Super Vac P244S User manual

P/N 008-15094
VENTILATOR USER GUIDE MODEL P244S

USER GUIDE
This manual covers the description, cautions, operation and maintenance of Super Vac Electric Ventilators
PS Series
Please take the time to read this manual before operating the ventilator.
Save this guide for future reference.
CONTENTS
1. BREAKAGE OR DAMAGE DURING SHIPMENT................................................................................................................................................................................2
2. GENERAL DESCRIPTION AND SPECIFICATIONS............................................................................................................................................................................3
3. PRODUCT SAFETY PRECAUTIONS......................................................................................................................................................................................................4
4. BEFORE OPERATING VENTILATOR................................................................................................................................................................................................... 4
5. OPERATION................................................................................................................................................................................................................................................ 5
6. MAINTENANCE AND REPAIR................................................................................................................................................................................................................5
7. TROUBLESHOOTING MOTOR OVERHEATING PROBLEMS........................................................................................................................................................ 6
8. EXTENSION CORDS..................................................................................................................................................................................................................................7
9. EXTENSION DUCTS .................................................................................................................................................................................................................................. 7
10. WARRANTY ..............................................................................................................................................................................................................................................8
11. CONTACT INFORMATION....................................................................................................................................................................................................................9
12. PARTS LIST.............................................................................................................................................................................................................................................10
13. EXPLODED VIEW.................................................................................................................................................................................................................................. 11

User Guide
2
1. Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it
correctly. Please read these instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a
description on the freight or express bill describing the damage and the number of pieces. Then write us and we will send you the
original bill of lading. Get a claim blank from the express or truck company. Fill the claim form out. Attach the claim blank to the
original bill of lading together with a copy of our invoice. Attach a memo on which you show the value of the damaged goods.
Mail or hand these papers to your local transportation agent. They will process your claim with reasonable promptness.
Please note, we cannot and will not enter claims for damages. If we filed claim here, it would be sent to your local freight agent
for verification and investigation. This time can be saved by your filing the claim directly. Every consignee is on the ground floor
and in contact with the local agent who inspects the damaged goods, and thus, each claim can be given individual attention.
Since our goods are packed to comply with the regulations of all railroad, truck, and express companies, we cannot allow
deduction from any invoice because of any damage, however, be sure to file your claim promptly. Our goods are sold F.O.B.
factory. We take receipt from the transportation company certifying that the goods were delivered to them in good order, and our
responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and in no case will the customer be out any expense if
they follow the above instructions.
Be sure to keep all damaged goods subject to examination of the truck or express company inspector, who may call on you some
time later. These damaged goods, of course, will belong to them, and they will inform you what to do with them. If you dispose
of these damaged goods, your claim may not be paid.

ELECTRIC VENTILATOR
3
P244S_VentilatorUserGuide-PS-Series.doc
REV
08/13/03
2. General Description and Specifications
Super Vac ventilators are specifically designed to provide a convenient and portable source of fresh air. Refer to decal affixed to
ventilator to determine proper operating voltage requirements. Super Vac electric ventilators are single speed, fresh air ventilators,
for use in extreme conditions.
Specifications1
1Specifications are subject to change without notification. Refer to model decal affixed to ventilator to determine
actual specifications.
2 TEAO = Totally enclosed air over motor
This ventilator is designed for high powered air movement. Super Vac’s patented propeller produces a greater intake of air and
eliminates turbulence at the tips. The high velocity screw action sweeps air back over the motor, enabling it to run cooler. The
patented 4-Blade propeller is cast from aluminum alloy. Each blade is statically balanced for high efficiency and long life.
All Super Vac ventilators are designed to accept optional spiral duct and adapters. Placing adapter and ducts on the output side
provides positive pressure ventilation. Place adapter and duct on the input side for negative pressure ventilation.
The square housing design gives the unit added strength and stability. Handles on each corner makes the ventilator easy to hang on
windows, doorways or ladders. Multiple units may be stacked using optionally available accessories.

User Guide
4
3. Product Safety Precautions
ØDo not use the ventilator for purposes other than its’ intended use.
ØDo not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
ØDo not wear loose clothing that could become entangled in the operating ventilator.
ØDo not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact factory
for replacements.
ØDo not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator,
immediately disconnect power source. Be certain all mechanical motion has stopped before removing foreign object.
ØDo not use with any power voltage other than the indicated voltage.
ØDo not place or operate ventilator on unsteady tables, slanted surfaces or other unstable surfaces.
ØNever handle energized power cords with wet hands.
ØNever let extension cords or plug connection lay in water. Locate the ventilator so that it cannot fall into water
inadvertently.
ØNever use this ventilator in any explosive environment.
4. Before Operating Ventilator
§Always operate this ventilator from a proper AC power source supplied through a ground fault interrupter receptacle. Test
receptacle for ground fault before plugging in the ventilator power cord.
§A complete inspection of the ventilator should be made prior to operation.
§Never use power cords with frayed, cut, or brittle insulation.
§Inspect power cord plug for sound connections to the ground fault interrupter circuit.
§Check all threaded fasteners for proper tightness.
§Inspect inlet and outlet guards for damage or missing pieces. Replace damaged or missing guards before operating
ventilator.
Table of contents