protection plug and cover.
•The hose must not be bent. Before starting using the heater, each season, check the tightness of the hose and gas
connections and the date of expiry of the hose: in case of replacement, use only hose certified according to applicable
EN-standard, length 50 cm.
•If not provided, gas pressure regulator must be compliant with standard EN16129 (flowrate: max 1kg/h) and
gas hose with applicable EN-standard.
•VVERTENZE IMPORTANTI per l’utilizzo e lo stoccaggio
The heater is equipped with triple safety device:
1. ODS : turns off the unit when the % of C02 in the atmosphere exceeds the permitted limits;
2. PPF : automatically stops the gas supply if the pilot light off;
3. Anti-tilt: automatically blocks the gas supply in case of shock with reversal risk.
The heater turns off if there is not enough ventilation in the room: in this case, ventilate well the room and wait 10 minutes
before trying to turn it on again.
MAINTENANCE
To grant economical and smooth operation over time, we have prepared the following table for simple interventions, before
contacting after sales service.
Malfunction
a) The heater provides just a little heat.
b) The heater provides too much heat.
c) The heater emits odours.
d) The pilot goes out during operation
and turn off the heater.
e) The pilot doesn’t turn on by the
piezo-electric.
Possible cause
- Check that the hose is not kinked.
- Make sure the pressure regulator delivers
pressure of 30 mbar for G30 (Butane) and
37 mbar for G31 (Propane).
- Check if the gas in cylinder is finishing.
- None of these causes.
- Check if the pressure regulator delivers a
pressure higher than 30 mbar for G30
(Butane) and 37 mbar for G31 (Propane).
- Gas leakages on various connections or
hose, regulator without gasket.
- The gas in cylinder is finishing.
- The cylinder contains too many acids.
- None of these causes.
- In the room there is more than 1,2% by
volume of carbon dioxide.
- You are high on the mountains.
- The pressure regulator provides pressure
above 30 mbar for G30 (Butane) and 37
mbar for G31 (Propane).
- The nozzle of the pilot is dirty.
- The ignition electrode is not positioned
correctly.
- Cable disconnected from the button or from
the candle.
- None of these causes.
Suggested Actions
- Replace the pressure regulator 30 mbar
for G30 (Butane) and 37 mbar for G31
(Propane).
- Change the cylinder.
- Contact After Sales Service.
- Replace the pressure regulator 30 mbar
for G30 (Butane) and 37 mbar for G31
(Propane).
- Sprinkle with a brush and soapy water
all the connecting joints for leaks.
- Replace the cylinder.
- Replace the cylinder.
- Contact After Sales Service.
- Ventilate the room for a few minutes,
then turn on again.
- Contact After Sales Service.
- Replace the regulator.
-Contact After Sales Service.
- Bring the electrode above the pilot
mouth at a distance from the bulb of the
thermocouple of 3 / 4 mm, so that the
spark ignites the gas of the pilot.
- Reconnect the cable or turn on the pilot
with a match and contact After Sales
Service.
- Contact After Sales Service.
The heater requires minimal maintenance. Occasionally clean it with a soft, dry cloth. Never use abrasive powders
or solvents. Wait until the unit is cold. It is recommended that the heater be serviced every year by a competent
person in accordance with the Gas Safety (installation and use) Regulations.