Installation Instructions
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Proximity Infection
Control Faucet
Certified to comply with ASME A112.18.1M
© 2011 American Standard
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: sensor@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (855) 752-9259 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
M 9 6 5 11 9 R E V. 1. 3
Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ,s
Replacement Parts
1
2
2-3
4-6
7-8
9
10
6055 / 6056 / 6057 Infection Control Faucet shown Installed on
American Standard 9118.111 Infection Control Sink
6055.193
6056.193
6057
MODEL NUMBERS
.193
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.

6.Y-Connector
7. 4" Deck plate ( optional must be ordered separately)
8. 8" Deck plate ( optional must be ordered separately)
9. Mixing Valve ( optional must be ordered separately)
1. Selectronic Spout Assembly
2. Mounting Kit
3. Electrical Enclosure
4. Supply Hose
5a. DC Power Supply (for 6055 series)
5b. AC Power Supply (for 6056 series)
All American Standard Faucets Are Water Tested At Our Factory.
Some Residual Water May Remain In The Faucet During Shipping.
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.To ensure
that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
How to order the Selectronic Product
1. Choose Power Supply
2. Choose Desired Spout • Single Hole Sink
• Single Inlet
• 1 and 3 Hole Sinks
• Single Inlet
• 1 and 3 Hole Sinks
• Hot and Cold Inlets
Base Product Deck Plate (optional) Mixing Valve (optional)
1. R e m ov e t h e fi t t i n g a n d l o o s e i te m s f ro m t h e c a r t o n . T h e i l l u s t r a t i o n b e l o w s h o w s t h e f i tt i n g a n d a l l l o o s e i t e m s
after they have been removed from the carton. Some items may be packaged partially assembled to other items.
605P400
605P800
605XTMV
PRODUCT No.s
1
2
12
10
11
7
8
9
4
3
Deck Plate Mixing ValveBase Product
5" GN Spout
M 9 6 5 11 9 R E V. 1. 3
6055.193
6056.193
6057.193
Installation Instructions
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Proximity Infection
Control Faucet
Certified to comply with ASME A112.18.1M
© 2011 American Standard
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: Sensor@americanstandard.com
For Parts, Service,Warranty or other Assistance,
please call (855) 752-9259 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
M9 6 5 1 19 R E V. 1. 3
Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ,s
Replacement Parts
1
2
2-3
4-6
7-8
9
10
6055.193
6056.193
6057
MODEL NUMBERS
6055 / 6056 Infection Control Faucet shown Installed on
American Standard 9118.111 Infection Control Sink
10. Installation Instructions
11. 10 ft. Extension Wire (6057 series)
12. 27" Extension Wire (for 6057 series)
DO NOT REMOVE PROTECTIVE
FILM FROM SENSOR EYE UNTIL
INSTALLATION IS COMPLETE.
.193
6
5b
5a
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.

RECOMMENDED TOOLS
1Channel Locks
2Adjustable Wrench
3Plumbers' Putty or Caulking
4Phillips Screwdriver
5Flat Blade Screwdriver
6Electric Drill & 1/4"
Drill Bit
7Tape Measure
1
2
3
4
5
6
7
INSTALL SPOUT ASSEMBLY;
Fig. 1
INSTALLATION
CAUTION Turn off hot and cold water
supplies before beginning
10'
1
114mm
(4-1/2)
500mm
(20") 1524mm
(60)
413mm
(16-1/4)
3/8" COMP.
32mm
(1-1/4) DIA.
125mm
(4-7/8)
81mm
(3-3/16)
60mm
(2-3/8) MAX.
MOUNTING
SURFACE
Roughing-in Dimensions
(243mm)
9-9/16"
(127mm)
5"
(133mm)
5-1/4"
GENERAL DESCRIPTION:
Electronic faucet with proximity operation. Vandal
resistant solid brass construction single post
mounting. Operates on DC (battery) or AC
permanent power. In-line strainer for solenoid is
integral. Single inlet 3/8 compression, built-in
checks, and flexible stainless steel 16-1/4" reach
inlet hose for spout connection.
1. Connect the two 27" EXTENSION CABLES (1) to
the Faucet Sensor Cables. Fig. 1.
2. Insert 27" EXTENSION CABLES (1), FLEX HOSE
(2) and SPOUT SHANK (3) through center hole of
mounting surface. Fig. 1.
3. Assemble "C" WASHER (4), STAR WASHER (5)
and LOCKNUT (6) onto threads of SPOUT SHANK (3)
from underside of mounting surface. Fig. 1a.
4. Align FAUCET and tighten LOCKNUT (6). Fig. 1a.
Note: 4" and 8" Deck Plates are available for other
installations, see page one for information.
Fig. 1a
Fig. 1
2
M 9 6 5 11 9 R E V. 1. 3
11
23
4
5
6
3
(53mm)
2-1/8" DIA.
SENSOR
CABLES
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.

Fig. 2
3-3/4"
(96mm)
2-3/4"
(71mm)
3"
(76mm)
6
4
5
2
2
3
1
1
MOUNTING
BRACKET
SUPPLIES
WASTE
ENCLOSURE
MOUNTING
HOLES
3
1524mm
(60)
20"
(500mm)
MOUNTING
BRACKET
NOTE: If using Mixing Valve (optional) See Sheet
#M968808 for installation instructions.
1. For installation on Infection Control Sink mount
ENCLOSURE (1) on MOUNTING BRACKET (2) with
SCREWS (3).
2. For all other sinks or countertops determine location of
ENCLOSURE (1). It must be located within the 14"
(356mm) by 21" (533mm) shaded area shown in Figure 2
in order for electrical connections from the spout
assembly to be completed.
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance
between wall supply and ENCLOSURE (1) must be
taken into consideration.
3. Remove 4 screws from COVER (6) and pull off COVER
(6). Hold the ENCLOSURE (1) in desired location and
mark the four mounting hole locations as shown. Fig. 2.
4. The ENCLOSURE (1) works best if secured to a wall
stud or cross brace within the wall, using the SCREWS (4)
supplied. If the ENCLOSURE (1) is to be installed on a tile
or plaster wall the ANCHORS (5) and SCREWS (4)
should be used. Fig. 2.
5. For installations on drywall or tiled walls; use
ANCHORS (5) and SCREWS (4) for securing
ENCLOSURE (1) to finished wall. Drill four 1/4" dia. holes
a minimum of 1-3/4" deep. Insert the four ANCHORS (5)
flush with face of the finished wall.
Align the ENCLOSURE (1) and Install the MOUNTING
SCREWS (4). Tighten to secure ENCLOSURE (1) to
mounting surface.
NOTE. The illustration shows the Infection Control
FAUCET mounted on the American Standard Infection
Control Sink. Faucet can be installed on almost any sink
or countertop. For Faucet installation on the American
Standard Infection Control Sink, see instruction sheet
No. 7301793-100 (Infection Control Sink System) supplied
with Sink for more detailed information.
NOTE: For AC installation see “AC VERSION; Fig. 2.”
Make power supply connection before mounting
ENCLOSURE (1) to wall.
MOUNT ENCLOSURE; Fig. 2
2
1. Connect SUPPLY NUT (1) from spout assembly to
nipple on top of ENCLOSURE (2). Tighten with adjustable
wrench to make a water tight connection. Fig. 3.
NOTE; If using the optional Mixing Valve See Sheet
#M968808 for installation instructions.
CONNECT SPOUT HOSE TO
ENCLOSURE; Fig. 3
CONNECT WATER SUPPLY TO
ENCLOSURE AND WALL SUPPLY;
Fig. 4
3
Fig. 3
4
1
2
1
3
3
Fig. 4
2
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
ENCLOSURE (2).
2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to
FLEXIBLE SUPPLY HOSE (3). Tighten to make a water tight
connection. Use two wrenches to tighten if necessary. Fig. 4.
3. Connect FLEXIBLE SUPPLY (3) directly to wall supply.
Connection on FLEXIBLE SUPPLY (3) is 3/8" compression.
Use adjustable wrench to tighten connection. Do not over
tighten. Fig. 4a.
Note: FLEXIBLE SUPPLY (3) measures 20" from the bottom
of the ENCLOSURE (1) base. If additional supply length is
required, installer must purchase parts separately. Important:
If FLEXIBLE SUPPLY (3) is too long, loop to avoid kinking.
COLD WATER OR
TEMPERED
WALL SUPPLY
OTHER SINK
INSTALLATION
Fig. 4a
4
M 9 6 5 11 9 R E V. 1. 3
14"
(356mm)
21"
(533mm)

4M 9 6 5 11 9 R E V. 1. 3
1. Remove ENCLOSURE COVER (1). Fig. 1.
2. Feed the EXTENSION CABLES (2) from the Faucet
through the top of ENCLOSURE (3). Fig. 1a.
3. Install BATTERY (4) if not already installed, make
sure the shape of the BATTERY (4) follows the shape of
the BATTERY HOLDER (5). Fig. 1b.
4. Insert the BATTERY CONNECTOR (5a) through
GROMMET (6) as shown. Fig. 1c.
5. Connect SOLENOID CABLE (7) and BATTERY
CONNECTOR (5a) to EXTENSION CABLES (2) from
Faucet Sensor. Fig. 1d.
6. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.
DC VERSION (BATTERY); Fig. 1
1
ELECTRICAL INSTALLATION
Fig. 1a Fig. 1b
Fig. 1
Fig. 1c
5a
7
2
Fig. 1d
2
3
1
4
5
INSTALL BATTERY
CR-P2
5a
5a
6
5
CAUTION: Use only American Standard supplied
cable sets. Using non-AS supplied cables, or
cutting, splicing or modifying any components will
void the warranty.

5M 9 6 5 11 9 R E V. 1. 3
AC VERSION; Fig. 2
2
CAUTION Before opening ENCLOSURE
disconnect AC power supply.
NOTE: For AC installation see Fig. 2b.
Make power supply connection before mounting
ENCLOSURE (1) to wall.
1. Remove ENCLOSURE COVER (1). Fig. 2.
2. Feed the EXTENSION CABLES (2) from the Faucet
through the top of ENCLOSURE (3). Fig. 2a.
3. Remove SPLIT PLUG (4) from POWER SUPPLY
GROMMET (5). Insert POWER CORD (7) into SPLIT
PLUG (4). Insert POWER CORD CONNECTOR (6)
through POWER SUPPLY GROMMET (5). Push SPLIT
PLUG (4) into POWER SUPPLY GROMMET (5) to seal.
Fig. 2b.
4. Insert POWER CORD CONNECTOR (6) through
GROMMET (8) as shown.
5. Connect SOLENOID CABLE (9) and POWER CORD
CONNECTOR (6) to EXTENSION CABLES (2) from
Faucet Sensor. Fig. 2d.
6. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.
Fig. 2a
Fig. 2
Fig. 2c
6
9
2
Fig. 2d
2
3
4
7
5
Fig. 2b
6
1
6
8

M 9 6 5 11 9 R E V. 1. 3
6
FOR AC-VERSION
(MULTI HOOK-UP); Fig. 3, 3a, 3b
3
NOTE: For AC installation see “AC VERSION; Fig. 2b.”
Make power supply connection before mounting
ENCLOSURE (1) to wall.
1. Remove COVERS from all ENCLOSURES (2). Fig. 3.
2. Remove SOLID BLACK INSERT (5) from left side of all
ENCLOSURES (2), except from Unit #1. Replace with
GRAY GROMMET (9). (Supplied with each Faucet). Fig. 3.
3. All Units: Connect the two 27" EXTENSION CABLES
(4) to the Faucet Sensor Cables. Feed the 27"
EXTENSION CABLE CONNECTORS (1, 1a) from the
Faucet through the top of ENCLOSURE (2). Fig. 3a.
4. Connect one 27" EXTENSION CABLE (1) to the
SOLENOID (3). Fig. 3, 3a. Connect the second 27"
EXTENSION CABLE (1a) to the top of the
Y-CONNECTOR (8).
5. Connect the 10 ft. EXTENSION CABLE (6) to the top of
the Y-CONNECTOR (8). Feed the other end through the
two GRAY GROMMETS (9) and connect to the bottom of
the next Y-CONNECTOR (8). Place Y-CONNECTOR (8)
into ENCLOSURE (2) as shown Fig. 3a, 3b.
6. Repeat Steps above for each additional Unit, for a Max.
of 15 Units on one POWER SUPPLY (7). Fig. 3.
7. Replace ENCLOSURE COVERS. Tighten cover screws
firmly.
Unit #1
Unit #1
Unit #2 Unit #3
Fig. 3
Fig. 3a
1a
8
6
AC POWER SUPPLY
AC POWER
SUPPLY
10 ft. EXTENSION
CABLE
10 ft. EXTENSION
CABLE
FAUCET WIRE
CONNECTORS
4
SENSOR
CABLES
3
7
2
1
5
5
6 6 6
8 8
9
5
9
FAUCET WIRE
CONNECTORS
FAUCET WIRE
CONNECTORS
6
6
8
9
Fig. 3b

7M 9 6 5 11 9 R E V. 1. 3
TEST INSTALLED FAUCET
TO ENSURE A LAMINAR WATER FLOW the air must
be slowly purged from the spout. To do so, cover the
SENSOR (1) while slowly opening the water supply
valves. When the water flows as a solid, smooth,
steady stream, uncover the SENSOR (1) and fully
open the water supply valve. Fig. 1.
Fig 1
DETECTION
ZONE
1
MAINTENANCE
When the Sensor detects a user, the water
immediately starts to flow. Water flow will stop Two
seconds after user is out of sensor range. The off delay
allows the user to comfortably move his hands without
the flow cycling on to off. As a precaution, a safety
timer will turn off the water, after the sensor has been
blocked for 59 seconds. The water will stay off until the
blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
HANDWASH SENSOR OPERATION;
Fig. 1
1
1. Remove COVER from ENCLOSURE (1). Fig. 3.
2. Remove old BATTERY (2). Install new BATTERY (3)
making sure the terminal side is inserted first and
shape of the battery follows the shape of the
BATTERY HOLDER (4). Fig. 3.
3. Replace ENCLOSURE COVER. Tighten cover
screws firmly. Fig. 3.
HOW TO INSTALL AND CHANGE
BATTERY; Fig. 3
3
1. Setting the Detection Zone (Distance):
Remove cover from ENCLOSURE. Disconnect Power
Supply (1), then reconnect. Fig. 2.
2. While the SENSOR CONTROL LED (2) is blinking
slowly, place your hand 1 - 2 in. (30-50mm) in front of
the sensor. Fig. 2a.
3. When the LED stops blinking and stays "ON", move
your hand to the desired position and hold in place until
the LED begins to blink again. Fig. 2a.
4. Once the SENSOR CONTROL LED (2) begins to
blink again, remove your hand from the detection zone.
When the flashing stops, the detection distance is set.
5. Replace ENCLOSURE COVERS (2). Tighten cover
screws firmly.
HOW TO CHANGE SENSOR
RANGE; (Factory set at 6") Fig. 2
2
Fig.3
Fig. 2
Fig. 2a
BLINKING LED
UP TO 10" (250mm)
1
CR-P2
CR-P2
4
1
6
2
3
2
BLINKING
LED
2
1" - 2" (30mm - 50mm

8
1. Remove SET SCREW (1) with FLAT BLADE
SCREWDRIVER (2). Pull off SPOUT (3) from faucet
base. Fig. 5 & 5a.
2. Remove HOUSING (4) and remove FLOW
RESTRICTOR (5). Fig. 5b.
3. Rinse clean FLOW RESTRICTOR (5). Reassemble
and install into SPOUT BASE (6). Reassemble SPOUT
(3) onto SPOUT BASE (6) and tighten SET SCREW (1).
Fig. 5.
HOW TO CLEAN AND REMOVE
THE FLOW RESTRICTOR; Fig. 5
5
M 9 6 5 11 9 R E V. 1. 3
1
2
3
4
Fig.5
Fig.5a
Fig.5b
REMOVE SET SCREW (1)
PULL UP TO
REMOVE SPOUT
3
6
4
5
1. Remove ENCLOSURE COVER.
2. Close SUPPLY STOP (1) with 4mm Hex wrench.
Note: Keep water flowing out of faucet while shutting off.
3. Unthread STRAINER (2) using a 7/16" socket.
4. Pull out the STRAINER (2) and clean with an old
toothbrush. Rinse thoroughly with water.
5. Install the STRAINER (2) back in its place and
tighten with a 7/16" socket.
Caution: do not over tighten strainer.
Note: It is recommended to clean strainer every 6
months.
6. Open SUPPLY STOP (1) with 4mm Hex wrench.
7. Replace ENCLOSURE COVER. Tighten cover
screws firmly.
HOW TO CLEAN FILTER; Fig. 4
4
Fig.4
CAUTION Before opening ENCLOSURE
disconnect AC power supply.
3
1
2
7/16" SOCKET
CLEAN
SCREENS
4mm HEX WRENCH

FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted by
pause, replace battery, or call (855) 752-9259.
Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but turns
off when in sensor range?
A: Sensor wires to solenoid are reversed.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.
9
CAUTION
GENERAL CLEANING; Fig. 6
1. For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2. For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface. Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.
6
Fig.6
M 9 6 5 11 9 R E V. 1. 3

M 9 6 5 11 9 R E V. 1. 3
This manual suits for next models
2
Table of contents
Popular Kitchen & Bath Fixture manuals by other brands

Kohler
Kohler K-15265 Installation and care guide

Akuaplus
Akuaplus CLARA RC62025BLC user manual

JACLO
JACLO Aqua Legato installation instructions

Signature Hardware
Signature Hardware CARIN 949843 quick start guide

Inta
Inta IR500CP Installation and maintenance instructions

ProFlo
ProFlo PFWSC6860CP installation instructions

Helvex
Helvex FC-110-32 installation guide

Moen
Moen INS10608 installation guide

Kohler
Kohler Symbol K-19774 installation guide

Hansa
Hansa HANSAMINACOR 0747 Series Mounting and operating instructions

Spectrum Brands
Spectrum Brands Pfister Arkitek RT6-5LPM Quick installation guide

DURAVIT
DURAVIT C.1 Series Mounting instructions