User Notice
◆The total capacity of the indoor units which runs at the same time can not exceed 150% of
that of outdoor units; otherwise, the cooling (heating) effect of each unit would be poor.
◆A breaker (or fuse) needs to be installed in every indoor unit, and the capacity should be in
accordance with indoor unit’s electrical parameter; all the indoor units are required to be centralized
controlled by a main switch, this switch can cut off the electric power supply in case of emergency.
The breaker (or fuse) on each indoor unit has the function of preventing short circuit and avoiding
abnormal overload, it should be connected in normal situation. The main switch controls the power
supply of all the indoor units. Before cleaning and maintaining the indoor units, it is very important
to turn off the main power supply switch.
◆In order to turn on the units successfully, the main power switch should be opened 8 hours
before the operation.
◆It is a normal phenomenon that the indoor unit will still run for 20-70 seconds after the indoor
unit receives the "stop" signal so as to make full use of after-heat for the next operation.
◆ When the running modes of the indoor and outdoor units conict, it will be indicated on the
display of the wired controller in ve seconds and then the indoor unit will stop. At this time, change
the operation mode of the indoor unit to the one that would not clash with the outdoor operating
mode to make the operation normal. The HEAT mode conicts with each of the COOL mode, DRY
mode and FAN mode, while the COOL mode, DRY mode and FAN mode are compatible between
each other.
◆The appliance shall not be installed in moist places, such as laundry.
◆An all-pole disconnection switch having a contact separation of at least 3mm in all poles
should be connected in xed wiring.
◆Main switch is provided by end user. Main switch knob should be in black or gray, it can be
locked on “OFF” with padlock.
◆The instruction of main power switch should be included in user manual and the
recommended installing height should be at 0.6-1.7m. And also over current protection is required
(UL 1995,CSA C22.2).
◆ The outdoor ambient temperature of the unit under cooling mode ranges from -5~48°C DB.
The outdoor ambient temperature of the unit (only for the heat pump type unit) under heating mode
ranges from -15~27°C WB.
◆This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This product must not be disposed together with the domestic waste. This product has
to be disposed at an authorized place for recycling of electrical and electronic appliances.
Thank you for selecting Blueridge air conditioner. Before use, please read this manual
carefully and keep it properly for furthur reference.