Accademia Laboratory Niko 1300M User manual

USER MANUAL
NIKO1300M MONO AMPLIFIER
!
1


www.accademialab.com
of 3 15
Rel: 1/8/2018 V1 RevA
AccademiaLab Srl
Manual release: 1/8/2018
Accademia Laboratory - Italy
Version: 1 rev A
Language: English
www.accademialab.com

1. Read these instructions. !
2. Keep these instructions. "
3. Heed all warnings. "
4. Follow all instructions. "
5. Do not use this apparatus near water. "
6. Clean only with a dry cloth. "
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions. "
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat. "
9. Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other. A
grounding-type plug has two blades and a third grounding prong. The
wide blade or"
the third prong is provided for your safety. If the provided plug does
not t into your outlet, consult an electrician for replacement of the
obsolete outlet. "
10. Protect the power cord from being walked on or pinched, particularly
at plugs, convenience receptacles, and the point where they exit from
the apparatus. "
11. Only use attachments/accessories specifed by the manufacturer. "
12. Use only with a cart, stand, tripod, bracket, or table specifed by the
manufacturer, or sold with the apparatus. When a"
cart is used, use caution when moving the cart/apparatus combination
to avoid injury from tip-over. "
13. Unplug this apparatus during lightning storms or when unused for
long periods of time. "
14. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has been exposed to
rain or moisture, does not operate normally, or has been dropped. "
!
15. Use the mains plug to disconnect the apparatus from the mains. "
16. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. "
17. DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPASHING
AND ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS
VASES, ARE PLACED ON THE EQUIPMENT. "
18. THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN
READILY OPERABLE.!
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM
COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL. !
TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC
MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE
AC RECEPTACLE. THE MAINS PLUG OF THE POWER SUPPLY CORD
SHALL REMAIN READILY OPERABLE. !
WATCH FOR THESE SYMBOLS:
The lightning bolt triangle is used to alert the user to the risk of electric
shock. !
The exclamation point triangle is used to alert the user to important
operating or maintenance instructions. !
MAGNETIC FIELD
CAUTION! Do not locate sensitive high-gain equipment such as pre-
amplifiers directly above or below the unit. Because this amplifier has a
high power density, it has a strong magnetic eld which can induce hum
into unshielded devices that are located nearby. The eld is strongest just
above and below the unit.#
www.accademialab.com
of 4 15
Rel: 1/8/2018 V1 RevA
SAFETY PRECAUTION

#
www.accademialab.com
of 5 15
Rel: 1/8/2018 V1 RevA
CONTENT INDEX
SAFETY INFORMATION
4
INTRODUCTION
6
INSPECTION
6
CONTENT
6
DESCRIPTION
7
CONTROL AND INDICATORS
8
MAIN POWER SWITCH
8
MAIN POWER BUTTON
8
INPUT SELECTOR SWITCH
8
INPUT GAIN SELECTOR
8
LED LOGO
9
LED STATUS INDICATOR
9
CONNECTIONS
10
POWER PANEL
10
POWER PLUG
10
MAIN POWER SWITCH
10
USB
10
TRIGGER JACK
10
INPUT PANEL
11
UNBALANCED RCA
11
BALANCED XLR
11
INPUT SELECTOR SWITCH
11
INPUT GAIN SELECTOR
11
OUTPUT PANEL
12
SPEAKON
12
BINDING POST
12
LOUDSPEAKER WIRING
13
SPEAKON NEUTRIK NL4
13
BINDING POST
13
TECHNICAL SPECIFICATION
14

This manual describe the functions of the Accademia
Niko1300M amplifier.
Initial inspection
Before starting up the following inspection should be
carried out.!
•Please carry out a visual inspection of the
packaging and the amplifier unit for possible
damage during shipment.!
•Please verify the shipment for completeness refer
to the table below.!
If there is any sign of damage or incompleteness to the
items listed in the table below please contact your local
dealer.!
www.accademialab.com
of 6 15
Rel: 1/8/2018 V1 RevA
INTRODUCTION
QUANTITY
CODE
DESCRIPTION
1
niko1300m
Niko1300M amplifier
1
A-32ST
Power cord
1
cov13a
protective coating
1
mirco60a
microfibre cloth
1
glove-wb
pair of pure cotton glove

System
Niko1300 is a truly “over-designed” amplifier
performing in any musical and sonic conditions with an
unprecedent dynamic. A unique high-end power
amplifier capable to drive the most demanding and
challenging loudspeakers on the market keeping a
superb sonic performance. !
Power amplifier
Niko1300M is a dual monobloc class A/B power
amplifier with 1300Wrms at 8Ohm and 1950Wrms at
4Ohm. With a 10Hz – 90KHz band-pass @ -3db
across all power levels.!
Power supply
Niko1300M have a dedicated analog power supplies
use two separate custom design 1000VA toroidal
transformers.Two capacitor filtering banks provide a
massive 100.000µF running at 85V with the capability
to store up to 300joule of energy to support even the
most demanding dynamic situation with even the
hardest loudspeakers like a band or orchestra is
performing right in front on you.Even for the power
supplies stage the electrical connections are made by
gold plated 4mm solid copper busbars to insure a
perfect and long-life electrical connections. !
Accordingly Niko1300M can manage an input voltage
between 110-260V with 50-60hz.#
www.accademialab.com
of 7 15
Rel: 1/8/2018 V1 RevA
NIKO1300M AMPLIFIER

!
Main Power switch
The circuit bracker [fig 1.1] of the Niko1300M is
located in the power panel section of the rear
panel.This special circuit breaker is a fuse-less bracket
that operate only with the magnetic principle.!
•OFF: the Niko1300M is isolated from that mains
power. Never turn off the circuit breaker before
wait 10 second from the standby
•ON: the Niko1300M check the system before
entering the standby mode. (2 second)
Main power button
The power button [fig 1.2] is located in the center of
the front panel.!
•STANBY (status led blue) : the Niko1300M is not
isolated from that mains power. the amplification
stages is power off. Only in this phase is safe to
operate with the input and output connection.
•ON (status led green) : the Niko1300M now is
completely turned on. the amplification stages are
fully power on. The system check before unmute
the output last 6 second.
Input selector switch
The input selector [fig 1.3] switch is located in the
center of the rear panel. It switch between balance
(XLR) and unbalance (RCA) input. !
Input gain selector
The gain selector [fig 1.4] is located under the input
selector switch. The gain selector is a input attenuator.!
www.accademialab.com
of 8 15
Rel: 1/8/2018 V1 RevA
CONTROL AND INDICATOR
fig 1.1
fig 1.4
fig 1.3
fig 1.2

Led Logo
The logo [fig 2.1A] led is located in the front panel, the
Accademia logo led turn it on when the amplifier is
ready.!
Status indicator
The status indicator led [fig 2.1B] is located just above
the main power button in the front panel. the colors of
the led detect 4 different state.!
led status
If the amplifier is in protection mode!
just turn it completely off and reboot the system.
LED COLOR
CODIFICATION
BLUE
The amplifier is in standby
GREEN
The amplifier is ready
YELLOW
The amplifier is in overtemperature allarm
RED (flashing)
The amplifier is in Protection Mode
www.accademialab.com
of 9 15
Rel: 1/8/2018 V1 RevA
CONTROL AND INDICATOR
fig 2.1
A
B

Power panel
Powercon 32A
In the rear panel is fitted a Neutrik (R) Powercon 32A
[fig 3.1D] whom provide the main power to the
amplifier.!
!
Only connect the Niko1300M to mains
power supplies with a ground conductor.
Circuit braker
The circuit fracker [fig 3.1C] of the Niko1300M is
located in the power panel section of the rear
panel.This special circuit breaker is a fuse-less bracket
that operate only with the magnetic principle.!
•OFF: the Niko1300M is isolated from that mains
power. Never turn off the circuit breaker before
wait 10 second from the standby
•ON: the Niko1300M check the system before
entering the standby mode. (2 second)
Usb update
This UPDATE USB port [fig 3.1A] is only for update
and technical interventions by authorized people only.!
Trigger
This minijack I/O [fig 3.1B] connection is designed for
future scope.#
www.accademialab.com
of 10 15
Rel: 1/8/2018 V1 RevA
CONNECTIONS
POWER PANEL
NO USER-SERVICEABLE PARTS INSIDE REFER
SERVICING TO QUALIFIED PERSONNEL.
TO PREVENT THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER OR BACK.
RISK OF ELECTRIC SHOCK
TRIG CIRCUIT BREAKER
INLET
CAUTION
UPDATE
2
1
3
4
5
6 0
GAIN
XLR connection
1-GND
2-Hot +
3-Cold -
XLR connection
1-GND
2-Hot +
3-Cold -
XLR
RCA
TWO BLOCKS ONE CHASSIS
AMPLIFIE
R
technology
DESIGNED ENGINEERED AND
HANDCRAFTED IN ITALY WITH
COMPONENTS OF REFERENCE
INPUTS PANEL
XLR BAL IN
RCA UNBAL IN
NEGATIVE
GND
POSITIVE SPEAKON
R
NO
MONOPHONIC
AMPLIFIER
I
ACCADEMIA
LABORATORY
HANDCRAFTED
IN
ITALY
fig 3.1
B
A
C
D

Input panel
The Niko1300M have two type of input switchable
through the input selector switch.!
Unbalance Input (RCA)
A 2 pin RCA [fig 4.1A] connector is provided for
unbalanced input use. The unbalanced input have
25Kohm inlet’s impedance.!
Balance Input (XLR)
A 3 pin female XLR [fig 4.1D] connector is provided for
balanced input use. The balanced input has 50Kohm
impedance. Pin 1 GND, Pin 2 Hot +, Pin 3 Cold -.!
Input selector switch
The input selector switch [fig 4.1B] is located in the
center of the rear panel. It switch between balance
(XLR) and unbalance (RCA) input.!
Input gain selector
The gain selector [fig 4.1C] is located under the input
selector switch. The gain selector is an input
attenuator. View [fig 4.2] for details.!
www.accademialab.com
of 11 15
Rel: 1/8/2018 V1 RevA
CONNECTIONS
GAIN
ATTENUATION
0
0db
1
-3db
2
-6db
3
-12db
4
-18db
5
-infdb
6
not used
POWER PANEL
NO USER-SERVICEABLE PARTS INSIDE REFER
SERVICING TO QUALIFIED PERSONNEL.
TO PREVENT THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER OR BACK.
RISK OF ELECTRIC SHOCK
TRIG CIRCUIT BREAKER
INLET
CAUTION
UPDATE
2
1
3
4
5
6 0
GAIN
XLR connection
1-GND
2-Hot +
3-Cold -
XLR connection
1-GND
2-Hot +
3-Cold -
XLR
RCA
TWO BLOCKS ONE CHASSIS
AMPLIFIE
R
technology
DESIGNED ENGINEERED AND
HANDCRAFTED IN ITALY WITH
COMPONENTS OF REFERENCE
INPUTS PANEL
XLR BAL IN
RCA UNBAL IN
NEGATIVE
GND
POSITIVE SPEAKON
R
NO
MONOPHONIC
AMPLIFIER
I
ACCADEMIA
LABORATORY
HANDCRAFTED
IN
ITALY
fig 4.1
B
C
A
D
fig 4.2

!
Output panel
Speakon
The NIKO1300M have a standard Neutrik (R) NL4
Speakon [fig 5.1D] connection in the rear panel.!
Binding post
A binding post [fig 5.1A, 5.1C] is fitted in the rear panel
connected in parallel with the NL4 in order to give the
possibility to connect every kind of loudspeakers. To
guarantee the widest compatibility with the costumer
products the NIKO1300M possess a GND [fig 5.1B]
connection in order to eventually connect the ground of
the shielded loudspeaker power cables.!
www.accademialab.com
of 12 15
Rel: 1/8/2018 V1 RevA
CONNECTIONS
POWER PANEL
NO USER-SERVICEABLE PARTS INSIDE REFER
SERVICING TO QUALIFIED PERSONNEL.
TO PREVENT THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER OR BACK.
RISK OF ELECTRIC SHOCK
TRIG CIRCUIT BREAKER
INLET
CAUTION
UPDATE
2
1
3
4
5
6 0
GAIN
XLR connection
1-GND
2-Hot +
3-Cold -
XLR connection
1-GND
2-Hot +
3-Cold -
XLR
RCA
TWO BLOCKS ONE CHASSIS
AMPLIFIE
R
technology
DESIGNED ENGINEERED AND
HANDCRAFTED IN ITALY WITH
COMPONENTS OF REFERENCE
INPUTS PANEL
XLR BAL IN
RCA UNBAL IN
NEGATIVE
GND
POSITIVE SPEAKON
R
NO
MONOPHONIC
AMPLIFIER
I
ACCADEMIA
LABORATORY
HANDCRAFTED
IN
ITALY
fig 5.1
B
C
A
D

Loudspeaker wiring
Neutrik NL4
Binding Post
PIN
CONNECTION
1+
POSITIVE
1-
NEGATIVE
2+
NOT CONNECTED
2-
NOT CONNECTED
PIN
CONNECTION
+ RED
POSITIVE
- BLACK
NEGATIVE
GREEN
GROUND
www.accademialab.com
of 13 15
Rel: 1/8/2018 V1 RevA
CONNECTIONS

www.accademialab.com
of 14 15
Rel: 1/8/2018 V1 RevA
TECHNICAL SPECIFICATION
Power at 1Khz (4Ohm min)
1300W @ 8Ohm
1950W @ 4Ohm
Frequency Response
10HZ-90KHz @ -3db
Input impedance
XLR 50kOhm
RCA 25KOhm
Operating temperature
0°C to 40°C at 90% relative humidity (non-
condensing)
AC Line Voltage and Frequency
100-130V @ 50Hz
220-260V @ 60Hz
Dimension
482x270x572mm (w, h, d)
650x583x850mm (w, h, d) packaging
Weight
70Kg Net
95Kg with packaging
POWER PANEL
NO USER-SERVICEABLE PARTS INSIDE REFER
SERVICING TO QUALIFIED PERSONNEL.
TO PREVENT THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER OR BACK.
RISK OF ELECTRIC SHOCK
TRIG CIRCUIT BREAKER
INLET
CAUTION
UPDATE
2
1
3
4
5
6 0
GAIN
XLR connection
1-GND
2-Hot +
3-Cold -
XLR connection
1-GND
2-Hot +
3-Cold -
XLR
RCA
ACCADEMIA LABORATORY
HANDCRAFTED IN ITALY
R
N O
STEROPHONIC AMPLIFIER
RCA UNBAL INXLR BAL IN
CH RIGHT
TWO BLOCKS ONE CHASSIS
AMPLIFIE
R
DESIGNED ENGINEERED AND
HANDCRAFTED IN ITALY WITH
COMPONENTS OF REFERENCE
INPUTS PANEL
CH LEFT
RCA UNBAL INXLR BAL IN
technology
NEGATIVECH RIGHT POSITIVE POSITIVECH LEFT NEGATIVE
GND SPEAKON SPEAKON
I
POWER PANEL
NO USER-SERVICEABLE PARTS INSIDE REFER
SERVICING TO QUALIFIED PERSONNEL.
TO PREVENT THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER OR BACK.
RISK OF ELECTRIC SHOCK
TRIG CIRCUIT BREAKER
INLET
CAUTION
UPDATE
2
1
3
4
5
6 0
GAIN
XLR connection
1-GND
2-Hot +
3-Cold -
XLR connection
1-GND
2-Hot +
3-Cold -
XLR
RCA
TWO BLOCKS ONE CHASSIS
AMPLIFIE
R
technology
DESIGNED ENGINEERED AND
HANDCRAFTED IN ITALY WITH
COMPONENTS OF REFERENCE
INPUTS PANEL
XLR BAL INRCA UNBAL IN
NEGATIVE
GND POSITIVE SPEAKON
R
N O
MONOPHONIC AMPLIFIER
I
ACCADEMIA LABORATORY
HANDCRAFTED IN ITALY
R
Windows OLE Object Windows OLE Object
Windows OLE Object Windows OLE Object
Windows OLE Object
Windows OLE Object
Windows OLE Object

www.accademialab.com
of 15 15
Rel: 1/8/2018 V1 RevA
This manual suits for next models
1
Table of contents