CICOGNANI ENGINEERING 5018 User manual

5018
Class D Guitar Power Amplifier
USER MANUAL
(UK)
CICOGNANI ENGINEERING
Via Faentina,44 - 48013 - Brisighella (RA) Italy
P.iva: 01277580393

WARRANTY TERMS
The guarantee of CICOGNANI ENGINEERING products is two
years from the purchase data except for the parts subject to wear
and tear from the switches, buttons, relays that is one year. The
thermionic valves, indicator lights, wiring cables are guaranteed
for three months. Security is not a problem, but it's just a way of
thinking, managing things to do and not thinking about presented
to the carrier); damage from incorrect connections, with non-
conforming modifications (altered / modified), with interfacing to
malfunctioning devices.
The responsibility of CICOGNANI ENGINEERING is limited to
repairing the product or replacing it. (Replacement at our choice)
CICOGNANI ENGINEERING will not be liable for damages
resulting from failure to use the product, interrupted operation,
commercial, incidental, consequential, transport or unsuitable
packaging.
How to receive assistance: Send an email request to
where to send the product. The product must be sent together
with a copy of the receipt / sales receipt together with which a
description of the claimed fault is appreciated. I recommend to
make a packaging suitable to well protect the product not
including manuals, cables, effects or various accessories. The
costs of labor and material under warranty will be charged to the
CICOGNANI ENGINEERING.
Shipping and packing costs are the responsibility of the
purchaser.
THE WARRANTY HAS VALIDITY IF THE PRODUCT IS A COPY
OF THE RECEIPT OF SALE IN A WAY THAT ATTEND THE
DATE OF PURCHASE
USEFUL INFORMATION
5018 is a class D amplifier with a final stage that offers a
maximum power of 60W RMS on impedance of 4Ohm. Small,
light, compact, it integrates a pre-amplifier in JFET technology.
The reasons that led me to use this formula are focused on the
musicality of the product and the great feeling of similar use in the
response to the most famous tube amplifiers.
THE PRE-AMPLIFIER in "cascode" technique proposes an
amazing linearity of signal useful to guarantee great benefits of
interfacing and transparency of the signal to other units.
TONE CONTROL includes three passive filters that act on the
frequencies: 80Hz (low); 560Hz (middle); 5500Hz high.
EFFECT LOOP is “serial” with output buffer in order to allow a
better adaptation result towards external units. This makes it
possible to connect analog, digital and hybrid effects device to
your liking.
POWER STAGE employs a class D digital module with PBTL
configuration. Although the connection of a speaker with an
impedance of 4 to 16Ohm is possible. The best performance of
power and linearity can be identified in 4 and 8Ohm.
CAUTION!! the bridge ending provides exclusively direct
connection to the cashier (NO NEGATIVE SPEAKER TO GND)
ALL AUDIO CONNECTIONS ARE OF A SINGLE 6.3mm JACK
TYPE.
The Guru advises:
Use a "speaker" cable to connect loudspeaker with a minimum
cross-section of 2X1mm. up to 5 meters.
The recommended power supply to guarantee the correct
performance is with 24Vdc voltage (central positive) with 3
Ampere working current.
5018 is a guitar amplifier not a pedal effect: be very careful to
connect the "SPEAKER" output only and exclusively to a
speaker. Never connect the "SPEAKER" output to an input of
another amplifier, pedal effect, mixer, computer, or similar units.

TECHNICAL FEATURES
POWER IN 12 TO 24VDC(POSITIVE TIP)
CONSUMPTION MAX 3A TO 24VDC
INPUT IMPEDENCE < 1 M Ohm
INPUT LEVEL MAX 500mV
SEND IMPEDANCE < 100 K Ohm
SEND LEVEL < 250mVpp
RETURN IMPEDANCE < 100 K Ohm
RETURN LEVEL < 500mVpp
BASS FREQUENCY 80 Hz
MIDDLE FREQUENCY 560 Hz
TREBLE FREQUENCY 5500 Hz
MAX S/N RATIO 55db
MAX POWER OUT 60Wrms to 4 Ohm
IMPEDANCE OUT 4/8/16 Ohm (BST performance to 4/8 Ohm)
WEIGHT 0,3 Kg. (0,6 lib.)
WIDTH 94 mm. (3,7 in.)
LENGHT 120 mm. (4,7 in.)
HEIGHT (MAX) 45 mm. (1,770 in.)
EXTERNAL MUTE FOOTSWITCH ON/OFF STABLE
FCC RULES
This equipment has been tested and found to comply with the
limits for a Class D digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does not
cause harmful interference to radio or television reception, you are
encouraged to try to correct the interference by one or more of the
following measures:
1) Re-orient or transfer the receiving antenna.
2) Increase the separation between the equipment and the
receiver.
3) Connect the equipment into an outlet on a circuit different from
that.
4) Consult the dealer or an experienced radio / TV technician.
Modifications not expressly approved by the manufacturer could
void the user's authority to operate the equipment in accordance
with FCC rules.
CICOGNANI ENGINEERING reserves the right to modify the
technical characteristics and layout of the products at any
time and without notice. This product is built to the rule of art
and observes the technical requirements of t h e
DirectivesEuropee 89/366EEC

TECHNICAL DIAGRAM
EXTERNAL MUTE EXEMPLE CONNECTION
STANDARD CAB/ AMPLIFIER EXEMPLE CONNECTION
CAB/AMPLIFIER + STACK EXEMPLE CONNECTION
CONNECTIONS
Table of contents
Popular Amplifier manuals by other brands

PRESONUS
PRESONUS FIRESTUDIO MOBILE - SCHEMA Connection instruction

MICROWAVE SYSTEMS
MICROWAVE SYSTEMS MS061805 Operation manual

Academy Dragster
Academy Dragster DA-4860DSP user manual

Cerwin-Vega
Cerwin-Vega CUPM Series manual

McIntosh
McIntosh A116 - SCHEMATICS manual

Alto Professional
Alto Professional APX2000 quick start guide