Admiral Staging STVLADB30 Product information sheet

www.admiralstaging.com
TRUSS
TOPPER/
FLOOR
STAND
Original user manual
VERSION 01
December 2023
SKU: STVLADB30
Manufacturer:
Rolight Theatertechniek B.V.
Josink Kolkweg 10
7545 PR Enschede , The Netherlands
Phone (+31)53 432 06 44
www.rolight.nl
Distributed by ADMIRAL

LEGEND
1. INTRODUCTION
The ADMIRAL TRUSS TOPPER / FLOOR STAND can
be used to support loads when placed on the floor
or as a temporary hanging bracket. They are mostly
used in temporary set ups in the entertainment
industry but can be used for permanent set ups in
museums, event venues, theatres etc. as well.
In this manual ELL stands for Entertainment Load
Limit. Meaning the device has an inherent double
safety factor (8:1) and is therefore suitable to
suspend loads above persons.
The TRUSS TOPPER / FLOOR STAND is also designed
to meet the German regulation for loads above
persons DGUV17/18 (formerly known as BGVc1).
Clamps, couplers and safety cables used to
couple and secure the TRUSS TOPPER / FLOOR
STANDS to the supporting structure are not
included. The user must use certified clamps or
couplers with an ELL of at least 100 kg and with
minimum safety factor of 8:1 as required for
overhead liing.
ADMIRAL has endeavored to deliver the
highest degree of accuracy possible.
However continuous improvement of our products
is ADMIRAL policy. Therefore product specifications
are subject to change without notice.
Readers and users are encouraged to notify
ADMIRAL of errors and send in suggestions for
improvements. All communications will be carefully
considered for future printings of this manual and
changes to our products.
2. SAFETY INSTRUCTIONS
This user manual must be read and understood
prior to assembly, setup and servicing. All people
using and servicing the TRUSS TOPPER / FLOOR
STAND must familiarize themselves with the safety
instructions and user guidelines written in this
manual. This manual needs to be accessible for all
users at all times.
0. CONTENTS
DANGER
DANGER: Indicates a hazardous situation
which, if not avoided, will result in death
or serious injury.
This signal word is to be limited to
the most extreme situations.
WARNING
WARNING: Indicates a hazardous situation
which, if not avoided, could result in death
or serious injury.
CAUTION
CAUTION: Indicates a hazardous situation
which, if not avoided, could result in minor
or moderate injury.
NOTICE
NOTICE: Addresses practices not related to
personal injury.
0. CONTENTS
1. INTRODUCTION
2. SAFETY INSTRUCTIONS
3. SCOPE
4. LIMITATIONS OF USE
5. TECHNICAL DATA & LOADCHART
6. IDENTIFICATION
7. EXPLANATION OF THE STICKER
8. ASSEMBLY INSTRUCTIONS
9. DISASSEMBLY INSTRUCTIONS
10. STORAGE
11. MAINTENANCE & REJECTION CRITERIA
12. WARRANTY
13. EC DECLARATION OF CONFORMITY

SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS: Is used for lists
of steps, procedures or instructions that
might otherwise substitute a DANGER,
WARNING or CAUTION notification.
Note that equivalent phrases, such as SAFE
OPERATION PROCEDURES or SAFE SHUT
DOWN PROCEDURE, can be used in place of
the words “SAFETY INSTRUCTION”.
• The TRUSS TOPPER / FLOOR STAND can be
operated from -20° up to 60° Celsius.
• Do not exceed the maximum ELL
(entertainment load limit) stated on the product.
• Make sure the resulting forces on the supporting
structure are approved by a competent person
before applying the load.
• To determine the maximum suspended load
on the product, all imposed loads shall be
considered. e.g. the dynamic factor caused
by the liing machinery.
• Sound systems can be suspended but users
must check regularly the integrity of the
TRUSS TOPPER / FLOOR STAND as severe
vibrations could loosen bolts/knobs.
• The TRUSS TOPPER / FLOOR STAND must be
inspected by a competent person as oen as
required but with a minimum of 1 x per year.
Records of these inspections must be kept.
• Inspect equipment before every use.
A damaged TRUSS TOPPER / FLOOR STAND shall
be taken out of service.
• Outdoor use shall be approved by a
competent person and might influence the
load capacity. Do not expose the product
to full rain or snow. Outdoor use is the sole
responsibility of the operator.
• In case of use in the vicinity of saltwater,
the product shall be rinsed regularly with
fresh water to avoid corrosion.
WARNING
Check local legislation for the
application of use.
4. LIMITATIONS OF USE
WARNING
WARNING
Exceeding the limitations of use can
severely endanger the audience and users.
Dynamic factor of liing must be
considered separately.
3. SCOPE
The intended use of the TRUSS TOPPER / FLOOR
STAND is to support loads when placed on the
floor or as a temporary hanging bracket for loads of
maximum 100 kg.
Loads can be lighting fixtures, video projectors,
sound systems and/or equipment.
Any other way of use is considered to be a case of
misuse. Solely the user is liable for any damage or
injury resulting from such cases.
CAUTION
DO NOT li or load above people without
the following precautions:
• A TRUSS TOPPER / FLOOR STAND must
be taken out of service immediately if,
during use, repair or maintenance
damages are discovered.
• Remove people from the area during
installation.
• Use solely instructed and/or trained
personnel.
• Wear appropriate Personal Protective
Equipment (PPE) such as hard hats and
gloves during the installation.
• Make sure there is adequate amount
of working light during the installation
of the product.

F
F
F
F
F
F
• It is also imperative to observe the local
accident prevention regulations and/or
occupational health and safety regulations.
• The support structure, on which the
TRUSS TOPPER / FLOOR STAND is used, must
have lightning protection when used outdoors.
• The support structure, on which the TRUSS
TOPPER / FLOOR STAND is used, might need to
have electric potential bonding.
• Do not use the TRUSS TOPPER / FLOOR STAND to
guide currents for electric potential bonding.
• Make sure the TRUSS TOPPER / FLOOR STAND and
the supporting structure are dry and free of dirt.
When used as a TRUSS TOPPER / FLOOR STAND
make sure the surface is dry and free of dirt.
• Use appropriate packaging to transport the
products. e.g. a flightcase.
• Solely use by ADMIRAL approved parts to
replace damaged or lost parts.
• Do not re-zinc steel components as they
might be subject to hydrogene embrittlement.
WARNING
WARNING
Solely to be placed
on a flat surface
To be placed only in the
centre of the TRUSS TOPPER / FLOOR STAND
CAUTION
Do not throw the TRUSS TOPPER / FLOOR
STAND, as it might damage the product.
fig: 02
fig: 02
fig: 02
fig: 01
fig: 01
fig: 01
WARNING
WARNING
Make sure that if the TRUSS TOPPER /
FLOOR STAND is placed on a truss,
it should be secured with four M12 bolts
8.8 quality at all times.
Do not suspend the TRUSS TOPPER /
FLOOR STAND as shown below (fig 01).
It creates torsional forces and influences
the stability of the supporting structure.

5. TECHNICAL DATA & LOADCHART
ELL
100Kg
239 mm
290 mm
119.5 mm 119.5 mm
Technical data
Article code: STVLADB30
EAN: 8720094422824
ELL: 100 kg
Material: steel
Weight: 1,56 kg
Dimensions: 240 x 240 x 115 mm
Colour: Black powder coated
gloss 30% (RAL 9005)
Applicable Directives, Regulations,
Standards and Information Papers
The following directive is applicable
2006/42/EC Machinery directive
The following regulation is used
DGUV regulation17 Regulations for stages and
studios
(Formerly known as BGVc1)
Parts of the following standards and
information papers are used
DGUV Information Safety at productions and
events for television, radio,
film, theatre,
215-313 exhibitions: Loads above
persons
(Formerly known as BGI 810-3)
EN 17206:2020 Liing and load bearing
equipment for stages and
other production areas
within the entertainment
industry
BS 7905-1:2001 Liing equipment for
115 mm
90 mm
Ø 50 mm
Ø 12.5 mm
239 mm
290 mm

admiralstaging.com
DGUV
17 /18
ELL100
center point load
TRUSSTOPPER
FLOORSTAND
Article code: STVLADB30
Batchcode: ADB30-23-01
weight
1.56kg
8 720094 422824
admiralstaging.com
DGUV
17 /18
ELL100
center point load
TRUSS TOPPER
FLOOR STAND
Article code: STVLADB30
Batchcode: ADB30-23-01
weight
1.56kg
8 720094 422824
6. IDENTIFICATION
TRUSS TOPPER / FLOOR STAND
1Cams to stack them properly
2Pipe Ø 50 mm
3Notches to stack them properly
44 legs with rubber pads
2
1
3
6
4
5
7
8
9
10
7. EXPLANATION OF THE STICKER
TRUSS TOPPER / FLOOR STAND sticker
1Brand name
2Product name
3Article code
4Barcode
5EAN-code
6Batch code*
7CE Marking
8Weight
9Read the manual
10 Entertainment Load Limit
Bottom & top view
Side view
Front view
*Based on the Batch code ADMIRAL is
able to trace the date of manufacturing
2
2
1
1
4
4
3
3

7. EXPLANATION OF THE STICKER 8. ASSEMBLY INSTRUCTIONS
Note
Only place the TRUSS TOPPER / FLOOR STAND on
a level surface. Make sure it is virtually level before
mounting anything on it.
Step 1
Mount a fixture to the
TRUSS TOPPER / FLOOR STAND.
WARNING
Inspect the TRUSS TOPPER / FLOOR STAND
before use. Make sure all components are
in place and in good order. If damaged,
mark the item clearly and take out of
service*.
*See chapter 11 for further instructions!
Step 2
Make sure to line out the holes in the halfcones with
the holes in the truss. Tighten the bolts securely,
use a torque setting of 15Nm.
Step 1
Mount the halfcone onto the TRUSS TOPPER /
FLOOR STAND with M10 or M12 bolts. Use 8.8.
quality minimum. Using the maximal length possible.
Step 3
Place the TRUSS TOPPER / FLOOR STAND on top or
beneath the truss and secure the halfcone with the
conical truss pin.
Code:
Product:
Code:
Product:
WARNING
Check the integrity of the TRUSS TOPPER /
FLOOR STAND aer severe vibrations caused
by sound systems or if the supporting
structure was subject to severe movement
e.g. due to winds.
Standalone TRUSS TOPPER / FLOOR STAND
TRUSS TOPPER / FLOOR STAND on a truss
Standalone TRUSS TOPPER / FLOOR STAND

9. DISASSEMBLY INSTRUCTIONS
10. STORAGE
The TRUSS TOPPER / FLOOR STAND must be stored
in a dry, non-aggressive environment.
• Make sure the parts cannot bend.
• Avoid vibrations. Rubbing parts can cause
excessive wear and tear.
Step 2
Remove the TRUSS TOPPER / FLOOR STAND, loosen
the bolts and remove the halfcones from the TRUSS
TOPPER / FLOOR STAND.
Step 1
Remove the conical truss pin from the halfcone.
Code:
Product:
Code:
Product:
WARNING
If the TRUSS TOPPER / FLOOR STAND is
used to support loads above people it
might be needed to secure the load with
an additional safety cable. Make sure this
cable is attached with as less slack as
possible and has the correct load capacity.
In some countries the use of safety
cables is not required if the clamp and the
load attached to it can only be released by
use of tooling. In that case the bolt/nuts
must be fastened with a minimum torque
setting of 15Nm and the wingnut must be
removed in order to create the condition
to comply with this regulation (DGUV 215-
313).

WARNING
11. MAINTENANCE & REJECTION
CRITERIA
SAFETY INSTRUCTIONS
If damaged, mark the item clearly and take
it out of service.
The TRUSS TOPPER / FLOOR STAND hardly
needs any maintenance under normal use
and environmental circumstances.
For safety reasons however, all parts must
be checked regularly for dirt, damages,
loss and corrosion.
The TRUSS TOPPER / FLOOR STAND shall
be checked in compliance with the local
law by a competent person. Checking shall
take place as oen as required but with
a minimum of 1x per year. In case of doubt
contact ADMIRAL.
• Check all components for damages like
cracks, deformations, scratches and and
corrosion. Damaged and corroded parts shall
be rejected and thrown away.
• In general, scratches > 10% of the wall
thickness mean the product needs to be
rejected from use.
• In general, deformations > 10% of a straight
line from the outer surface mean the
product needs to be rejected from use.
• Remove all sharp and rough feeling edges
and surfaces by using sand paper or a file.
• Check welds for cracks, if welds are cracked
the product needs to be rejected from use.
CAUTION
When replacing parts, only use genuine
ADMIRAL components.

• For a period of 24 months we will repair, free
of charge, any damage attributable to faulty
materials or workmanship under the
condition that the equipment is forwarded,
freight paid, to our warehouse or one of the
ADMIRAL distributors’ warehouses.
• The warranty-period begins with the day of
the delivery, proven by a purchase receipt
like an invoice or delivery note or their
copies.
• The warranty does not cover damage due to
transport, negligent handling, overloading
the equipment or parts subject to normal
wear and tear signs. Nor damages that
originate from a case of misuse because of
nonobservance of the safety regulations in
this instruction manual.
• The warranty will be invalid when other
parts than the original ADMIRAL parts
have been used or modifications of our
design have been made by third parties.
• Warranty repairs do not renew nor extend
the warranty-period.
• In case of a claim that falls under the
warranty, e.g. a malfunction or spare part
requirements, please contact your point of
sale or ADMIRAL.
• The manufacturer is not liable for indirect
consequential damage and financial loss.
• The manufacturer shall not be liable for any
changes made to the TRUSS TOPPER / FLOOR
STAND parts nor for any damage resulting from
such changes.
12. WARRANTY

Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
info@rolight.nl
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
info@rolight.nl
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
info@rolight.nl
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
info@rolight.nl
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
13. EC DECLARATION OF CONFORMITY
Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
info@rolight.nl
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
EC-DECLARATION OF CONFORMITY FOR MACHINERY
(2006/42/EG Annex II)
Rolight Theatertechniek
Josink Kolkweg 10
7545 PR Enschede
The Netherlands
Herewith declares that:
ADMIRAL “TRUSS TOPPER / FLOOR STAND”; Article code STVLADB30
- Is in compliance with the Machinery Directive 2006/42/EEC annex II
- The following harmonized standards have been applied (or parts/clauses of): EN 12100-1-2010
- The following technical regulations , standards and information papers have been used
(parts/clauses of): German DGUV 17-18, German D DGUV 215-313,
EN 10204:2004, EN 17206 :2020, BS 7905-1 :2001
Enschede , The Netherlands 24-November-2023
Ms. E. Dijk
Owner Rolight Theatertechniek b.v.

Rolight theatertechniek bv
Josink Kolkweg 10
7545 PR Enschede
Vakmanschap in de entertainmentbranche
053 - 4 320 644
info@rolight.nl
www.rolight.nl
iban : NL38RABO 0127148426
bic : RABONL2U
k.v.k. : Enschede 06048772
btw : NL 8078.53.355 B01
Rolight
| www.admiralstaging.com | Josink Kolkweg 10 | 7545 PR Enschede |
| The Netherlands | Tel: +31 53 4 301 201 |
Table of contents
Other Admiral Staging Rack & Stand manuals