7.
Changing the Downrod
(Optional)
Please see following steps on changing
the downrod prior to installation.
1. Remove hanger ball from 4” downrod by
loosening the set screw at the top of the
downrod which holds the hanger ball to the
downrod. (This is not the screw with the green
ground wire attached).
2. Slide the hanger ball down the downrod and
remove the support pin.
3. Insert the support pin in the holes at the top of
the 6” downrod and slide the hanger ball up
the 6” downrod. Make sure the support pin is
properly seated in the grooves in the top of the
hanger ball.
4. Tighten the set screw.
5. Return to page 5 to continue the installation.
WARNING
WHEN USING THE STANDARD BALL HANGER
PIPE MOUNTING, THE TAB IN THE RING AT THE
BOTTOM OF THE MOUNTING PLATE MUST REST
IN THE GROOVE OF THE HANGER BALL. FAILURE
TO PROPERLY SEAL THE TAB IN THE GROOVE
COULD CAUSE DAMAGE TO WIRING.
Installing Room Conditioner
to the Electrical Box
1. Pass the 120 Volt supply wires through the center
hole in the ceiling mounting plates shown in Figure
12.
2. Remove the mounting screws from the outlet
box,install the flat washers (supplied in the
hardware bag) to the mounting screws, then install
the ceiling mounting plate on the electrical box by
using 2 mounting screws with flat washers attached.
When using close to ceiling mounting, it is
important that the mounting plate be level. If
necessary use leveling washers (not included)
between the mounting plate and the electrical box.
Note that the flat side of the mounting plate is to be
toward the electrical box.
3. Securely tighten the 2 mounting screws.
4. Carefully lift the Room Conditioner assembly
up to the ceiling mounting plate. If using close to
ceiling mounting, hang the Room Conditioner on
the hook provided by utilizing one of the holes at
the outer rim of the ceiling canopy. If using standard
mounting, seat the hanger ball in the mounting plate
socket. Make sure the tab on the mounting socket
is properly seated in the groove in the hanging ball.
WARNING
THE HOOK AS SHOWN IN FIG. 13 IS ONLY
TO BALANCE ROOM CONDITIONER WHILE
ATTACHING WIRING. FAILURE TO HANG AS
SHOWN IN FIG. 13 MAY RESULT IN HOOK
BREAKING CAUSING THE ROOM
CONDITIONER TO FALL. HOOK MUST PASS
FROM INSIDE TO OUTSIDE OF CANOPY.
CAUTION
WHEN MOUNTING THE ROOM CONDITIONER ON
A SLOPED CEILING, THE STANDARD BALL
DOWNROD MOUNTING METHOD MUST BE
USED. THE MOUNTING PLATE MUST BE
MOUNTED SO THAT THE SLOT OPENINGS ARE
ON THE LOWER SIDE BY SLIDING THE
MOUNTING PLATE FROM THE TOP DOWN.