ArcVision PIH-510 G User manual

All the safety and operating instructions should be read before the unit is operated.
The safety and operating instructions should be retained for future reference.
All warnings on the unit and in the operating instructions should be adhered to.
All operating and user instructions should be followed.
Only a qualified electrician should make electrical connections.
Do not use attachments not recommended by the product manufacturer as they may cause hazards.
All cable runs must be within permissible distance.
This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight
of the unit.
IMPORTANT SAFEGUARDS
SAFETY PRECAUTIONS
1. Read Instructions
2. Retain Instructions
3. Head Warnings
4. Follow Instructions
5. Electrical Connections
6. Attachments
7. Cable Runs
8. Mounting
CAUTION
RISK OF ELECTRIC SHOCK
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT OPEN COVER.
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
to constitute a risk of electric shock to persons.
the literature accompanying the unit.
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears
to have been damaged in shipment, replace it properly in its carton and notify the shipper.
Be sure to save:
1. The shipping carton and packaging material. They are the safest material in which to make future shipments
of the equipment.
2. This Installation and Operating Instruction.
If the unit ever needs repair service, the customer should contact our dealer or branch for authorization to
return and shipping instructions.
UNPACKING
SERVICE

INSTALLATION
Step 1 Separate The Housing and PSU Box
Untighten the screws
from PSU box
Untighten and pull out
the bolt from the hinge
Separate the housing
and PSU box
Untighten the screws
from PSU box and
open it. (Swan Neck)
Step 2 Install Power Supply Unit
Put the PSU into the
box
Tighten 2 screws to
fix the PSU
Put PSU into the box Put the clamp on PSU Tighten 2 screws to
fix the PSU
When use 24Vac power source:
When use 90~260Vac power source:
1

Drill 4 holes on desired
locations
Tighten 4 screws to fix the power box
(These four screws are not supplied.
User must prepare their own screws.)
Install the Power Box
2
Step 3
Drill holes on the
intended positions of
of the wall.
(Goose Neck)
Step 4 Connection
Outdoor Housing Connection
GND
NO
NC
COM
6
5
4
3
2
1
GND
TXDO-
TXDO+
TXDI-
TXDI+
RS-485 AlarmIn AlarmOutput
ACInputACOutputFastDome
Wiring
Fan&Heater
Wiring
DC12V Input VideoOutput
1. Connect AC / DC cables:
Untighten the left
knob, put the AC
power cable through
the hole and tighten
the knob
Connect the AC
power cable to AC
Input jack
Connect the AC
power cable(below)
to AC Output jack
Connect the DC
power cable(above)
to DC Input jack
70
70 50.8
50.8
45
10
8

Untighten the right
knob, put the Alarm
and RS-485 cables
through the hole and
tighten the knob
Connect the
telemetry control
(RS-485) to RS-485
Input
(TXDI+,TXDI-)
Connect the Alarm
input cable to Alarm
Input
(Alarm 1 & GND)
Connect the video
cable to output jack
2. Connect Video cable:
Untighten the middle
knob, put the video
cable through the hole
and tighten the knob
3. Connect Alarm, telemetry control (RS-485) and Video cables:
CAUTION
*
*
For better waterproofing, please use one cable with one knob only.
(Recommended)
When using two cables with one knob, please fill the seam between
cables with waterproof glu to make it waterproof.
Cable diameter for the knob : 5~12mm
3

4
Outdoor Housing for IP Series Connection
GND
NO
NC
COM
6
5
4
3
2
1
GND
TXDO-
TXDO+
TXDI-
TXDI+
RS-485 Alarm In AlarmOutput
ACInputACOutputFastDomeWiring
Fan&Heater
Wiring
DC12V Input
VideoOutput
RJ-45
1. Connect AC / DC cables:
Untighten the left
knob, put the AC
power cable through
the hole and tighten
the knob
Connect the AC
power cable to AC
Input jack
Connect the AC
power cable(below)
to AC Output jack
Connect the DC
power cable(above)
to DC Input jack
2. Connect RJ-45 and Video cables:
Connect the video
cable to output jack
Connect the network
cable to RJ-45 jack
Untighten the middle
knob, put the video
and RJ-45 cables
through the hole and
tighten the knob

CAUTION
*
*
For better waterproofing, please use one cable with one knob only.
(Recommended)
When using two cables with one knob, please fill the seam between
cables with waterproof glu to make it waterproof.
Cable diameter for the knob : 5~12mm
3. Connect Alarm, RS-485, cables:
Untighten the right knob,
put the Alarm and RS-485
cables through the hole
and tighten the knob
Connect the telemetry
control (RS-485) to RS-485
Input (TXDI+,TXDI-)
Connect the Alarm input
cable to Alarm Input
(Alarm 1 & GND)
5
Step 5 Attach the Base to Housing
Turn the dome cover
anti-clockwise
Separate the dome
cover from camera
Untighten the 3
screws from base

6
Turn the camera body
anti-clockwise
Separate the camera
body and base
Unplug the
connection cable
Attach the base to
housing
Connect the housing
cable
Tighten 3 screws to
fix base
Setting Fast Dome ID
Setting Alarm Mode
Setting Camera Function
Setting Fan Power
Refer to FastDome operation manual for camera setting
Step 6 Camera Setting
Step 7 Attach Camera Body and Base
Reconnect the
connection cable
Attach camera body
to base
Turn camera body
clockwise to high
position
Tighten the three
screws to fix the
camera body

7
Attach the dome
cover to camera
Turn the dome cover
clockwise to tight
position
Attach the cover to
housing
Tighten the 3 screws
to fix the cover
Step 8 Install The Dome Cover and Housing Cover
Connection Between Housing and FastDome
Attach the housing
back to PSU box
Insert the bolt into
the hinge and tighten
Connect the fan &
heater cable to pin
jack
Connect the Fast
Dome cable to
connection jack
Step 9 Attach PSU and Bracket
Step 10

8
Install the Power Box, Bracket and Housing
Step 11
Attach the bracket
and housing to the box
Tighten the 4 screws
to fix the bracket
Pendant
Attach the bracket
and housing to the box
Tighten the 4 screws
to fix the bracket
Wall Mounting
Swan Neck
Tighten the screws of
PSU box to fix the cover.

STRUCTURAL DRAWING
Pendant
274
477.5
270
70
Wall Mounting
270
70
204
405
312.5
367.2
9
Unit: MM
Swan Neck
200
270
320
650
225
500
685

OUT
DC12V
DC12V
IN
LINE
NEUTRAL
GND
GND
NEUTRAL
LINE
GND
NO
COM
NC
4
3
5
6
1
2
TXDI-
TXDI+
GND
TXDO+
TXDO-
VIDEO
OUT
TO
NEXT
FastDome Keyboard
TO
AC-IN
24Vac
Connect to
FastDome
SWITCH POWER
AC24V
Connect to
Heater and Fan
AC-IN
AC24V
AC-OUT ALARM
OUT
ALARM
IN
SWITCH POWER
AC90~260V or
GND
NEUTRAL
LINE
OUT
DC12V
DC12V
IN
LINE
NEUTRAL
GND
GND
NEUTRAL
LINE
GND
NO
COM
NC
4
3
5
6
1
2
TXDI-
TXDI+
GND
TXDO+
TXDO-
VIDEO
OUT
TO
NEXT
FastDome Keyboard
TO
AC-IN
24Vac
Connect to
FastDome
SWITCH POWER
AC24V
Connect to
Heater and Fan
AC-IN
AC24V
AC-OUT ALARM
OUT
ALARM
IN
SWITCH POWER
AC90~260V or
GND
NEUTRAL
LINE
TO IP
10
WIRING DIAGRAM
Outdoor Housing
Outdoor Housing for IP Series

Outdoor Housing for IP Series
Model No.
Fan Activation
Construction
PIH-510 L
Steel
DC12V
700mA (Fan + Heater)
RS-485 In (2 inputs) RS-485 Out (2 outputs)
Alarm-In (6 inputs) Alarm-Out (3 outputs)
On +15 C OFF +25 C
270mm( ) x 297.5mm(H)f
5Kg
Dimension
Weight
Aluminum
Type
Brocket
Top
Internal Fixing
Wall Mounting
PIH-510 H
Pendant
Housing
Polycarbonate
Connection
PCB
Input Voltage
Current Consumption
RS-485
Alarm
Flame Resistant ABS
Heater Activation
On +35 C OFF +25 C
4.8Kg
Model No.
Fan Activation
Construction
Steel
DC12V
700mA (Fan + Heater)
RS-485 In (2 inputs) RS-485 Out (2 outputs)
One RJ-45 for Ethernet (10 Base-T)
On +15 C OFF +25 C
270mm( ) x 297.5mm(H)f
Dimension
Weight
Aluminum
Type
Brocket
Top
Internal Fixing
Housing
Polycarbonate
Connection
PCB
Input Voltage
Current Consumption
RS-485
RJ-45
Flame Resistant ABS
Heater Activation
On +35 C OFF +25 C
Alarm-In (6 inputs) Alarm-Out (3 outputs)
Alarm
11
SPECIFICATION
Outdoor Housing
PIH-510 G
Swan Neck
10Kg
PIH-510 L
5Kg
Wall Mounting
PIH-510 H
Pendant
4.8Kg
PIH-510 G
Swan Neck
10Kg
66-510CSE-5
This manual suits for next models
1
Table of contents
Popular Enclosure manuals by other brands

Fusion
Fusion ENCOUNTER EN-AB1120 quick start guide

StorCentric
StorCentric Nexsan E48X Removal and Replacement Guide

HP
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage... user guide

Vimar
Vimar LINEA 30784 Series quick start guide

Kaman
Kaman SERIES 8000 Reference manual

Lindy
Lindy 42901 user manual