Advanced Amplifiers AA-1M6G-30 User manual

1 | P a g e - Ver. 1.0 –11-22
Instruction Manual Including Quick Start Guide
Advanced Amplifiers
Solid State RF Amplifier System
AA-1M6G-30
1 MHz - 6.0 GHz, 30 Watt, 45dB Min

2 | P a g e - Ver. 1.0 –11-22
Table of Contents
SAFETY INSTRUCTIONS ................................................................................................................................................................3
SPECIFICATIONS ...............................................................................................................................................................................4
ELECTRICAL SPECIFICATIONS: 50Ω, 25°C ....................................................................................................................4
ENVIRONMENTAL CHARACTERISTICS...........................................................................................................................4
MECHANICAL SPECIFICATIONS........................................................................................................................................4
OPERATING INSTRUCTIONS & GENERAL INFORMATION ...........................................................................................5
INTRODUCTION.......................................................................................................................................................................5
INCOMING INSPECTION ..................................................................................................................................................... 5
RF & AC CABLE CONNECTION ........................................................................................................................................5
RF TURN ON PROCEDURE ................................................................................................................................................. 5
RF TURN OFF PROCEDURE ................................................................................................................................................5
DECLARATION OF CE CONFORMITY.............................................................................................................................6
LIMITED WARRANTY .............................................................................................................................................................6
CONTACT INFORMATION ...................................................................................................................................................6
FRONT & REAR PANEL DESCRIPTIONS.................................................................................................................................7
FRONT PANEL VIEW ..............................................................................................................................................................7
REAR PANEL VIEW.................................................................................................................................................................. 8
SYSTEM OUTLINE VIEW................................................................................................................................................................9

3 | P a g e - Ver. 1.0 –11-22
SAFETY INSTRUCTIONS
BEFORE USING THIS EQUIPMENT
Read this manual and become familiar with safety markings and instructions.
Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts.
Verify the input AC voltage to the main power supply.
For a system with a digital controller option – DO NOT USE OR CONNECT a PoE enabled ethernet switch to a system.
Our digital controller does not support PoE connection and will cause permanent damages to a controller unit.
INTENDED USE
This product is intended for general laboratory use in a wide variety of industrial and scientific applications.
RF OUTPUT LOAD & PROPER GROUNDING REQUIRED
The RF output connector must be connected to a load before the AC switch is turned on.
AC & RF power must be off before disconnecting the output load or other components.
The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the
power cord.
REPAIR & MAINTENANCE
All repair or maintenance work must be performed by a factory authorized technician in order to extend the operating
life of this equipment and not to void any outstanding warranty.
FORCED AIR COOLING
This equipment requires forced air cooling. All air inlets and outlets must be cleared and free of blocking at all time.
Insufficient air flow will result in damaged equipment.
SAFETY SYMBOLS
This symbol is marked on the equipment when it is necessary for the user to refer to the manual for
important safety information. This symbol is indicated in the Table of Contents to assist in locating
pertinent information.
Dangerous voltages are present. Use extreme care.
The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent
damage, destruction or harm.
This symbol indicates protective earth terminal.

4 | P a g e - Ver. 1.0 –11-22
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS: 50Ω, 25°C
Parameter
Specification
Notes
Band
A
B
Operating Frequency Band
1 - 1000 MHz
1 - 6 GHz
Band switching @ 15 mS Max
Power Output @ Psat
30 Watt Min / 50 Watt Typ
CW or Pulse
Power Gain
45 dB Min
0dBm or less for rated Pout
Power Gain Flatness
4.0 dB p-p Max
Constant input power
Gain Adjustment Range
20 dB Min
Local or remote
Input Return Loss
-10 dB Max
2-Tone Intermodulation (IMD)
-30 dBc Typ
35dBm/Tone, Δ = 1MHz
Harmonics
<-20 dBc Typ
At rated Pout
Spurious
-60 dBc Max
Non-harmonics
Operating Voltage
100 - 240 VAC
47 - 63 Hz
Power Consumption
500 Watt Max
At rated Pout
Input Power Protection
+10 dBm Max1
Load VSWR Protection
6 : 1: Max2
Foldback @ preset limit
Sample Port (optional)
-40 dB
N-Female
1 Units with optional digital monitor and control, for basic units <10 Sec without damage
2 Units with optional digital monitor and control, for basic units <1 minute at rated Pout
ENVIRONMENTAL CHARACTERISTICS
Parameter
Specification
Notes
Operating Ambient Temperature
0 to +50 °C
Storage Temperature
-40 to +85 °C
Relative Humidity
up to 95 %
Non-condensing
Altitude
3000 meters
Shock & Vibration
Normal transport3
3 MIL Spec available for quotation
MECHANICAL SPECIFICATIONS
Parameter
Specification
Notes
Dimensions W x H x D
430 x 88 x 700 mm
2U, excluding handles
Weight
12 Kg.
RF Connectors Input/Output/Sample
N-Female
Front or rear panel
Interface Connector
9-Pin D-Sub
Rear panel
AC Power
IEC 60320-C14
Or equivalent
Cooling
Built in Fan Cooling
Variable speed
OPTIONAL: Digital Monitor & Control (DMC)
FWD, REV, VSWR, GAIN, ALC, V & I, TEMP,
Optional Safety Interlock (INT)
Ethernet RJ-45 TCP/IP, RS422/485, USB
Optional GPIB Interface
Open=STBY/Short=RFON
IEEE rear panel
BNC-F rear panel
e

5 | P a g e - Ver. 1.0 –11-22
OPERATING INSTRUCTIONS & GENERAL INFORMATION
INTRODUCTION
Advanced Amplifiers is an amplifier equipment and services company supporting commercial and government
organizations worldwide.
Headquartered in San Diego, California, the company utilizes its global network of resources to effectively serve and
support customer requirements.
As a unique original equipment manufacturer of power amplifiers ranging from 10KHz to 40GHz with various output
power levels for CW & pulse testing applications, we can also fully support custom designs and manufacturing
requirements for both small and large volume procurements. We bring decades of combined experience in the RF field
for numerous applications including and not limited to, EMI/EMC, communications, and various commercial and
industry standards.
With our in-house capabilities and fully equipped testing facilities, Advanced Amplifiers is committed to provide the
best in RF products with industry leading quality and lead times.
INCOMING INSPECTION
Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts.
Inspect all front and rear panel connectors for damage. Inspect fans and their airways for any damage or blockings. For
a unit with a digital controller option, the USB and ethernet interface and commands list is in the second part of the
manual.
RF & AC CABLE CONNECTION
RF Input and Output connectors are outlined in the specifications table. Use the standard AC cable that was supplied
by the manufacturer or higher power rating cables than the manual specifies. Refer to the front and rear panel
description page for the location of RF and AC connectors.
For a system with a digital controller option – DO NOT USE OR CONNECT a PoE enabled ethernet switch to a system.
Our digital controller does not support PoE connection and will cause permanent damages to a controller unit.
RF TURN ON PROCEDURE
Connect RF input to an RF Pulse Generator and Gating signal. Connect a suitable load for the power rated and
continuous operation to the output connector. Turn on the AC switch, display will show STANDBY. Optionally, connect
the unit to a digital control Software or Ethernet connection. Set the RF generator to nominal 0dBm and set the desired
frequency in the specified range. Select Gain or ALC and set to the desirable output power level then press the ONLINE
button. Use the front panel LCD gain adjust or the remote function to adjust the output power on the power meter
and the LCD screen to desired levels.
Refer to Appendix-1 for detailed operating instructions of the local and remote controller.
RF TURN OFF PROCEDURE
Decrease the RF drive from the RF generator to below -20dBm and press STANDBY on the LCD or via the control
software. Turn off AC switch on the front panel. Disconnect any unnecessary cable connections.

6 | P a g e - Ver. 1.0 –11-22
DECLARATION OF CE CONFORMITY
We, Advanced Amplifiers Corp, declare under our sole responsibility that the product to which this declaration relates
is in conformity with the following standard(s) or other normative document(s):
Council Directive 98/37/EC on the Safety of Machinery Directive
Council Directive 2014/35/EC on Low Voltage Equipment Safety
LIMITED WARRANTY
Advanced Amplifiers warrants that goods delivered hereunder, at the time of delivery, will be free from defects in
workmanship and material and will conform to the requirements of the purchase order. Seller’s liability hereunder
shall be limited to the repair or replacement of defective goods F.O.B. factory of which Seller is modified in writing by
Buyer within three (3) years following delivery thereof to Buyer, and in no event will Seller be liable for incidental,
special or consequential damages. (Note: One (1) year warranty for moving parts such as fans and power supplies).
The foregoing warranty is in lieu of all other warranties express or implied (except as to title), including any implied
warranty of merchantability or suitability for purpose or against infringement.
.
CONTACT INFORMATION
Please send all inquiries to:
Advanced Amplifiers
10401 Roselle Street
San Diego, CA 92121
WEB: WWW.ADVANCEDAMPLIFIERS.COM
EMAIL: SALES@ADVANCEDAMPLIFIERS.COM
COPYRIGHT & TRADEMARKS
Copyright 2022 Advanced Amplifiers, All rights reserved. All other trademarks and brand names are the property of
their respective proprietors.

7 | P a g e - Ver. 1.0 –11-22
FRONT & REAR PANEL DESCRIPTIONS
FRONT PANEL VIEW
No.
Title
Function
1
RF SAMPLE A
N Female, RF SAMPLE Connector.
SAMPLE PORT MUST BE TERMINATED AT ALL TIME
2
RF SAMPLE B
N Female, RF SAMPLE Connector.
SAMPLE PORT MUST BE TERMINATED AT ALL TIME
3
0dBm INPUT
N Female, 0dBm INPUT Connector.
4
FAULT LED
System Fault LED: Turn ON an LED when Over-Temp, Ext. Shutdown.
5
POWER SWITCH
System Power Switch.
6
LCD DISPLAY
4” Touch screen LCD Display, System Control LCD Panel.

8 | P a g e - Ver. 1.0 –11-22
REAR PANEL VIEW
No.
Title
Function
1
AC POWER CONNECTOR
AC Power Input 100 ~ 240VAC, 47/63Hz, IEC60320-14 Connector.
2
RS-422
System RS-422 Communication / Gating Signal Female 9-Pin D-Sub Connector.
P1 TX-
P6 N/C
P2 TX+
P7 N/C
P3 RX+
P8 N/C
P4 RX-
P9 N/C
P5 GND (RS-422)
3
GPIB
IEEE-488 GPIB Interface Connector, Female.
4
DEBUG
System Controller Debugging Female Connector.
Port access requires factory authorization
5
USB
USB Communication Connector, Type A Female.
6
ETHERNET
Ethernet Communication Female Connector, RJ-45.
For a system with a digital controller option – DO NOT USE OR
CONNECT a PoE enabled ethernet switch to a system. Our digital
controller does not support PoE connection and will cause permanent
damages to a controller unit.
7
INTERLOCK
BNC Female, Safety Interlock Connector
Interlock Close Circuit : Normal operation
Interlock Open Circuit : RF Off operation
8
GND
Frame Ground.
9
50Ω OUTPUT
N Female, 50Ω OUTPUT Connector.
10
Cooling FAN
System Outlet Cooling FAN.

9 | P a g e - Ver. 1.0 –11-22
SYSTEM OUTLINE VIEW
Table of contents
Other Advanced Amplifiers Amplifier manuals

Advanced Amplifiers
Advanced Amplifiers AA-20M1G-50 User manual

Advanced Amplifiers
Advanced Amplifiers AA-28G-2KW-PT User manual

Advanced Amplifiers
Advanced Amplifiers AA-10K250M-150 User manual

Advanced Amplifiers
Advanced Amplifiers AA-1218G-3.5KW-PT User manual

Advanced Amplifiers
Advanced Amplifiers AMP2103P-LC User manual