I
Warning!
Hazardous electrical current!
Ensure protection against
explosions!
Before installing
Switch off the power to the device.
Make sure that device cannot be
switched on again by accident.
Make sure that the device is de-
energized.
Connect to earth and short out.
Cover or close off any neighboring live
parts with a barrier.
Follow carefully the assembly
instructions provided for the device.
Only qualified personnel as per EN
50110-1/-2 (VDE 0105, part 100) can
perform any work on this
device/system.
The electrical connections are to be
made as per the relevant specifications
(e.g. cross-section of the supply line,
fuses, protective connection).
Opening the motor - save for the
terminal box - during the warranty
period without the manufacturer's
permission shall lead to the termination
of the warranty.
Original spare parts are to be used for
the approved repairs or repairs not
falling under the warranty.
Live and rotating parts of electrical
motors can cause major or deadly
injuries.
Any shipping, installation, start-up and
maintenance works are to be carried
out only by qualified personnel (follow
carefully any regulations on explosion
protection such as EN 60079-14 and
SeitenEN 50821-1-2 as well as any
other national accident prevention
regulations).
As regards any equipment subject to
these guidelines, it is important to adopt
the necessary safety precautions to
protect the personnel against possible
injuries.
The personnel must be duly instructed
to proceed with caution and according
to regulations during shipping, hoisting,
and positioning and while repairing the
motor.
Do not lift the motor together with the
drive equipment by the motor lifting
eyebolts.
Do not use the supplied lifting eye bolts
at ambient temperatures below –20°C,
in accordance with DIN 580. Lower
temperatures could lead to the ring
screws breaking and consequent
breaking and consequent injury to
personnel and/ or damage to the
installation.
Do not load the eyebolts as per DIN
580 no more than 45° compared to the
screwing direction. The use of
crossbeams is recommended. See the
operating instructions for the layout
dimensions of the lifting eyebolts and
the minimum dimensions of the loading
crossbeams and chain lengths.
In the case of motors with built-in brake
appropriate safety measures are to be
adopted against the possible failure of
the brake especially in applications
involving the pulling of loads.
Operating the motor with the supplied
shaft protection cover alone is
forbidden.
Contact with the capacitor for the start-
up and running of single-phase motors
is to be avoided until the unloading
procedure is carried out securely.
If a high-voltage test is necessary, the
procedures and precautionary
measures set forth in accident
prevention regulations are to be
followed.