Inta IR500CP User manual

Infra Red Basin Tap
IR500CP & IR501CP
Installation and Maintenance Instructions
In this procedure document we have endeavoured to make the
information as accurate as possible.
We cannot accept any responsibility should it be found that in
any respect the information is inaccurate or incomplete or
becomes so as a result of further developments or otherwise.
Intatec Ltd
Airfield Industrial Estate
Hixon
Staffordshire
ST18 0PF
Tel: 01889 272 180
Fax: 01889 272 181
email: [email protected]
web: www.intatec.co.uk
© Intatec Ltd 2020

© Intatec Ltd 2020 1
Introduction
This installation guide has been produced for the IR500CP & IR501CP infra red basin taps.
These instructions cover the installation, operation and maintenance. Please read the enclosed
instructions before commencing the installation of this product, please note;
We recommend that the installation of any Inta product is carried out by an
approved installer.
Products
Infra red basin mounted tap with battery box IR500CP
Infra red basin mounted tap with electronic transformer IR501CP
Check Contents
Before commencing remove all components from packaging and check each component with
the contents list.
Ensure all parts are present, before discarding any packaging. If any parts are missing, do not
attempt to install your Inta electronic tap until the missing parts have been obtained
Item Qty Components
11Tap with infra red sensor
2 1 Horse shoe sealing washer
3 1 Horse shoe metal washer
4 2 Securing nut
5 2 Threaded rod
6 1 Copper tail
7 1 Solenoid valve
8 1 Filter sealing washer
9 1 Sealing washer
10 1 Tap to valve (7) connector
11 1 Tap to electrical supply
connector
12 1 Battery holder or
transformer
13 2 Screws & wall plugs
Water
supply
1
2
12
13
8
3
7
9
10
11
6
4
5

© Intatec Ltd 2020 2
Check Contents
Technical Data
Power specification: 6V low voltage system
Power source - IR500CP: 4 x 1.5V CRP2 batteries
IR501CP: 230V transformer
Operating water pressure: 1.0 to 8.0 bar (14.5 to 116 psi)
With water pressure in excess of 8 bar use
with a pressure reducing valve.
Max. recommended water pressure: 5.0 bar
Hot water temperature: 5 to 65˚C maximum - To limit the outlet
temperature to 41˚C max. we recommend
using the Intamix Thermostatic Mixing Valve
code 40015CP.
Self opening after last water flow: Every 24 hours
4 x 1,5V (AA)
Alkaline
10
To electricity
supply
Transformer
230 V

© Intatec Ltd 2020 3
Pre-installation Information
Warning
Do not install the tap facing a mirror or any other electronic system operated by an infra red
sensor.
This tap is also vulnerable to stray sensor readings from users wearing high visibility or other
reflective clothing.
To prevent reflection problems, it is recommended to keep a minimum distance of 1.5m
between the tap and other objects.
Preparation for installation
Flush the water supply pipes thoroughly prior to installation. Do not allow debris, PTFE tape or
any metal particles to enter the tap.
Do not expose to temperatures below 5˚C, for example during winter. If the tap will be
exposed to freezing conditions the tap and system should be drained.
Important: All plumbing is to be installed in accordance with applicable codes and
regulations.
Dimensions
72
63
G½B
162
80
90
Ø49
G½
Ø45
Ø69

© Intatec Ltd 2020 4
Installation
1. A service valve should be installed in the water supply pipe to the valve should
maintenance be required in the future.
2. Turn off the water supply using the service valve (not supplied).
3. Screw the two threaded rods (5) and copper tail (6) into the base of the tap.
4. Install the tap (1) to the basin using sealing and metal (2 & 3) horse shoe washers and the
securing nut (4).
5. Connect the copper tail (6) to the solenoid valve (5) using the gasket (9). Ensure the flow
through the solenoid valve will be in the correct direction with flow to the tap, as marked
on the solenoid valve.
6. Connect the solenoid to the water supply using the filter washer (8). Failure to fit the filter
washer can damage the solenoid valve and invalidate the product warrantee.
6. Fix the power supply unit to the wall using the wall plugs and screws provided.
7. Connect the signal cable to the tap by assembling connector (10).
8. Turn on the water supply and check all joints for leakage.
9. Isolate via the service ball valve and tighten or remake joints if leakage occurs.
Connecting the power supply
1. Check that the sensor window is clean and that there are no obstructions in front of the
window.
2. Insert batteries into the battery box or connect the transformer to electricity supply.
3. Connect the power supply to the tap by assembling connector (11).
4. The LED under the sensor window will start flashing, when it stops the tap is ready for use.
IMPORTANT:
This product must be installed by a suitably qualified and competent person carrying the
relevant current IEE electrical qualification.
Sensor Range
The sensing range of the tap is preset and should not require adjustment.
If however the range needs to be adjusted it can be, using the following procedure;
• Unplug the power connector (10) or in the case of the transformer turn off the power
supply.
• Wait for 30 seconds before re-connecting or turning on the power supply.
• When the red LED blinks (if it switches off, it is necessary to unplug the power connector or
turn off the power supply and repeat the operation), put one hand immediately in front of
the sensor (at a maximum distance of 5cm).
• When the red LED lights up permanently, move your hand to the desired sensor distance.
• Wait for the LED to turn off before moving your hand; at this point the new distance is
stored.
• The new setting will be stored in case of battery replacement or failure of the electrical
supply.

© Intatec Ltd 2020 5
Prevention of Flooding
To prevent flooding the wash room following an act of vandalism or carelessness - an object left
in front of the sensor or dirty sensor, the tap has a safety device that shuts off the water flow
after approximately 1 minute.
Once the object has been removed or the sensor cleaned, the tap will start working again.
The model with the transformer unit has an automatic shut off which turns off the water
supply until the power supply is re-established.
Aftercare
• Inta taps have a high quality finish and should be treated with care.
• An occasional wipe with a mild washing-up liquid on a soft damp cloth followed by a
thorough rinsing is all that is required.
• Do not use an abrasive or chemical household cleaner as this may cause damage.
• Cleaning the sensor - the darkened window which protects the sensor must always be clean
in order for the tap to operate correctly; do not use abrasive material to avoid damaging
the plastic surface.
• Cleaning the water supply filter (8) - water can contain impurities which could damage the
solenoid valve. For this reason the inlet to solenoid valve has a gasket with an integral filter
which must be kept clean in order to ensure a suitable water flow.
CAUTION: turn off the water supply using the service valve before unscrewing
the joint to remove the filter gasket for cleaning.
Battery Replacement - IR500CP
When the batteries are exhausted, the LED blinks continuously and the solenoid valve stops in
the closed position, replace the batteries and recycle the used batteries correctly.
Warranty
Limited Warranty
This product is covered by a limited warranty for one year from the date of purchase.
During this period Intatec Ltd undertakes, at its option, to repair or replace any faults caused by
defective material or manufacturing faults that may arise (see Intatec Warranty).
This guarantee does not cover faults or damage caused by incorrect installation and/or
maintenance, wear and tear, battery or water composition (eg hard water), this includes but is
not limited to the following:
• Incorrect installation, inversion of supply pipes.
• Pressure or temperatures exceeding the recommended limits.
• Improper use, tampering, bad or lapsed maintenance.
• Foreign bodies, dirt or scale introduced by the water supply.

© Intatec Ltd 2020 6
Trouble Shooting
Problem Cause Solution
No water flow from tap
Check service valve is closed Open service valve
Exhausted battery - the LED
blinks Replace battery
Electrical problems
Check the voltage - where
needed
Disconnect and reconnected
the battery
Check the connector of the
power cable
Check the cable for damage
Damaged sensor - assistance
required
Dirty sensor - with vandalism
protection Clean the sensor window
Filter is dirty Close the service valve and
clean the filter
Blocked solenoid valve Assistance required
The water flows for 1 minute
without an object in front of
the sensor.
Dirty sensor Clean the sensor window
Light reflections on the sensor Remove the reflection source -
adjust the detection distance
Electrical problems Disconnect and reconnect the
battery
Water flows for more than one
minute
Blocked solenoid valve or
damaged sensor Assistance required
Self opening and closing of
the tap without user’s presence Light reflection on sensor Remove the reflection source -
adjust the detection distance
The water flows without the
tap being activated
Self opening function every 24
hours from last operation
Eliminates the risk of stagnant
water

© Intatec Ltd 2020
Intatec Ltd
Airfield Industrial Estate
Hixon
Staffordshire
ST18 0PF
Tel: 01889 272 180
Fax: 01889 272 181
email: [email protected]
web: www.intatec.co.uk
E & O.E
23-10-10
To active your product warranty please visit
www.intatec.co.uk
and click on Product Registration
Please leave this Manual for the User
This manual suits for next models
1
Table of contents
Other Inta Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

baliv
baliv KV-4050 manual

Sani-Lav
Sani-Lav 2004 operating manual

Speakman
Speakman SBS-2142 installation instructions

JADO
JADO Classic Victorian 865/708 Series installation instructions

Hans Grohe
Hans Grohe AXOR Montreux 16535 Series Instructions for use and assembly instructions

Brizo
Brizo VUELO RP64473 quick start guide