4| Regency PTO28-1 City Table Outdoor Gas Fireplace
|
4safety decal
This is a copy of the label that accompanies each PTO28 City Table Outdoor decorative gas appliance. We have printed a copy of the contents here for your
review.
NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
Part #: 919-327
Printer: Continue with Serial # series DO NOT start at 0
(previous 919-211)
Colour: Black on grey except what is indicated as being printed red.
Size: (File at 100%)12.525”x 2.7”
Material: 2 ml silver matt polyester (DPM SMS)
Dec. 11/13: Created draft for approval - Do not print
Jan. 15/14: Added ànd CGA 2.17 as per R/D
Feb.20/14: Updated Standard wording as per R/D
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
430
430
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, BC, Canada V4G 1H4
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
Listed: OUTDOOR DECORATIVE GAS APPLIANCE /
Certified for/Certifi e pour: CANADA and U.S.A.
Conforms to: ANSI Z21.97-2012
Certified to: CSA 2.41-2012 and CGA 2.17-M91(2009)
EXTÉRIEUR DÉCORATIFS APPAREIL À GAZ
é
.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
É É
é
QUIP A L'UISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: Mod le
PTO28CIT-LP1
PROPANE GAS: Model -LP1PTO28CIT
NATURAL GAS: Model PTO28CIT-NG1
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minimum input
Altitude
Maximum supply pressure Pression d'allimentation maximum
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement
Grandeur de l'injecteur
D bit Calorifique maximum selon
D bit Calorifique minimum selon
l'altitude
é é é
é basse
é
é
14” WC/C.E. (3.49 kPa)
5" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
0.5" WC/C.E. (0.12 kPa)
# 32 DMS
33,500 Btu/h (9.82 kW)
13,000 Btu/h (3.80 kW)
0-4500 ft/pi (0-1372 m)
Pression d'allimentation maximum
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement
Grandeur de l'injecteur
D bit Calorifique maximum selon
D bit Calorifique minimum selon
l'altitude
é é é
é basse
é
é
14" WC/C.E. (3.49 kPa)
12” WC/C.E. (2.99 kPa)
11” WC/C.E. (2.74 kPa)
1" WC/C.E. (0.25 kPa)
# 50 DMS
35,000 Btu/h (10.26 kW)
11,000 Btu/h (3.23 kW)
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minimum input
Altitude
Maximum supply pressure
Back Wall
A 12” (305mm)
Side Wall
B 12” (305mm)
Ceiling
C 45” (1143mm)
Unit Base
D 1” (25mm)
The installation must conform with local codes or, in the absence of local codes, with CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70. This appliance is only for use with the type of gas indicated on the rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux, avec CAN/CSA-B149.1, gaz naturel et du propane ou du Code d'installation au ANSI Z223.1/NFPA 54.
L'appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en l'absence de codes locaux, avec le Code canadien de l'électricité, CSA C22.1 ou avec le National Electrical Code, ANSI / NFPA 70.
Cet appareil est à utiliser uniquement avec le type de gaz indiqué sur la plaque signalétique. Voir le manuel du propriétaire pour les détails.
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le é PTO28CIT-NG1
FOR OUTDOOR USE ONLY /
POUR USAGE EXTÉRIEUR SEULEMENT
IF STORED INDOORS, DETACH AND LEAVE CYLINDER OUTDOORS / SI VOUS LE GARDER À L'INTÉRIEUR, DETACHER LE CYLINDRE ET LAISSER À L'EXTÉRIEUR 919-327
PTO28CIT-LP1
PTO28CIT-NG1
4001172 C
AB
D