Recommended mounting procedures (cntd)
3. Select a desired position to mount the towel rail i.e. at least 600mm above the floor and 300mm away from all
permanent objects in the surrounding area.
4. Using a pencil, draw around the end of each tube to mark their positions on the wall ensuring that the rail is square
on the wall.
5. Screw the mounting inserts securely to the wall at the locations marked.
6. Press the towel rail onto the mounting inserts gradually, checking that each leg is lined up with the
mounting inserts before applying force.
7. Mount the towel rail with a single grub screw on each of the 4 brackets as shown in the drawing.
Safety information
As with any electrical appliance, you should be aware of basic safety precautions when using this heated towel rail.
Please read these instructions, and file them for future reference:
•Because this appliance gets hot, young children and infirm people should be closely supervised when nearby. Do not
let young children treat the towel rail as a toy.
•Special purpose tools are required for the replacement of the power supply cord and element.
•Be aware that the towel rail will get slightly hotter than normal during warmer weather and when insulated by towels.
•The rail should NOT be used for anything other than its intended use.
•Do not put the towels or anything else which has been in contact with hazardous liquids on this towel rail.
•Use this appliance only on the voltage specified on the rating label.
•Electrical work to be performed by a registered electrician.
•Do NOT immerse the towel rail in any liquid.
•Make sure the supply cord never touches heated surfaces.
•Ensure that the towel rail is wiped down from time to time with a damp cloth and a stainless steel cleaner. Do not use
any abrasives or corrosive cleaners.
•If the electrical cord or connection is damaged DO NOT attempt to repair; please contact the supplier.
WARNING: DO NOT install towel rails in areas which may be subjected to saturation of water resulting in ingress of
moisture. It is recommended that all units are protected via a R.C.D(Residual Current Device) circuit.
Operation:
It will take about ¾ hour to heat up to the desired temperature and can, if desired, be left running constantly.
Specifications
Code HTR 680 x 450 - ROUND HTR 800 x 600 - ROUND HTR 800 x 600C –ROUND CURVED
Height 680mm 800mm 800mm
Width 450mm 600mm 600mm
Depth 120mm 120mm 120mm
Bars 6 7 7
Electrical
Wattage 55W 100W 100W
Supply 230-240V ~ 50Hz, single phase
Class 1 –requires earth connection.