GUIDE SPECIFICATIONS
Gas Furnace
58CVA/CVX
General
SYSTEM DESCRIPTION
Furnish a _________________ Variable speed gas-fired
furnace for use with natural gas or propane (factory
authorized conversion kit required for propane); furnish
cold air return plenum; furnish external medial cabinet for
use with accessory media filter or standard filter.
QUALITY ASSURANCE
Unit will be designed, tested and constructed to the
current ANSI Z 21.47/CSA 2.3 design standard for
gas-fired central furnaces. Unit will be 3rd party certified
by CSA to the current ANSI Z 21.47/CSA 2.3 design
standard for gas-fired central furnaces.
Unit will carry the CSA Blue StarRand Blue FlameR
labels.
Unit efficiency testing will be performed per the current
DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and
listed in the latest GAMA Consumer’s Directory of
Certified Efficiency Ratings.
Unit shall carry the current Federal Trade Commission
Energy Guide efficiency label.
DELIVERY, STORAGE AND HANDLING
Unit shall be shipped as single package only and is
stored and handled per unit manufacturer’s
recommendations.
WARRANTY (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available
upon request.
Products
EQUIPMENT
Components shall include: slow-opening two-stage dual
fuel gas valve to reduce ignition noise, regulate gas flow,
with electric switch gas shut-off; flame proving sensor, hot
surface igniter, dual pressure switch assembly, flame
rollout switch, ICM blower and two speed inducer
assembly, 40va transformer; low-voltage (heating)
(heating/cooling) thermostat.
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type,
statically and dynamically balanced. Blower motor of
variable speed ECM type shall be permanently lubricated
with sealed ball bearings, of _______hp, and supplies
delivers requested airflow CFM as defined by signals
received from EZ-SELECT airflow control when 24V
motor inputs are provided. Blower motor shall be direct
drive and soft mounted to the blower scroll to reduce
variation transmission.
Filters
Furnace may have reusable-type filters. Filter shall be
_______ in. (mm) (x) _______in. (mm) An accessory high
efficiency Media Filter is available as an option.
_______________ Media Filter.
Casing
Casing shall be of .030 in. (.76 mm) thickness
minimum, pre-painted galvanized steel.
Two Speed Inducer Motor
Two Speed Inducer motor shall be soft mounted to
reduce vibration transmission.
Flame Rollout Switch
Flame Rollout Switch shall be factory installed near
burner area to further reduce the possibility of a stuck gas
valve or failed inducer motor.
Heat Exchangers
Heat exchangers shall be a 4-Pass 20 gage corrosion
resistant aluminized steel of fold--and--crimp sectional
design when applied operating under negative pressure.
Controls
Control shall include a micro-processor based
integrated electronic control board with at least 11 service
troubleshooting codes displayed via diagnostic flashing
LED light on the control, a self-test feature that checks all
major functions of the furnace within one minute, and a
replaceable automotive-type circuit protection fuse.
Multiple operational settings available with the
EZ-SELECT fan control, including, separate blower
speeds for low heat, high heat, low cooling, high cooling
and continuous fan. Continuous fan speed may be adjusted
from the thermostat. Cooling airflow will be selectable
between 350 or 400 CFM per ton of air conditioning.
Features will also include temporary reduced airflow in the
cooling mode for improved dehumidification when an
InfinitytControl or Thermidistattis selected as the
thermostat.
OPERATING CHARACTERISTICS
Heating Capacity shall be ________ Btuh input;
________ Btuh output capacity.
Fuel Gas Efficiency shall be 80% AFUE.
Air delivery shall be ___________ cfm minimum at
0.50 in. wc external static pressure.
Dimensions shall be: depth __________ in. (mm);
width _________ in; height_________in. (mm) (casing
only). Height shall be_________in. (mm) with A/C coil
and _____________in. (mm) overall with plenum.
ELECTRICAL REQUIREMENTS
Electrical supply shall be 115 volts, 60 Hz,
single--phase (nominal). Minimum wire size shall
be_________AWG; maximum fuse size or circuit breaker
shall be __________Amps.
SPECIAL FEATURES
Refer to section of the product data sheet identifying
accessories and descriptions for specific features and
available enhancements.
Copyright 2009 Carrier Corp. D7310 W. Morris St. DIndianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/09
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: 58CV---5PD
Replaces: 58CV--- 4PD
58CVA/CVX