ASCOM CR3 User manual

INSTALLATION AND OPERATION MANUAL
CR3, CR5, and CR7 Charging Racks

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
Abbreviations and Glossary
Abbrevations
DHCP Dynamic Host Configuration Protocol
A protocol for automating the configuration of computers and handsets that
use TCP/IP.
Device Manager Application for management of handsets, charging racks, etc.
LAN Local Area Network
USB Universal Serial Bus: a serial bus standard to interface devices, for example
connect computer peripherals such as mice, keyboards, scanners etc.
WinPDM Portable Device Manager (Windows version)
Used for managing devices, such as editing parameters and upgrading
devices. WinPDM is a stand-alone application installed on a computer. It is
used for small sites as it requires physical access to the handsets.
TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
Contents
1 Introduction 1
1.1 Technical Solution...............................................................................................................2
1.2 Interfaces ...........................................................................................................................3
1.3 Safety ................................................................................................................................3
1.4 Regulatory Compliance Statements (EU and EFTA only)..........................................................4
1.5 Regulatory Compliance Statements (UK only) ........................................................................4
1.6 Regulatory Compliance Statements (USA and Canada only)....................................................4
2 Charging Rack Installation 5
2.1 General..............................................................................................................................5
2.2 Placing on a Table...............................................................................................................6
2.3 Wall Mounting.....................................................................................................................6
2.4 Electrical Installation............................................................................................................7
2.4.1 Install Single Unit ...................................................................................................7
2.4.2 Install Multiple Units ...............................................................................................8
2.5 Communication Cable Connection....................................................................................... 11
2.6 Software Installation.......................................................................................................... 12
3 Charging Rack Configuration 13
4 Commissioning 14
5 Charger Operation 15
6 Maintenance 16
6.1 Operation when the Charger Rack is Connected to WinPDM/Device Manager........................ 16
6.2 Software Update............................................................................................................... 16
6.3 Easy Replacement............................................................................................................. 16
6.4 LED Indications................................................................................................................. 16
7 Troubleshooting 18
8 Related Documents 19
9 Document History 20
TD 92480EN / 17 August 2021 / Ver. M

Introduction
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
1 Introduction
This document describes how to install, configure and operate CR3, CR5, and CR7 charging racks. This
document is also intended to be used as a guide for maintenance and troubleshooting.
CR3 charging rack is used for Ascom IP-DECT and VoWiFi handsets while CR5 and CR7 charging racks are
used to charge Ascom Myco™ handsets1.
CR3 charging rack is available in two different models (advanced and basic), while CR5 and CR7 charging
racks are only available as a basic model. The advanced charging rack can be used to program and charge
handsets, while the basic version can only be used to charge handsets. CR3 and CR5 charging racks can
charge up to six handsets simultaneously, while CR7 charging rack can charge up to five handsets at the
same time.
To get more information on the charging rack model features, refer to the tables below.
Table 1 Charging rack features
Model Features
Advanced charging rack — Charging slots for handsets.
— Ethernet and USB connection used for upgrade
and configuration of handsets and charging racks
(through a LAN or PC connection).
Basic charging rack — Charging slots for handsets.
Table 2 Variants of charging racks
Item. No. Model Charges the handsets
CR3-AAAC Advanced charging rack — Ascom d81
CR3-AAAD Advanced charging rack — Ascom d81
— Ascom d43
— Ascom d63
— Ascom d83
CR3-ABAC Basic charging rack — Ascom d81
— Ascom i62
CR3-ABAD Basic charging rack — Ascom d81
— Ascom d43
— Ascom d63
— Ascom d83
— Ascom i62
— Ascom i63
1TD 92480EN / 17 August 2021 / Ver. M
1. Ascom Myco is a trademark of Ascom (Sweden) AB.

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Introduction
Table 2 Variants of charging racks (continued)
CR5-AAAA Basic charging rack — Ascom Myco
— Ascom Myco 2
CR7-AAAA Basic charging rack — Ascom Myco
— Ascom Myco 2
— Ascom Myco 3
Supply voltage: 100-240VAC/0.7A 50/60 Hz
Building fuse for fixed installation: 10 A max
Installation Alternatives
In the USA and Canada the charging rack can only be installed as a single unit, serial configuration
is not permitted.
• The charging rack can be installed as a single unit. When installed as a single unit, the power cord with
the C14 connector can be used together with a suitable extension cord, and can be plugged into a wall
outlet. Up to four advanced charging rack single units can be connected to one LAN outlet.
• If more than one charging rack is used in a serial configuration a fixed installation must be made. For
safety reasons it is NOT allowed to supply more than one unit by the power cord with the C14 connector.
When units are supplied in series, the installation must be made by an authorized electrician and the C14
connectors must be removed. Maximum five units can be connected in serial power supply , but LAN
serial connection is limited to four units..
In Sweden, Norway and Finland a connection to protective earth (safety grounding) must be
provided.
1 1 Technical Solution
The following functionality is provided by a charging rack:
Model Charger functionality
Advanced Charging Rack — Charging of the handset battery.
— Provide a means for software and parameter
update of handsets.
Basic Charging Rack — Charging of the handset battery.
The USB port on the advanced charging rack is used to connect the charging rack to a Device Manager or
to a PC running the Portable Device Manager (WinPDM). Device Manager or WinPDM can be used to
configure or upgrade either the charging rack itself or any handsets placed in the charging rack.
The Ethernet ports can be used to connect up to four advanced charging racks to a single LAN outlet.
The advanced charging rack is designed to be always connected to an Ethernet based LAN.
TD 92480EN / 17 August 2021 / Ver. M 2

Introduction
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
If the Ethernet connection is used, each advanced charging rack needs an IP address. See label
for MAC address.
If the advanced charging rack is connected to the WinPDM via both USB and Ethernet, the USB
connection has higher priority.
To get more information on how to connect charging racks using the Ethernet and USB ports, refer to 2.5
Communication Cable Connection, page 11.
Charging rack is equipped with a combined reset button and embedded LED on the front of the charger.
For the basic charging rack, the button/LED has no function.
1 2 Interfaces
The requirements stated below are only applicable to the advanced charging rack.
Computer
• Windows 7® Professional (32-bit/64-bit), Windows 7® Enterprise (32-bit/ 64-bit), Windows 7® Ultimate (32-
bit/64-bit), Windows 8/8.1® Pro (32-bit/64-bit), Windows 8/8.1® Enterprise (32-bit/ 64-bit), Windows 10® Pro
(32-bit/64-bit), Windows 10® Enterprise (32-bit/ 64-bit).
• Sun Java Runtime Environment (JRE) version 6 or higher.
• USB port. USB 1.1 required, USB 2.0 supported.
• Ethernet port 10/100 Mbit/s.
1 3 Safety
The charging rack is connected to 100-240VAC/0.7A 50/60 Hz.
For safety reasons:
• the safety covers on top of the supply voltage terminal blocks must be mounted to prevent hazardous
situations, such as an electric shock.
• when servicing the units the mains power supply cable must be disconnected.
For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device shall be
incorporated into the building installation wiring. The disconnect device shall disconnect both
poles.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be
easily accessible.
In US and Canada a permanent connection of equipment to the mains supply by a power supply cord is not
permitted.
In Sweden, Norway, Finland, and Denmark the charging rack must be connected to a wall outlet with
protective earth (safety grounding). For other countries it is recommended to use a protective earth
connection.
3TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Introduction
• Suomi: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.
• Norge: Apparatet må tillkoples jordet stikkontakt.
• Sverige: Apparaten skall anslutas till jordat uttag.
• Danmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord som giver forbindelse til stikprop-
pens jord.
1 4 Regulatory Compliance Statements (EU and EFTA only)
This equipment is intended to be used in the whole EU & EFTA.
This equipment is in compliance with the essential requirements and other relevant provisions of EMC
Directive 2014/30/EU, LVD Directive 2014/35/EU and of Directive 2015/863 (RoHS3) amending 2011/65/EU.
The complete Declaration of Conformity is found at https://www.ascom-ws.com/doc/.
The product is marked with
1 5 Regulatory Compliance Statements (UK only)
This equipment is in compliance with the essential requirements and other relevant provisions of
Electromagnetic Compatibility Regulations 2016, Electrical Equipment (Safety) Regulations 2016, and the
Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations
2012.
The complete Declaration of Conformity is found at https://www.ascom-ws.com/doc/.
The product is marked with
1 6 Regulatory Compliance Statements (USA and Canada only)
FCC Compliance Statements
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
CAN ICES-3 (B)/NMB-3(B)
Modifications
Changes or modifications to the equipment not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
TD 92480EN / 17 August 2021 / Ver. M 4

Charging Rack Installation
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
2 Charging Rack Installation
2 1 General
The unit shall be installed by authorized personnel only.
• The units shall be placed in a dry environment with a temperature range from +5° C up to + 40° C (41° F to
104° F).
• The units shall be mounted on a vertical wall.
• Avoid mounting the charging rack in a sunlit place. This can affect the charging capacity.
• Avoid mounting the charging rack where radio/network coverage is not sufficient. This can reduce the
messaging capacity.
• The unit can be mounted to a vertical wall (concrete or plaster walls only) no higher than 2000 mm or be
placed on table if table adapters are used.
• If the charging rack is connected to a power supply via an AC wall plug, serial power supply connection
is not allowed.
• If the charging rack is connected to a power supply via an AC wall plug, the socket-outlet shall be
situated near the equipment and shall be easily accessible.
• If the charging rack is connected to a power supply via a fixed connection, a readily accessible
disconnect device shall be incorporated in the building installation wiring.
Delivery Includes
• Charging rack
• Power supply cord including IEC C14 connector (male)
• Inlet accessory kit including cable support holders and screws
• Table adapters
An extension cord IEC C13 AC connector (female, IEC60320-C13) to wall socket has to be ordered
separately. It shall be connected between the pre-installed IEC C14 AC connector (male) and the
wall socket.
Required Tools etc
• Screwdrivers
• Cutting pliers
• Multimeter
• Screws and wall plugs for wall mounting.
Make sure the screws and wall plugs have the correct length for the type of wall used.
5TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Charging Rack Installation
Table 3 Example of plug and screw dimensions
Wall material Plug length Screw diameter
Single plasterboard Thorsman TP1 3.5 – 5 mm
Double plasterboard Thorsman TP2 3.5 – 5 mm
Concrete Thorsman TP2 3.5 – 5 mm
Charging Rack Mounting
Different ways to mount the charging racks are shown in Figure 4. Examples of ways to mount charging
racks, page 8. It is possible to set up different combinations of charging racks and battery pack chargers. A
maximum of four advanced charging racks (or battery pack chargers) can be serially connected to the same
LAN source.
Installation Steps
The installation is done in the following way:
1. Placing on table or wall mounting, refer to 2.2 Placing on a Table, page 6 or 2.3 Wall Mounting, page 6.
2. Electrical installation, refer to 2.4 Electrical Installation, page 7.
3. If advanced charging rack is used, cable connection communication shall be established, refer to 2.5
Communication Cable Connection, page 11.
2 2 Placing on a Table
If the charging rack shall be placed on table, use the table adapters included in the delivery as follows:
1. Mount the two table adapters in the two outer holes in the bottom cover of the charging rack as shown
in the image below.
2. Mount the four rubber feet as shown in the image below.
Figure 1. Mounting of table adapters and rubber feet
Mount table
adaptor and
rubber feet
here.
Mount the rubber
feet here.
2 3 Wall Mounting
Charging rack shall not be mounted higher than 2000 mm.
Follow these steps when mounting a charging rack to a wall:
1. First, make an outline of how the charging racks are to be placed.
TD 92480EN / 17 August 2021 / Ver. M 6

Charging Rack Installation
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
If several charging rack (or battery pack chargers) are to be mounted close to each other, mount them
so that there is enough space between them to be able to disconnect the handsets (vertical distance)
and to be able to open the top cover (horizontal distance).
When you are planning the location of the modules, start to mount them in a height that makes it easy
to reach the handsets and to read the handsets’ display.
2. Measure and mark the drill holes by using the dimensions in Figure 2. Mounting dimensions in mm.
Charging rack seen from the back, page 7.
3. Dill and fasten the charging rack on the wall with four screws.
Figure 2. Mounting dimensions in mm. Charging rack seen from the back
400
290
70.5
2 4 Electrical Installation
2 4 1 Install Single Unit
The charging rack is delivered with a cord with an IEC C14 connector (male). An extension cord IEC C13 AC
connector (female, IEC60320-C13) to wall socket has to be ordered separately. It shall be connected
between the pre-installed AC connector (male) and the wall socket.
Figure 3. Example of CR7- AAAA charging rack with IEC C14 connector and an extension cord with an IEC
C13 connector
For the advanced charging rack, connect the communication cable when required.
Installation Test
1. Connect the mains power supply cord to the wall socket.
7TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Charging Rack Installation
2. The LED on the front of the charger should light up.
The LED is disabled on the basic charging rack and will not light up. Put a handset into a
charging slot and check if the handset LED lights up.
2 4 2 Install Multiple Units
If the charging rack shall be connected with a fixed connection, the AC connection must be done
by a authorized electrician.
It is possible to use any of the two AC terminal blocks for AC input. Consequently, the unused terminal
block may be used to connect the next charging rack or battery pack charger.
The power supply module connects to 100-240VAC/0.7A 50/60 Hz. When working with the units the mains
power supply cable must always be disconnected. The safety covers must be mounted on top of the power
supply terminal blocks to prevent hazardous situations, like electric chock.
Figure 4. Examples of ways to mount charging racks
To disconnect device
To disconnect device
Fixed Installation in Details
Fixed installation of the first charger or single unit with fixed electrical installation.
1. Remove the C14 connector from the power cord. Measure, cut and strip the power cord to be
connected to the disconnect device.
2. Connect the mains power supply cord to the disconnected device.
The IEC color code is used in the power cord supplied.
Table 4 Wiring color codes
IEC US Old 1Load Also called
Brown Black Red Active Line, Hot
TD 92480EN / 17 August 2021 / Ver. M 8

Charging Rack Installation
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
Table 4 Wiring color codes (continued)
Blue White Black Neutral Return, Cold,
Grounded
connector
Gr/Ye 2Green Green Earth Ground, Safety
Earth, Earth
Ground,
Grounding
conductor 3
1. The "Old" standard was used in various countries (including Australia), and some wiring may still use these colors.
2. Gr/Ye - Green with Yellow stripe - this is the standard world wide, although it is not common in the US or Canada at present.
3. There is an important distinction between "Grounding conductor" (safety earth) and "Grounded conductor" (Neutral). These are
US terms for the conductors and they are not interchangeable, despite the similarity of the names
2 4 2 1 Installation of Additional Units
Do not connect more than five units in a power series. Serial power configuration is only allowed
for wall mounted charging rack, it is not allowed for charging racks used as a single desktop unit
placed on a table.
Do not connect more than four units to one single LAN outlet in a LAN series.
Important
It is not allowed to connect additional charging rack or battery pack chargers if the chargers
are connected to the power supply via an AC plug.
Important
Disconnect the power supply connection before working on the units.
1. If the additional charging rack has not yet been mounted on the wall, do this according to instructions
in 2.3 Wall Mounting, page 6.
2. Open the top cover of the charging rack closer to the AC power source. Open the top cover by first
pressing on the sides of the top cover, then lifting it upwards.
3. Remove the cover which protects the unused AC output terminal block of the charger closer to the AC
power source.
9TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Charging Rack Installation
4. Mount the cable support holder at the unused opening in the charger closer to the AC power source.
The cable support holder is provided in the parts bag.
5. Remove the C14 connector from the additional charger. Cut and strip the mains power supply cord
coming from the additional charger to the length required.
6. Run the power supply cord from the additional charger through the cable support holder of the
previous charger.
7. Connect the power supply cord from the additional charger to the unused terminal block in the charger
closer to the AC power source. Note the embossed markings L, earth symbol and N.
8. Mount the safety cover and fasten it with one screw.
9. Secure the mains power supply cable with two screws (2), which are provided in the parts bag.
10. Replace the top cover.
11. Fasten the power cord to the wall depending on local regulations.
12. If more charging racks shall be connected, repeat the above steps 1-12 for the next unit.
TD 92480EN / 17 August 2021 / Ver. M 10

Charging Rack Installation
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
Installation Test
1. When the fixed installation is completed, apply AC power by switching on the disconnect device.
2. The LED on the front of each charger should light up.
The LED is disabled on the basic charging rack and will not light up. Put a handset into a
charging slot and check if the handset LED lights up.
2 5 Communication Cable Connection
This section is applicable to the advanced charging rack only.
The communication cable connections are situated under the top cover of the charging rack.
Figure 5. Communication connections inside the charging rack
LAN PC USB
When connecting several (up to four) charging rack over the Ethernet, it is possible to connect them in
series using the two Ethernet connections. Power over Ethernet is not supported.
Figure 6. Connecting charging racks in series using Ethernet cables
LAN PC LAN PC
Rack Charger 1 Rack Charger 2
1. Open the top cover.
2. If a single charging rack is used, connect the Ethernet cable or USB cable to the connections shown in
Figure 5. Communication connections inside the charging rack, page 11. If several charging racks shall
be connected in series, connect the Ethernet cables to the connections shown in Figure 6. Connecting
charging racks in series using Ethernet cables, page 11.
3. Let the Ethernet/USB cables run on top of the cable support holders.
4. Close the top cover.
The USB Interface supports USB 2.0 Full speed. One Mini-B Receptacle USB connector is used. The USB
connection is used for communication with a PC. Power over USB is not supported.
The USB connection is used for connecting the charging rack directly to a PC or to a LAN for the purpose of
upgrading or configuring the charging rack itself or handsets placed in the charger.
11 TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Charging Rack Installation
2 6 Software Installation
This section is applicable to the advanced charging rack only.
The charger is delivered with pre-installed software and it is possible to upgrade the charger software, refer
to Portable Device Manager (PDM), Windows version, Installation and Operation Manual, TD 92325EN.
TD 92480EN / 17 August 2021 / Ver. M 12

Charging Rack Configuration
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
3 Charging Rack Configuration
This section is applicable to the advanced charging rack only.
Each charging rack needs an access to DHCP to receive an IP address automatically. If no DHCP is
accessible it is possible to configure with WinPDM.
If the charging rack is configured to run DHCP, connect the network cable and the charging rack will
automatically receive an IP address. If the charging rack is not configured to run DHCP the charging rack
will use the setup IP addresses.
The following parameters exist for the charging rack and can be changed via the WinPDM/Device Manager.
Parameter Description
Ethernet Bit rate1auto (default)
Ethernet connector1auto (default)
Ethernet duplex1auto (default)
DHCP Enabled Yes (default), No
Charger IP address 192.168.0.101 (default)
Subnet mask 255.255.255.0 (default)
Default gateway IP address 192.168.0.1 (default)
DNS IP address 192.168.0.2 (default)
Charger IP port 12346 (default)
Service Discovery Enabled Yes (default), No
Service Discovery Domain Name of domain
DH IP address (one DH only) 192.168.0.3 (default)
DH IP port 10147 (default)
1. Currently only "auto" setting is available.
Follow the steps below to set the charging rack parameters:
It may be necessary to import the parameter definitions file that is included in the software
package. The package is provided by your supplier. The WinPDM/Device Manager used may differ
from the version that is described here.
1. Check that the charging rack is connected to the WinPDM/Device Manager.
2. In the WinPDM/Device Manager, open the Numbers tab.
3. Select the charging rack that you want to change parameters for.
4. From the Number menu, select Edit.... The Edit parameters window opens.
5. Edit the required parameters.
6. Click OK.
13 TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Commissioning
4 Commissioning
The commissioning includes the following:
• Installation test, refer to Installation Test, page 7.
• Charging, refer to Charging, page 14.
• Communication with WinPDM/Device Manager, refer to Communication with WinPDM/Device Manager,
page 14.
Charging
To verify that the charging works, do as follows:
1. Check that the LED on the front of the charger(s) is lit.
The LED is disabled on the basic charging rack and will not light up. Put a handset into a
charging slot and check if the handset’s LED lights up.
2. Place a handset in a charging slot. Start of charging may be indicated differently depending on handset
model.
Communication with WinPDM/Device Manager
The communication test is applicable to the advanced charging rack only.
Refer to Figure 5. Communication connections inside the charging rack, page 11 to get more information on
the location of communication connections inside the charger.
Follow the steps below to start the WinPDM/Device Manager:
If you are using a Device Manager:
1. Check that the charging rack is connected.
2. Open a web browser and enter the URL to access the Device Manager.
3. Click Device Manager. The Device Manager window appears.
4. Go to the Devices tab and verify that the charging rack is online (it may take up to 15 sec).
If you are using the WinPDM:
1. Check that the charging rack is connected to your PC.
2. Start WinPDM.
3. Go to the Devices tab and verify that the charging rack is online.
For instructions on how to verify that the charger parameter settings work or how to upgrade the charger,
or for any further instructions, please refer to Portable Device Manager (PDM), Windows version, Installation
and Operation Manual, TD 92325EN.
TD 92480EN / 17 August 2021 / Ver. M 14

Charger Operation
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
5 Charger Operation
When the charger is connected to an external power supply, normal operation is done as follows:
Handset Charging
1. Connect the charger to the AC power supply.
2. Place a handset in the charging slot to start charging. Push the handset into the charger to fully insert it.
Handset Disconnection
1. Tilt the handset towards you.
2. Lift the handset upwards.
It is not recommended to lift the handset upwards before tilting it towards you.
15 TD 92480EN / 17 August 2021 / Ver. M

INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks Maintenance
6 Maintenance
Information in this section is applicable to the advanced charging rack only.
6 1 Operation when the Charger Rack is Connected to WinPDM/Device Manager
When the charger is connected the following additional operations can be done:
• Software upgrade (of charger or handset)
• Parameter editing (of charger or handset)
• Phonebook upload (handset)
• Language upload (handset)
For more information, refer to Portable Device Manager (PDM), Windows version, Installation and
Operation Manual, TD 92325EN.
6 2 Software Update
The charger software is pre-installed. Updates can be performed by using the WinPDM/Device Manager.
The software version of the charger can be checked as follows:
1. Open the WinPDM/Device Manager.
2. Open the Devices tab.
3. In the list of devices, find the charger.
4. The software version is shown in the Software version column.
For any additional details, please refer to Portable Device Manager (PDM), Windows version, Installation
and Operation Manual, TD 92325EN.
6 3 Easy Replacement
Not all handsets support easy replacement feature. For the details, please refer to an applicable
handset’s documentation.
The charging rack supports the easy replacement feature. Easy replacement is performed via the handset
display and does not involve WinPDM/Device Manager. The charging rack only needs a power connection
to support easy replacement. A connection to WinPDM/Device Manager is not needed.
6 4 LED Indications
The charger is equipped with a status LED. The following indications are used:
LED Indication Description
None Not connected to power.
Green, fixed Logged on to WinPDM/Device Manager.
Amber, fixed — Not logged on to WinPDM/Device Manager.
— Charging of handset.
TD 92480EN / 17 August 2021 / Ver. M 16

Maintenance
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
Amber, flashing (1000 ms on, 1000 ms off) — Software download.
— File transfer during easy replacement.
Amber, flashing (100 ms on, 800 ms off) Change phone indication during easy replacement.
Red, fixed Software error. Service needed.
Red, flashing (100 ms on, 800 ms off) Error indication during easy replacement. Put back
old handset in charger.
Charger returns to “Not logged in to WinPDM/
Device Manager” mode when handset is removed.
Red, flashing (3 long flashes, 800 ms on, 100 ms
off)
Parameter error in user parameters. Charger
performs a factory reset and restarts.
Red, flashing (800 ms on, 100 ms off) — Parameter error in production parameters.
Service needed for charger.
— Error during easy replacement. Service needed
for both handsets.
LED indications are also described in 7 Troubleshooting, page 18.
17 TD 92480EN / 17 August 2021 / Ver. M
Other manuals for CR3
2
This manual suits for next models
2
Table of contents
Other ASCOM Rack & Stand manuals