to Premier Mounts\PDS. We will provide preferred carrier informa-
tion) or by UPS small parcel. Shipping charges for product that is covered by warranty will be covered by Premier
Mounts\PDS. Product that is non warrantable will be returned to the customer at their expense.
WARRANTY UNITS - FIELD REJECTS:
a. Field Rejects will be analyzed and full credit, repair, or replacement at Premier Mounts\PDS decision. If the prod-
ucts returned to Premier Mounts\PDS must be returned to the customer, the products will be repaired and marked
as refurbished.
b. For metal frames and structures that are integrated into the architecture, Premier Mounts will coordinate inspec-
tion to determine corrective action. Field repairs may be made at Premier Mounts direction and warranty units
c. For product that is returned and is found to have a non-warranty failure, the product will be scrapped and no
credit will be issued.
d. If the evaluation is complete and there is a “No Fault” found, a re-manufactured label will be placed on each unit
and the units will be returned to the customer. The customer will be responsible for return shipment costs.
REPAIR OF NON-WARRANTY PRODUCT:
a. If repair is needed for an item with a non-warranty failure, repair charges will be quoted via email. We request an
approval within 5 business days. If no response is received, the product will be scrapped.
b. The products will then be repaired and marked as refurbished. A re-manufactured label will be placed on each
unit.
c. Units outside the warranty period that are returned for evaluation will be charged an analysis fee of $40.00 per
unit.
d. Units outside the warranty period will not be repaired.
PREMIER MOUNTS
ATTN: Warrenty Claims
500 W Central Ave, Suite A
Brea, CA 92821
FBWM SAM IFJ
Table of contents