Snell & Wilcox SHDSDA2S-S1 Installation manual

SHDSDA2 OPERATION
System HD Dual Channel HD-SDI Distribution
Amplifier Operation Manual
SHDSDA2 Version 1 Issue 3 030402 1
CONTENTS
INTRODUCTION TO THIS OPERATION
MANUAL................................................................2
SCOPE OF THIS OPERATION MANUAL.............3
MODULE DESCRIPTION.................................3
FEATURES............................................................4
TECHNICAL PROFILE..........................................5
INPUT (CHANNELS 1 AND 2)..........................5
OUTPUTS (CHANNELS 1 AND 2)....................5
INDICATOR LEDS............................................5
Enhanced Monitoring Option........................5
ROLLCALL.....................................................5
OPTIONS..........................................................5
REAR INTERFACE CONNECTIONS....................7
REAR INTERFACE NOTATION GUIDE...........7
STANDARD INPUTS ........................................7
STANDARD OUTPUTS ....................................8
ROLLCALL MENU SYSTEM.................................9
ROLLCALL MONITORING FEATURES.............10

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 2
Introduction to this Operation Manual
This manual covers the operation and use of the modules described below.
WARNING…
THE FRONT PANEL OF THE UNIT MUST NOT BE
OPENED BY THE OPERATOR. ACCESS IS ONLY
PERMITTED TO FULLY QUALIFIED
INSTALLATION ENGINEERS.
System HD Modules must only be installed and/or replaced by qualified service personnel, with reference to
the System HD Installation guide. Refer all installation and servicing to qualified personnel only.
Manufacturers Notice
Copyright protection claimed includes all forms and matters of copyrightable material and information now
allowed by statutory or judicial law or hereinafter granted, including without limitation, material generated from
the software programs which are displayed on the screen such as icons, screen display looks etc.
Reproduction or disassembly of embedded computer programs or algorithms is prohibited.
No part of this publication may be transmitted or reproduced in any form or by any means, electronic or
mechanical, including photocopy, recording or any information storage and retrieval system, without permission
being granted, in writing, by the publishers or their authorised agents.
Important Notice
No responsibility is taken by the manufacturer or supplier for any non-compliance to EMC standards due to
incorrect installation.
Information in this manual and software are subject to change without notice and does not represent a
commitment on the part of Snell & Wilcox Ltd. The software described in this manual is furnished under a
licence agreement and may not be reproduced or copied in any manner without prior agreement with Snell &
Wilcox Ltd. or their authorised agents.

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 3
Scope of this Operation Manual
This is the operation manual for the System HD Distribution Amplifier module. It covers the modules ordered
under the following codes :
SHDSDA2S-S1 – Standard dual channel distribution amplifier with 4 outputs per channel
SHDSDA2E-S1 – Dual channel distribution amplifier with 4 outputs per channel and enhanced
reporting capabilities
SHDSDA2S and SHDSDA2E Dual Channel Distribution Amplifiers, Rear Panel View
Module Description
The Dual Channel HD-SDI Distribution Amplifier
provides up to four electrical HD-SDI outputs from
each of two independent HD-SDI bitstream inputs.
Each electrical high definition serial digital (HD-
SDI) bitstream is input into the distribution amplifier
main board via a 75ΩBNC connector on a rear
panel interface card. Each HD-SDI input signal is
then equalised and re-clocked before being split to
provide four electrical HD-SDI outputs via 75Ω
BNC connectors on the same interface card.
Two levels of monitoring sophistication are
available to the user. A standard operational level
is available on all boards, covering parameters
ranging from voltage supply status to the presence
of input signals. The optional enhanced monitoring
level provides a comprehensive analysis of the
incoming HD-SDI signals such as CRC error
detection, line standard and frame rate
identification.
Detailed performance information can be obtained
via the RollCall interface.
WARNING…
THE FRONT PANEL OF THE UNIT MUST NOT
BE OPENED BY THE OPERATOR. ACCESS IS
ONLY PERMITTED TO FULLY QUALIFIED
INSTALLATION ENGINEERS.
It is recommended you write the System HD Order
Code of the board this manual accompanied in the
table on the following page. This will allow easy
identification of the monitoring level of the main
board when referring to this manual at a later date.
Quick guide to order codes:
SHD SDA2 XS X
Dist. Amplifier
Code Properties
SStandard reporting
EEnhanced reporting
Interface card
option code Interface card supplied with
main amplifier board
210 BNC labelled for dual ch.
Codes other than those listed refer to custom
options.

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 4
Features
nDual channel capability
nFour equalised and reclocked data outputs from each input
nSMPTE292M 1.485Gbit/s HD-SDI data rate supported
nCan equalise over 100m of cable
nAlarm functions for poor quality input signals and device malfunction
nStand-alone or RollCall operation
nIncoming signal analysis available as an option, it includes:
CRC status
Line standard
Frame Rate
Error rate
Note:
RollCallTM enabled for remote system control & monitoring.

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 5
Technical Profile
INPUT (Channel 1 and 2)
Electrical 1.485GBit/s HD-SDI
Connector Format BNC 75ohm panel jack
Input Cable Length 100m
Peak-to-peak
signal amplitude 800mV ±10%
D.C. offset 0V ±0.5V
Rise time (20-80%)
Fall time (20-80%)
Difference
< 270ps
< 270ps
≤100ps
Return loss >15dB
OUTPUTS (Channel 1 and 2)
Electrical 1.485Gbit/s HD-SDI
Connector Format BNC 75ohm panel jack
Outputs 4
Peak-to-peak
signal amplitude 800mV ±10%
D.C. offset 0V ±0.5V
Rise time (20-80%)
Fall time (20-80%)
Difference
< 270ps
< 270ps
≤100ps
Return loss >15dB
INDICATOR LEDS
Not accessible to the Operator
Standard
Power Power supplies valid
Fault Board fault
Enhanced Monitoring Option
CPU Valid CPU activity
For both data channels
PLL Lock Output locked to input
standard
CRC Error Data error
Line Indicates line standard
Frame Indicates frame rate
Prog/Int Indicates progressive or
interlaced frames
RollCall™
‘Standard’ RollCall
monitoring options: General alarm
Supply voltage levels
Board temperature
‘Enhanced’ RollCall
monitoring options: For both data channels
CRC status
Line standard
Frame rate
Error rate
POWER CODE 1
WEIGHT <750gm (Main Board plus
Interface Board)
OPTIONS See page 2

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 6
Notes…
1. The dual channel HD-SDI distribution
amplifier (DA) is available with two levels of
monitoring sophistication. A standard
option which provides board level
information such as supply faults and
minimum incoming signal analysis. The
enhanced monitoring option adds a
comprehensive incoming signal analysis
capability, including the detection of CRC
errors and identification of the line
standard/frame rate of the signals being
distributed. Refer to the monitor option code
on page 2 to identify what monitoring level
is fitted to the DA board.
2. The interface card for the dual channel DA
contains ten BNC connectors of which all
ten are actually required for full operation
(two lots of one IN and four OUT). A single
channel eight output version of the DA card
is also available (order number SHD_SDA1-
SX) which provides eight outputs from a
signal input signal. A single channel DA
also has a 10 BNC rear interface card but
only nine BNC connectors are required
(one IN, eight OUT). The only difference
between the rear interface cards for the two
types of DA is in the backpanel labelling.
Mechanically these two different types of
rear interface card are completely
compatible with each other and can be
interchanged between the different types of
DA board. Refer to the interface card option
code on page 2 to identify what interface
card has been supplied with the dual
channel output DA main board.
CAUTION…
Confusion could arise if single/double channel
rear interface cards are assigned to the ‘wrong’
type of DA board. Though full functionality will
be maintained for both types of DA, the
difference in labelling could be misleading if all
such occurrences are not fully documented at
a system level.

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 7
Rear Interface Connections
Rear Interface Notation Guide
Electrical HD-SDI Input
A High Definition Serial Digital electrical input
though a 75ΩBNC connector is denoted in the
way shown opposite. The “ H ” denotes the High
Definition element and the “ n” is the connection
number for that particular rear interface.
Electrical HD-SDI Output
A High Definition Serial Digital electrical output
though a 75ΩBNC connector is denoted in the
way shown opposite. The “ H ” denotes the High
Definition element and the “ n” is the connection
number for that particular rear interface.
Standard Inputs (Channel 1 and
2)
Electrical HD-SDI
Used On : SHDSDA2S-S2
SHDSDA2E-S2
Each high definition serial digital electrical input is
connected to a 75ΩBNC connector. These
connectors are shown opposite and are labelled
H1 and H6 on the rear panel.

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 8
Standard Outputs (Channel 1 and
2)
Electrical HD-SDI
Used On : SHDSDA2S-S2
SHDSDA2E-S2
For each channel, the high definition serial digital
electrical output is available from four 75ΩBNC
connectors, each providing identical outputs. These
connectors are shown opposite and for a 2-channel
system are labelled H2, H3, H4 and H5 for channel
1 and H7, H8, H9 and H10 for channel 2

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 9
Rollcall Menu System
When a System HD Control and Monitor board is
fitted in the enclosure a range of monitoring
information is available to RollCall
External Monitoring Description
General alarm Input power fault or
overcurrent trip or
system failure
Supply voltage levels Actual voltage levels
Board temperature Actual board
temperature
With Enhanced Reporting Distribution
Amplifier
For both data channels
CRC Status
Line Standard
Frame Rate
Bit error rate Error rate over defined
time period

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 10
Rollcall Monitoring Features
nModule Infrastructure:
General Alarm
Supply Voltage Levels
Board Temperature
nIncoming Signal analysis:
Input Status.
Line Standard
Frame Type
Frame Rate
nCRC Error analysis:
CRC Error Count
CRC Error Total
CRC Reset
nBias/EQ – The value in this field is a guide to
the strength of equalisation that is being
applied to the input signal for longer cable
runs. The lower the value, the less equalisation
is being employed. It is intended as a guide for
troubleshooting the system. It should be noted
that when an equalisation of 100% is shown, it
doesn’t necessarily mean that the maximum
input cable length has been reached. As soon
as CRC errors are being reported then the
input cable length should be decreased until an
error free signal can be received.

SHDSDA2 OPERATION
SHDSDA2 Version 1 Issue 3 030402 11
Manual Revision Record
Date Version No. Issue No. Change Comments
16/06/01 1 1 First draft document Issued
051001 1 2 Edited current feature list Only
states features that are present in
current release A1.0.000
New issue released
030402 1 3 New monitoring features added New issue released