Overview
The BAPI Electronic Technician Assistant enclosures are 14-gauge painted steel. NEMA 1 rated panels are available in a
wide range of sizes. BAPI provides a 44 x 20 x 8 inch NEMA 4X panel. No knockouts are provided; drill and punch where
you need conduit openings. Flipping the enclosure 180 degrees accommodates left or right hand door openings. The
NEMA 4X panel has mounting tabs, all other enclosures mount by drilling holes in the back to fit your application.
s
BAPI Part Number Size Empty Weight NEMA Rating
BA/44208N1S 44 x 20 x 8 inches 90 lbs 1
BA/44208N4XS 44 x 20 x 8 inches 95 lbs 4X
BA/32208N1S 32 x 20 x 8 inches 68 lbs 1
BA/20208N1S 20 x 20 x8 inches 47 lbs 1
Both 44 x 20 x 8 inch enclosures have two permanent dividers that provide a wireway for input and output conduit connec-
tions at the top of the enclosure and a high voltage compartment at the bottom of the enclosure for the power supply. Each
enclosure comes with a Large Backplate (BP185X285), a Small Backplate (BP6X185) and two Bracket Cable Guides (BCG).
The BAPI 32 x 20 x 8 inch enclosure has two permanent dividers that provide a wireway for input and output conduit connec-
tions at the top of the enclosure and a high voltage compartment at the bottom of the enclosure for the power supply. The
enclosure comes with a medium backplate (not sold separately), a Small Backplate (BA/BP6X185) and two Bracket Cable
Guides (BA/BCG).
The BAPI 20 x 20 x 8 inch enclosure has one field-installed divider that provides a high voltage compartment in the enclosure
to isolate a power supply. The enclosure
comes with a backplate and two Bracket
Cable Guides (BCG). Additional Bracket
Cable Guides may be purchased sepa-
rately to help you neatly place wire in the
enclosures.
Backplate mounting
studs, 4 typical per plate
Customer supplied
controllers
PAN16 Panduit Wire Duct
ETA modules in a TRK18
Snaptrack
Field Installed Divider
Customer supplied
transformer
PS17 Power Supply
Figure 1:
BAPI 20 x 20 x 8 enclosure
and medium backplate loaded
with a BA/PS17, ETA modules,
BA/PAN16 wire duct and two
controllers - showing the field
installed divider.
15557_Ins_NEMA
Building Automation Products, Inc., 750 North Royal Avenue, Gays Mills, WI 54631 USA
Tel:+1-608-735-4800 • Fax+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com
Electronic Technician Assistant NEMA Enclosures
2
Installation and Operation Instructions
12/9/11
rev.
Specifications subject to change without notice.
20 x 20 x 8 Enclosure - Backplate Hole Location/Guide
Pairs of holes for BCG Bracket Cable Guides
Row of holes for
TRK18 Snaptrack
Row of holes for PAN16
Panduit Wire Duct
Row of holes for divider
plate
Row of holes for power
supply snaptrack
Figure 2:
BAPI 20 x 20 x 8
enclosure and the
included backplate
showing hole locations.
Hole field for
customer supplied
transformer
The Medium Backplate is only supplied with BAPI’s 20 x 20 x
8 Enclosure and the hole pattern is shown above. Since you
may wish to rotate the enclosure for left or right door opening,
the divider plate is shipped loose.
After mounting the backplate in the orientation you desire
screw the divider to the indicated row of holes with the self-
tapping screws provided. Power supplies and customer supplied
transformers may be attached to the plate in the suggested
positions. TRK18 Snaptrack and PAN16 Panduit are accommo-
dated in the suggested positions. You may add any holes you
wish to the plate.
Figure 3:
Bracket Cable Guide (BCG) installation
Backplate
mounting studs,
4 typical per plate
15557_Ins_NEMA
Building Automation Products, Inc., 750 North Royal Avenue, Gays Mills, WI 54631 USA
Tel:+1-608-735-4800 • Fax+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com
Electronic Technician Assistant NEMA Enclosures
3
Installation and Operation Instructions
12/9/11
rev.
Specifications subject to change without notice.
44 x 20 x 8 Enclosure - Small & Large Backplate Hole Location/Guide
BP185X285 Large
Backplate
Figure 4:
BAPI 44 x 20 x 8 enclosure
showing Bracket Cable Guides,
Small & Large Backplates, Panduit
Wire Duct and Snaptrack.
Backplate mounting
studs, 4 typical per
Backplate
Row of holes for TRK18
Snaptrack
TRK18 Snaptrack
TRK18 Snaptrack
for power supply or
voltage converter
Built In Divider
Built In Divider
BCG Bracket
Cable Guides
Holes for
additional BCG
Bracket Cable
Guides
BP6X185 Small Backplate
Holes for controller
mounting
PAN16 Panduit
Wire Duct
Hole field for
customer supplied
transformer
The Large Backplate (BP185X285) has punched holes to mount a variety of
accessories, see Figure 4. As shown, at the bottom of the plate, are two
rows of holes for TRK18 Snaptrack and a row for a PAN16 Panduit Wire Duct.
Along the right edge are sets of holes for up to three Bracket Cable Guides
(BCGs). If you need the BCGs on the left side, rotate and mount the plate
that way. The upper half of the plate has random holes that can be used to
mount many different types of controllers. You may add any holes you wish
to the plate.
The Small Backplate (BP6X185) has punched holes to mount a variety of
accessories. As shown, holes are available for power supply snaptrack and
user supplied transformers.
15557_Ins_NEMA
Building Automation Products, Inc., 750 North Royal Avenue, Gays Mills, WI 54631 USA
Tel:+1-608-735-4800 • Fax+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com
Electronic Technician Assistant NEMA Enclosures
4
Installation and Operation Instructions
12/9/11
rev.
Specifications subject to change without notice.
Select a mounting location that conforms to the National Electric Code and local codes. BAPI recommends a minimum of
two 3/8 inch SAE grade 2 steel bolts to hold the enclosure to the mounting surface.
NEMA 1 Enclosures
Each backplate has four mounting studs welded into the enclosure to mount the backplate. Remove the four nuts and the
backplate. Drill through the back of the enclosure for your mounting fasteners. After attaching the enclosure to your
mounting surface place the backplate onto the studs in the desired orientation. Replace the nuts and torque to 16 foot-
pounds.
NEMA 4X Enclosures
Use the external mounting tabs to secure the enclosure to your mounting surface. DO NOT drill through the back of the
enclosure to mount it.
Note: Be sure to check local seismic codes for additional mounting requirements.
There are no conduit knockouts in any of the enclosures. Drill and punch for any conduit openings you require.
The Large Backplate (BP185X285) has punched holes to mount a variety of accessories, see Figure 4. As shown, at the
bottom of the plate, are two rows of holes for TRK18 Snaptrack and a row for a PAN16 Panduit Wire Duct. Along the right
edge are sets of holes for up to three Bracket Cable Guides (BCGs). If you need the BCGs on the left side, rotate and
mount the plate that way. The upper half of the plate has random holes that can be used to mount many different types of
controllers. You may add any holes you wish to the plate.
The Small Backplate (BP6X185) has punched holes to mount a variety of accessories. As shown, holes are available for
power supply snaptrack and user supplied transformers.
The Medium Backplate is only supplied with BAPI’s 20 x 20 x 8 Enclosure and the hole pattern is shown in Figure 2.
Since you may wish to rotate the enclosure for left or right door opening, the divider plate is shipped loose. After mounting
the backplate in the orientation you desire screw the divider to the indicated row of holes with the self-tapping screws
provided. Power supplies and customer supplied transformers may be attached to the plate in the suggested positions.
TRK18 Snaptrack and PAN16 Panduit are accommodated in the suggested positions. You may add any holes you wish to
the plate.
Mounting
Figure 5:
44X20X8 Overall and Mounting Hole Dimensions

This manual suits for next models

3

Popular Enclosure manuals by other brands

OWC data doubler installation guide

OWC

OWC data doubler installation guide

Sarotech W-31 Series installation guide

Sarotech

Sarotech W-31 Series installation guide

Schrack BEZ00112 operating instructions

Schrack

Schrack BEZ00112 operating instructions

Thermaltake V3 BlacX Edition VL800M Series user manual

Thermaltake

Thermaltake V3 BlacX Edition VL800M Series user manual

Northern Lights GEM Series Assembly instructions

Northern Lights

Northern Lights GEM Series Assembly instructions

RAIDAGE v7Age220-SAU user manual

RAIDAGE

RAIDAGE v7Age220-SAU user manual

DS18 HYDRO SLG-UDSD6 owner's manual

DS18

DS18 HYDRO SLG-UDSD6 owner's manual

Heckler Design WindFall FRONT MOUNT Assembly & installation

Heckler Design

Heckler Design WindFall FRONT MOUNT Assembly & installation

Akasa Integral LAN user manual

Akasa

Akasa Integral LAN user manual

CommScope AEKT instruction sheet

CommScope

CommScope AEKT instruction sheet

Fantec ER-35U3-6G quick start guide

Fantec

Fantec ER-35U3-6G quick start guide

Campbell ENC 10/12 product manual

Campbell

Campbell ENC 10/12 product manual

Sharkoon REBEL C70M manual

Sharkoon

Sharkoon REBEL C70M manual

zihatec ArduiBox MKR Series Construction manual

zihatec

zihatec ArduiBox MKR Series Construction manual

ACO SERVOKAT SMART installation manual

ACO

ACO SERVOKAT SMART installation manual

Guardian NZXT user manual

Guardian

Guardian NZXT user manual

Altinex CNK200 Cable-Nook user guide

Altinex

Altinex CNK200 Cable-Nook user guide

Bull ESCALA Series manual

Bull

Bull ESCALA Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.