Installation
Guide
UESI-LF
Watersaving
Urinal
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023
UESI-LF
Water Saving Urinal
A3
SHEET 2 OF 2
SCALE:1:10
TITLE:
DO NOT SCALE DRAWING
DATE
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
APPV'D
CHK'D
DRAWN
REVISION
Britex Metal Products Co. Pty Ltd.
ACN: 004 309 737
2 Mirra Ct, Bundoora Victoria 3083
P: 03 9466 9000 F: 03 9466 9044
britex.com.au [email protected]
Drawing:
AW
24/02/23
A
SD-2609.2
Sign
Date
Approval For Manufacture

Australia’s Finest Stainless | britex.com.au
About
Preparartion and Completion Notes
The BRITEX Watersaving Urinal is a great, vandal resistant water saving fixture that
incorporates the unique ‘Britex Waterless’ outlet requiring no costly replaceable cartridge,
bio block or sealant fluid. Instead, the ‘Britex Waterless’ outlet utilises a self-sealing one
way diaphragm that allows urine to pass, whilst trapping odours within the plumbing. To
assist with the regular maintenance regime, each Watersaving urinal is supplied with a
Britex Hygiene Clean that periodically activates a cleaning cycle to ensure the connected
plumbing is flushed and the unit itself is kept clean. WaterMark certified as required by
plumbing regulations and government legislation.
Britex urinals are approved for use as per the accompanying certifications and can be coupled with
cisterns, flush valves & sensor flushing systems according to specific model requirements. It is the
installer’s responsibility to ensure that the urinal is installed in accordance and to the regulations of
the residing governing authority and all applicable plumbing code regulations.
Britex Floor Mounted Urinal’s are fitted with a water spreader incorporating options of rear or top
mounted inlets (38mm (1.5”) & 25mm (1”)) to be nominated on placement of order. As a standard
practice 38mm (1.5”) inlets will be provided unless 25mm (1”) inlets are specifically requested.
1. 38mm (1.5”) Inlets: Are typically supplied to urinals that are to be flushed with cisterns or flush
valves. The urinals inlet supply fitting, consists of a nylon adaptor and flanged nut to suit 38mm
(1.5”) flush pipe tube, (copper, stainless steel etc). Alternatively, 40mm DWV PVC pipe can be
used by substituting the urinal nylon flange nut for a DWV PVC Adaptor Female Iron 40mm. If a
flushing devise is utilised with a smaller supply line, then the nylon inlet adaptor can be reduced
with appropriate fittings as long as the flushing device and supply requirements are in accordance
with the urinal specifications.
2. 25mm (1”) Inlets - Are typically supplied to urinals that are to be flushed with sensor flush
solenoids. The urinals inlet fitting is supply, consists of a 1” Male BSP T.O.E. nipple to suite 25mm
(1”) flush pipe tube connections with the use of a 1’ flange nut. Alternative supply lines utilising a 1’
BSP thread for connection to the urinals inlet may also be used as long as the flushing device and
supply requirements are in accordance with the urinal specifications.
A Discharge waste outlets vary dependent on nominated size received on order placement,
but generally consist of 50mm (2’), 75mm (3’”) & 100mm (4”) dependent on local plumbing
regulations.
As the urinal is to be fixed to the rear wall, ensure that the substructure will provide sufficient
support to the urinal. Complete any reinforcement works as necessary and provide noggins where
required. Use appropriate anchors suitable for use with the substructure to fix the urinal to the wall
surface.
Floor mounted urinals can be recessed and made flush with the finished floor level or mounted
directly onto the floor (Step Up). If the urinal is to be recessed, refer to the urinal trench dimensions
within this document.
The preparation of a slurry bed is part of the bedding down process for all urinal installations
inclusive of floor mounted and recessed urinals. Additional works, structural conformance, water
proofing etc. may be required to the substructure and should be investigated and approved by the
appropriate authorities. All preliminary works should be completed prior to the installation of the
urinal.
Protect the surface of the product during the installation process. Do not remove any PVC
coatings that may have been applied to the surface until the product has been commissioned and
ready to be used.
2
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023

Australia’s Finest Stainless | britex.com.au
UESI-LF Drawing
3
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023
FRONT ELEVATION
PLAN VIEW
Length As Required Up To 1400mm
40
15040
1050
50
40
15
320
40
WASTE & COVER
40
85
WASTE & COVER
(Rear entry shown)
115
40
R25 typ
Full length sparge cover
320
195
SECTION
150
DURAGAL 'C' channel
75 batter
205
and wingnut fired to
rear affixed with stud
is 75mm over height
Batter / Fall on face
rear of flutes
Ø38mm Inlet assembly
both horizontal
VITEL NYLON 66 compound
Full length 25 X 65mm
Tile lip to rear
and vertical edges
fabricated full from
55 70
1050
1100 Shallow max.
Overall height varies according to length
Ø50mm threaded waste
50
15
with waterless waste insert
assembly
300500
Not for tile lip to
130
=
=
FLUSH ENTRY POINT
Approval For Manufacture
Sign Date
Ø38mm
Ø25mm
Please tick the required option
Rear
Top
Water Saving Urinal A3
SHEET 1 OF 1 NTS
TITLE:
DO NOT SCALE DRAWING
DATE
APPV'D
CHK'D
DRAWN
ISSUE
Britex Metal Products Co. Pty Ltd.
ACN: 004 309 737
2 Mirra Ct, Bundoora Victoria 3083
P: 03 9466 9000 F: 03 9466 9011
AW
25/2/21
B
SD-2609
DRAWING:
UNLESS OTHERWISE SPECIFIED:
DINENSIONS ARE IN MILLIMETERS
UESI-LF
Inlet Size Inlet Point
FRONT ELEVATION
PLAN VIEW
Length As Required Up To 1400mm
40
15040
1050
50
40
15
320
40
WASTE & COVER
40
85
WASTE & COVER
(Rear entry shown)
115
40
R25 typ
Full length sparge cover
320
195
SECTION
150
DURAGAL 'C' channel
75 batter
205
and wingnut fired to
rear affixed with stud
is 75mm over height
Batter / Fall on face
rear of flutes
Ø38mm Inlet assembly
both horizontal
VITEL NYLON 66 compound
Full length 25 X 65mm
Tile lip to rear
and vertical edges
fabricated full from
55 70
1050
1100 Shallow max.
Overall height varies according to length
Ø50mm threaded waste
50
15
with waterless waste insert
assembly
300500
Not for tile lip to
130
=
=
FLUSH ENTRY POINT
Approval For Manufacture
Sign Date
Ø38mm
Ø25mm
Please tick the required option
Rear
Top
Water Saving Urinal A3
SHEET 1 OF 1 NTS
TITLE:
DO NOT SCALE DRAWING
DATE
APPV'D
CHK'D
DRAWN
ISSUE
Britex Metal Products Co. Pty Ltd.
ACN: 004 309 737
2 Mirra Ct, Bundoora Victoria 3083
P: 03 9466 9000 F: 03 9466 9011
AW
25/2/21
B
SD-2609
DRAWING:
UNLESS OTHERWISE SPECIFIED:
DINENSIONS ARE IN MILLIMETERS
UESI-LF
Inlet Size Inlet Point
FRONT ELEVATION
PLAN VIEW
Length As Required Up To 1400mm
40
15040 1050
50
40
15
320
40
WASTE & COVER
40
85
WASTE & COVER
(Rear entry shown)
115
40
R25 typ
Full length sparge cover
320
195
SECTION
150
DURAGAL 'C' channel
75 batter
205
and wingnut fired to
rear affixed with stud
is 75mm over height
Batter / Fall on face
rear of flutes
Ø38mm Inlet assembly
both horizontal
VITEL NYLON 66 compound
Full length 25 X 65mm
Tile lip to rear
and vertical edges
fabricated full from
55 70
1050
1100 Shallow max.
Overall height varies according to length
Ø50mm threaded waste
50
15
with waterless waste insert
assembly
300500
Not for tile lip to
130
=
=
FLUSH ENTRY POINT
Approval For Manufacture
Sign Date
Ø38mm
Ø25mm
Please tick the required option
Rear
Top
Water Saving Urinal A3
SHEET 1 OF 1 NTS
TITLE:
DO NOT SCALE DRAWING
DATE
APPV'D
CHK'D
DRAWN
ISSUE
Britex Metal Products Co. Pty Ltd.
ACN: 004 309 737
2 Mirra Ct, Bundoora Victoria 3083
P: 03 9466 9000 F: 03 9466 9011
AW
25/2/21
B
SD-2609
DRAWING:
UNLESS OTHERWISE SPECIFIED:
DINENSIONS ARE IN MILLIMETERS
UESI-LF
Inlet Size Inlet Point

Australia’s Finest Stainless | britex.com.au
Installation Instructions
1. Prior to installing the urinal ensure the substructure has been prepared to accommodate
all required services inclusive of supply lines, sanitary discharge connections and set
down trench for recessed urinals . Service locations are provided on the applicable model
diagrams within this document.
a. Rear inlet supply connections will require the provision of a permanent front or
rear access panel within the wall face to be provided above each inlet connection, or
alternatively, a temporary cavity that can be sealed on the completion of connections and
commissioning.
b. Sanitary discharge connections should be terminated at a height 20mm below the
underside of the urinal gutter. Terminating the discharge pipe with a pan collar fitted with
an internal rubber gasket is recommended.
2. On completion of the rough in process, place the urinal into position, ensuring the urinals
waste outlet spigot is in line and enters the discharge pipe without obstruction and the urinal
sits stable and flush to the rear wall.
3. Once in position and particularly with recessed urinal installations, preliminary checks and
adjustments should be carried out to ensure that the urinal is level and at the correct height.
a. Use the top of the urinal gutter’s front fascia edge to determine the level and height of
the urinal, taking into consideration and allowing for any final floor finishes, tiles etc.
b. Check and ensure that the horizontal top and side edges are level and that the front
vertical edges are plumb.
c. Use plastic packers under the feet or directly under the trough on UESI urinals to make
level or raise the urinal to the correct height. Do not use metal packers.
Once satisfied that the urinal is level, a container of water can be poured into the urinal
gutter to ensure that it adequately drains to the waste outlet.
4. Take note and mark any applicable reference points, then, remove the urinal from the set
position.
5. Mix a mortar or non-shrink grout slurry to a soft malleable consistency. The slurry mixture
should hold firm in a mound yet be pliable enough to spread throughout the underside
cavity of floor mounted urinals. For recessed urinals the slurry will be contained within the
trench cavity and can be of a softer consistency allowing it to overflow when the urinal is
placed into position.
6. Place the urinal back into position ensuring any packers used within the dry run are
correctly arranged and remain in location and that the waste outlet spigot is seated within
the discharge pipe.
a. It is critical to ensure that the slurry has not raised the base of the gutter or the formation
of the outlet that will prevent adequate draining.
b. Bed the urinal down to ensure it is seated correctly by applying even pressure to the
urinal. Even pressure can be applied to the urinals gutter, by standing on a length of timber
placed into the trough. Placing your foot on the outlet cover and applying pressure will also
ensure the outlet is correctly seated.
c. The urinal must be fully supported to alleviate any flexing. No air pockets should be
present.
d. Weighted timbers can be placed within the trough to maintain the formation of the
trough.
4
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023

Australia’s Finest Stainless | britex.com.au 5
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023
Installation Instructions
7. Recheck all levels and drainage capability (refer back to step 3 procedures) and make
any final adjustments as necessary.
8. Once satisfied that the urinal is perfectly level and the gutter base and outlet sufficiently
drain, drill through the tiled edge at the back and sides of the urinal and insert appropriate
fixings into studs or noggins at no less than 600mm (23.6”) centres.
9. Remove and dispose the overflow of excess slurry and clean away any spillage from the
surface of the urinal with a damp cloth, taking care not to scratch any exposed stainless
steel.
10. Complete the connection of the flushing device to the urinal. The flushing device should
then be tested and all connections checked for leaks.
11. Perform a flush cycle to condition the weir sparge, followed by a second cycle to ensure
that an adequate volume of water is being delivered to sufficiently flush the entire urinal
face. Make any applicable adjustments to the volume of water, pressure or flow rates as
necessary. Refer to the manufacturer’s installation and operation manuals for any flushing
devises to be coupled with the urinal.
12. On the completion of commissioning the urinal, and all associated plumbing and
fixtures, the wall and floor coverings can now be completed. The perimeter of the urinal
should then be sealed with an appropriate non-pickable sealer.
13. Protect the urinal and do not remove the protective PVC coating while additional
building works are being conducted. On completion of all building works and prior to
functional use, the PVC coating should be removed and the urinal cleaned as per the
following cleaning and general maintenance instructions.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORISED SERVICE PERSON
UESI-LF
Water Saving Urinal
A3
SHEET 2 OF 3
SCALE:1:10
TITLE:
DO NOT SCALE DRAWING
DATE
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
APPV'D
CHK'D
DRAWN
REVISION
Britex Metal Products Co. Pty Ltd.
ACN: 004 309 737
2 Mirra Ct, Bundoora Victoria 3083
P: 03 9466 9000 F: 03 9466 9044
britex.com.au [email protected]
Drawing:
AW
24/02/23
A
SD-2609.2
UESI-LF
Water Saving Urinal
A3
SHEET 3 OF 3
SCALE:1:10
TITLE:
DO NOT SCALE DRAWING
DATE
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
APPV'D
CHK'D
DRAWN
REVISION
Britex Metal Products Co. Pty Ltd.
ACN: 004 309 737
2 Mirra Ct, Bundoora Victoria 3083
P: 03 9466 9000 F: 03 9466 9044
britex.com.au [email protected]
Drawing:
AW
24/02/23
A
SD-2609.3
Installation of this unit must be in accordance with The Plumbing Code of Australia (PCA), AS/NZ
3500.1 & AS/NZ 3500.2. For further support and after-sales care, please contact Britex.

Australia’s Finest Stainless | britex.com.au
6
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023
Care and Maintenance
Cleaning: The coil at the front of the unit
and the vents on the side must be kept clean
from dust and lint. Regular checks of the
unit should be conducted on a weekly basis
and cleaning carried out as necessary by
dusting with a soft brush and/or vacuuming.
A damp cloth can be used to wipe the
exterior cover down. Excessive build up of
foreign material will result in poor ventilation,
causing the compressor to overheat and
drinking water to increase in temperature.
High pressure hoses and water jets should
never be used to clean chiller units.
Stainless steel products should be kept
clean at all times. The secret to stainless
steel’s ability to maintain a high quality
finish and promises of a long life expectancy
is the invisible chromium-oxide film that
sits on the surface and protects the steel
beneath. To maintain this film it is essential
that the surface remains clean and in
constant contact with oxygen. If this film is
penetrated (either by abrasion or chemically)
and dirt, liquid, grime contaminants embed
themselves in these micro chasms for an
extended period of time, the chromiumoxide
film will not be able to regenerate
and the steel below will eventually
become damaged and discoloured.
What we recommend for general cleaning
and maintenance:
Cleaning Materials:
• A soft cloth
• A soft-bristled brush
• A natural or artificial sponge
Cleaning Solutions:
• Hand washing soap / soft water solution
• Mild soap / soft water solution
• White vinegar / soft water solution
It is recommended that general cleaning
of stainless steel surfaces be carried
out weekly, or as soon as a build up of
surface media has been observed. To
clean, simply wash stainless steel surfaces
with, warm, diluted, mild soapy water
using a cloth or soft bristled brush. Once
all dirt, oil and grime is removed, rinse
thoroughly with clean water and wipe dry.
Do NOT – use a metal brush or steel wool
to clean stainless steel. Ever. These tools
will scratch the surface as well as potentially
leave behind steel fragments that can go
rusty and cause the stainless to discolour.
Using these materials will void the warranty.
Do NOT – use scourers of any kind
that have previously been used on
ordinary steel. Microscopic steel fibers
transferred onto stainless steel can
cause considerable damage to the
surface and will void the warranty.
Do NOT – use abrasive cleaning brushes,
pads or agents on highly polished finishes
Do NOT use harsh cleaners that contain
powerful acidic or alkaline chemicals such
as hydrochloric acid and sodium hydroxide
that will damage the surface. Any water
coming into contact with stainless steel,
particularly cleaning solutions, should
have zero chloride content as even minute
amounts can cause damage. Using these
cleaners will void any product warranty.
Do NOT – use chlorinated sanitizers,
cleansers or bleach of any kind. Using these
substances will void the warranty. Despite
some cleaners displaying the text, ‘Suitable
for Toilets and Urinals’ this is more likely in
reference to ceramic/vitreous China products
and use of these cleaners can damage
stainless steel and will void the warranty.
Do NOT – use brick cleaning liquids that contain
hydrochloric acid anywhere near stainless. If
cement needs to be removed from stainless
(before it sets), a mixture of hot water and
25% vinegar or 10% phosphoric acid can be
effective. Once cleaned, the surface should
then be neutralised with dilute ammonia or
sodium bicarbonate then rinsed and dried

Australia’s Finest Stainless | britex.com.au 7
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023
Warranty
The BRITEX product is backed by our manufacturer’s warranty available for download
from our website at www.britex.com.au. We expressly warrant that the product is free from
operational defects in workmanship and materials for the warranty period indicated on the
schedule in the manufacturer’s warranty. During the warranty period, BRITEX will repair or
replace any defective products manufactured by BRITEX at no charge, provided that the
terms of the manufacturer’s warranty are followed.
This warranty is the only warranty given by BRITEX, and we expressly disclaim all other
warranties, including but not limited to implied warranties of merchantability and fitness
for a particular purpose. This warranty represents the sole and exclusive remedy for breach
of warranty, and BRITEX shall not be liable for any incidental, special, or consequential
damages, including lost profits, labor charges, delays, vandalism, negligence, fouling
caused by foreign material, damage from adverse water conditions, chemical, electrical or
any other circumstances beyond BRITEX’s control.
This warranty shall be void if the product is abused, misused, improperly installed,
maintained, or altered. By purchasing our product, you agree to these terms and
conditions. We appreciate your business and look forward to providing you with high-
quality products and services.
Spare Parts
FSM1
Smart Saniflush Sensor System
72-05-0016
Complete Waste Assembly (Diaphragm, Boss & Dome)
74-05-0029
Y Strainer DIN15 1/2” BSP Thread CF8M G316 (Watermarked)
74-05-0017
Strainer Brass Y Shape 1/2” F x 1/2” F (Watermarked)

MELBOURNE
Britex Place Mirra Crt
Bundoora VIC 3083
t(03) 9466 9000
e[email protected]om.au
SYDNEY
16 Northumberland Drv
Taren Point NSW 2229
t(02) 9531 2100
ensw@britex.com.au
PERTH
Unit 1/8 Principal Link
Malaga WA 6090
t(08) 9249 5464
ewa@britex.com.au
BRISBANE
19 Manilla St
East Brisbane QLD 4169
t(07) 3363 2400
e[email protected]om.au
ADELAIDE
The Britex Group
SA State Office
t1300 764 744
e[email protected]om.au
UESI-LF Installation Guide | QID 1.11 | Rev 3 | 9 Mar 2023
Table of contents
Other Britex Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Stealth Products
Stealth Products TFB owner's manual

Hama
Hama 00125121 operating instructions

New Star Computer Products
New Star Computer Products FPMA-LIFT100 instruction manual

Hills
Hills EZY HD 600mm GUTTER MOUNT installation instructions

ergolutions
ergolutions 10001 manual

NCR
NCR SelfServ Checkout 7350 Kit instructions