Safety Precautions
In case the power cord of the water heater is
damaged, be sure to have it replaced by after service
technicians with special cord offered by the
manufacturer.
Check if the ammeter and the diameter of the wires are in
accordance with the rated current of the water heater. If
necessary please have it checked by experienced
electrician.
The product is only available for alternating current.
Be sure to use independent receptacle and earth it reliably.
The receptacle shall comply with the stipulation of
national standard.
The product adopts the patent ¡±"PTO 0" technology of Haier company. As long asadopting civil power supply,
even if the earthing wire iselectrified by mistake, the "PTO 0" technology still can block the dangerouselectricity,
and ensure your personal safety. But if you find perceptible current,please pull off the power plugand contact local
after service department for maintenance. Donot disassemble by yourself.
Description of the Symbols
Never do that
Be sure to act as per instructions
Set the receptacle of the water heater at dry
position away from water spraying. Do not insert
and pull the power plug with wet hands.
In winter of cold area, if the heater is idle for a long
period, please pull the handle of safety valve to discharge
the water.Otherwise it may freeze inside the water heater
and cause damages.
After installation, be sure tofill the heater completely with
water before switching on the power in the first usage.
Children must take bath under the supervision of adult.
In opening and closing the water valve, do not point
the shower head to human body. Otherwise it may
hurt by the spraying hot water.
Attentions in Installation
Safety precaution:
Do not confuse the water inlet and outlet pipe. The wall bearing the water heater
shall be strong enough to endure a weight twice as much as that of water heater
filled with water.
If any part is damaged, please contact the local maintenance agent, and have it
replaced with ourspare part.
Please fasten the drain hose to the drain thread
of safety valve by twisting (see to Figure 3).
Connect the other end of drain hose to the
sewer to avoid polluting the room by splashing.
When the power is switched on, and the water
heater starts operating, there may be some
water discharged from the pressure relief hole
of safety valve. It is due to the water expansion
under heating, and is normal phenomenon. The
pressure relief pipe shall communicate with the
air directly.Do not block it. The discharged
Connect to drain hose
Installation
The water may drip from the discharge pipe of the pressure relied device and
that this pipe must be left open to theatmosphere. Check safety valve once a
month as follow: move the small handle of safety valve, if there's water
flowing out, safety valve is normal; if there's no water flow, please contact
local after-sales service station.
The pressure relief device is to be operated regularly to remove lime
deposits and to verify that it is not blocked.
Water can be led to the sewer. The drain hose connecting to the safety valve
shall be keptdownward sloping in installation and in a frost-free environment.
Select suitable position on the wall to fix the shower nozzle bearer. Connect
the shower nozzle hose to the pipeline. Fasten the mixing valve. Check if
there's water leakageat each joint.
Be sure to check and confirm that the tank is filled with water, there's no
leakage at each joint and the power supply complies with the stipulation
before switching on the power.