AMCON EQ-6002 User manual

1-800-255-6161• Fax 1-800-397-0013
www.amconlabs.com
AMCON AUTOMATIC
CHART PROJECTOR
USER’S MANUAL
EQ-6002

Disclaimer...................................................................................3
1. Introduction............................................................................4
2. Safety Instructions.................................................................5
3. Operating Specifications.......................................................7
3.1 Conversion from “M” Notation to Snellen Notation......9
4. Names of the parts.................................................................10
4.1 Names of the parts on the projector body.....................10
4.2 Remote Controller............................................................11
5. Operating Procedures ...........................................................12
5.1 Preparation .......................................................................12
5.2 Operation of the remote controller.................................13
5.3 Using the program function ............................................14
5.4 Carrying out program base examinations .....................16
5.5 Using charts to measure binocular functions...............17
6. Maintenance and Care...........................................................19
6.1 Daily Maintenance............................................................19
6.2 Replacing the projection lamp (bulb).............................20
6.3 Replacing the fuse ...........................................................23
6.4 Changing the channel setting of the remote control....24
7. Troubleshooting.....................................................................25

Amcon Auto Chart Projector
3
Disclaimer
Amcon: The Eyecare Supply Center makes no representations or warranties, either
expressed or implied, with respect to the contents hereof and specifically disclaims any
warranties, merchantability or fitness for any particular purpose. Further, Amcon: The
Eyecare Supply Center reserves the right to revise this publication and to make
changes from time to time in the contents hereof without obligation of this company to
notify any person of such revision or changes.

Amcon Auto Chart Projector
4
1. Introduction
Thank you for purchasing the Amcon Auto Chart Projector.
Please read these instructions and keep this manual in a convenient location for future
reference.
The remote controlled Amcon Auto Chart Projector is used to test eyesight employing
the principle of optical imaging. Additionally, by projecting charts on the screen and
changing the shape and size of the charts, spherical power, cylinder power and
accommodation balance can be tested. These same techniques can be used to
determine the quality of glasses.
The Amcon Auto Chart Projector provides operational convenience in a high quality
instrument.

Amcon Auto Chart Projector
5
2. Safety Instructions
To ensure safe use of this product, it is important that you follow the instructions
outlined in this manual as well as the warning notices on the instrument.
•Please read this user’s manual before you operate your projector. Save this user’s
manual for future reference.
•Do not look directly into the projector lens during operation. The intense light beam
may be harmful to your eyes.
•To avoid damage, always place this device on a stable stand. This instrument is not
designed to sustain rough treatment or falls.
•To reduce the risk of electric shock, do not disassemble this appliance. Take it to a
qualified technician when service or repair is required. Incorrect re-assembly can
cause malfunction of the projector or electric shock when the appliance is
subsequently used.
•Never attempt to replace the lamp assembly or any electronic component unless the
instrument is unplugged from the power source.
•Always open the lens shutter or remove the lens cap prior to turning on the projector
lamp.

Amcon Auto Chart Projector
6
•Avoid placing this projector in the following environments.
•Poorly ventilated or confined locations. Place at least 2 inches (50 cm) from
walls and allow free flow of air around the projector.
•Locations where temperatures may become excessively high, over 90°F (32°C).
•Locations with excessive humidity, dust, or cigarette smoke.
•Do not place any objects on projector.
•Avoid placing liquids near the projector. If the projector does become wet,
immediately disconnect it from the power source.

Amcon Auto Chart Projector
7
3. Operating Specifications
Category of the charts
a) Tumbling “E” chart 0.1, 0.16, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.2, 1.5
and 2.0
b) Landolt “C” chart 0.05, 0.1, 0.16, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.2,
1.5 and 2.0
c) Number chart 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 1.0, 1.2 and 1.5
d) Fixed astigmatic chart
e) R and G chart
f) Polarized chart
g) Balance chart
h) Polarized crosshair
i) Children’s chart
j) Coincidence test
k) Worth four dot test
l) Stereo test

Amcon Auto Chart Projector
8
Refraction distance 1.5m---6m
Projection distance 1.5m---6m
Projection magnifications 30X (at 5m refraction)
Number of charts 30
Chart changeover 1 frame / 0.1 sec.
Number of masks Open 1, Horizontal line 5, Vertical line 8 Single
isolation 21, R and G 1
Mask changeover 1 frame / 0.1 sec.
Program step Max
Projection lamp 12V 50W (Halogen lamp)
Replacement bulbs are available from Amcon
Product number: RQ-6200.
Electricity AC 110V 60Hz
Power consumption 80W
Weight 13 lbs. 3 ounces
(6.0 Kg)
Dimensions 11 7/8” x 9” x 9 ½”
(300mm X 230mm X240mm)

Amcon Auto Chart Projector
9
3.1 Conversion from “M” Notation to Snellen Notation
"M" Snellen Snellen
Notation in Feet in Meters
2 20/100 6/30
1.6 20/80 6/24
1.4 20/70 6/21
1.2 20/60 6/18
1.0 20/50 6/15
0.8 20/40 6/12
0.6 20/30 6/9
0.5 20/25 6/7.5
0.4 20/20 6/6
0.2 20/10 6/3
0.1 20/5 6/1.5

Amcon Auto Chart Projector
4. Names of the parts
4.1 Names of the parts on the projector body
1) Top cover
2) Remote Sensor
3) Front panel
4) Lamp cover
5) Barrel screw
6) Projection window
7) Base
8) Power switch
9) Power socket
10

Amcon Auto Chart Projector
4.2 Remote Controller
The names of the parts are shown as follows.
1) Remote Signal Emitter
2) Chart Switches
3) Light Switch
4) Reset Switch
5) Program Forward Switch
6) Program Back Switch
7) Highlight Selectors
8) Highlight Transfer Selectors
9) R/G switch
10)Program switch (this switch is used
when activating the ‘program’ mode, to
select P-1 or P-2)
11

Amcon Auto Chart Projector
5. Operating Procedures
Caution: Do not tilt the projector or place in an unstable place. The
projector may topple over, drop or cause injury.
Warning: Connect the power plug to a properly grounded three-prong
AC outlet. If it is connected to an ungrounded outlet, fire and/or
electrical shock may result.
Caution: Handling the power plug with wet hands can cause electric
shock.
5.1 Preparation
1. Place the instrument approximately level to the person to be tested.
2. Turn the power switch ‘off’.
3. Insert the power cord into the power socket on the projector body and plug into
the wall outlet.
4. Turn the power switch ‘on’.
5. Remove the battery cover from the back of the remote controller.
6. Insert batteries into the remote controller as illustrated and replace the battery
cover.
7. Adjust the position of the projector so that the projector light is centered on the
screen. Be sure the projector is in the position from which it will be used.
8. To focus the projector, slide the focusing knob that is found on the underside of
the projector base. (The same side as the lamp cover.) There is a barrel screw
that must be loosened before the knob can be moved. The enclosed Allen
wrench can be used to loosen or tighten this screw.
12

Amcon Auto Chart Projector
13
5.2 Operation of the remote controller
1. Turn the projector’s power switch on. The chart will automatically reset to the
start position and the lamp will light.
2. When using the remote controller, point the remote signal emitter in the direction
of the remote sensor on the front of the projector.
3. The switch functions are as follows
a) Chart Switches Projects the indicated chart on the switch.
b) Light Switch Turns the lamp off and on.
c) Reset Switch Returns to chart 1 of the program.
d) Program Forward Switch Fowards the program automatically.
e) Program Back Switch Reverses the program automatically.
f) Highlight Selector Isolates chart characters. (Horizontal Line of
Characters, Vertical Line of Characters, Single
Character).
g) Highlight Transfer Selectors Moves the isolation of the characters in the
direction indicated.
When the highlighted area of a chart being projected advances to the maximum
or minimum on that chart, the next or previous chart in the sequence will
automatically appear. Charts can be switched within the same type.
h) R&G Switch Applies the R&G filters to the designated charts.
i) Program Switch Refer to the Program Procedure, section 5.3, for
using this function.
Note: The projector will automatically turn off if not in use for 5 minutes.

Amcon Auto Chart Projector
14
5.3 Using the program function
1. How to program the Projector
1. Starting the Programming. Getting in the programming mode.
a) Turn on the power switch. The projector goes into initialization state.
b) Press the “RESET” button on the remote control.
c) Press the “R and G filter” button on the remote control.
d) Press the “Reset” button again on the remote control.
The projector will beep twice after pressing each button in “1b, 1c, 1d”. After the
third button, the projector will be in programming mode.
At any time up to step “d”, pressing any other button will return the projector to
normal operating state.
2. Select Program 1 or 2
Press the “P1/P2” switch to select program 1 or 2. The beeper will sound once if
program 1 is selected and twice if program 2 is selected.
3. Selecting Charts for the Program
a) Press the “program up” button to open the position for the first chart.
b) Select the desired chart button along with the desired “highlight” button.
c) Press the “program up” button again to enter the selection and move to open
the next position of the program. The beeper will sound four times. Repeat
steps 3a, 3b, 3c to enter other charts. Up to 30 selections are possible.

Amcon Auto Chart Projector
15
4. Completing the Program
a) When finished entering, press the “Reset” button to exit.
b) Press the light switch to turn off the projector.
5. Using the Program
a) To use a program, select program P1 or P2 by pressing the “P1/P2” button.
The beeper will indicate the program selected by sounding once for P1 and
twice for P2.
b) Press the “Program Up” button to run the program. The “Program Up” and
“Program Down” buttons will advance or reverse the program.

Amcon Auto Chart Projector
5.4 Carrying out program base examinations
16

Amcon Auto Chart Projector
5.5 Using charts to measure binocular functions
17

Amcon Auto Chart Projector
18

Amcon Auto Chart Projector
19
6. Maintenance and Care
6.1 Daily Maintenance
1) Cover the projector when not in use. This instrument is sensitive to dust
contamination.
2) Turn the power switch off when not in use. It is also recommended to unplug this
instrument when not in use for longer periods of time.
3) Keep projector clean by wiping the outside panels with a dry cloth. To remove
more difficult stains, a damp cloth with a mild detergent may be used. A mild
glass cleaner may be used on the outside panels. Be careful not to dampen the
inside parts of the projector.
4) When the lens is dirty, wipe it lightly with a good quality, dry micro-fiber cloth. An
Amcon “Vista Cham” is recommended.

Amcon Auto Chart Projector
6.2 Replacing the projection lamp (bulb)
Caution: To avoid electric shock, unplug the power cable when
replacing the projection lamp.
Caution: Do not replace the projection lamp immediately after turning
off the light. The lamp may still be hot and could lead to burns.
1) Turn the power switch off.
2) Remove the lamp cover screw and remove the cover.
20
Other manuals for EQ-6002
1
Table of contents
Other AMCON Projector manuals