Circutor CBS-2000AB User manual

INSTRUCTION MANUAL
Multi-channel earth leakage current monitor
CBS-2000AB, CBS-1600A
(M340B01-03-22A)

2
CBS-2000AB, CBS-1600A
Instruction Manual

3
Instruction Manual
CBS-2000AB, CBS-1600A
SAFETY PRECAUTIONS
DANGER
Warns of a risk, which could result in personal injury or material damage.
ATTENTION
Indicates that special attention should be paid to a specific point.
Follow the warnings described in this manual with the symbols shown below.
If you must handle the unit for its installation, start-up or maintenance, the following should be
taken into consideration:
Incorrect handling or installation of the device may result in injury to personnel as well as damage to
the device. In particular, handling with voltages applied may result in electric shock, which may cause
death or serious injury to personnel. Defective installation or maintenance may also lead to the risk of
fire.
Read the manual carefully prior to connecting the device. Follow all installation and maintenance in-
structions throughout the device’s working life. Pay special attention to the installation standards of
the National Electrical Code.
Refer to the instruction manual before using the device
In this manual, if the instructions marked with this symbol are not respected or carried out correctly, it can result
in injury or damage to the device and/or installations.
CIRCUTOR S.A.U. reserves the right to modify features or the product manual without prior notification.
DISCLAIMER
CIRCUTOR S.A.U. reserves the right to make modifications to the device or the unit specifications set
out in this instruction manual without prior notice.
CIRCUTOR S.A.U. on its web site, supplies its customers with the latest versions of the device specifi-
cations and the most updated manuals.
www.circutor.com
CIRCUTOR S.A.U. recommends using the original cables and accessories that are sup-
plied with the device.

4
CBS-2000AB, CBS-1600A
Instruction Manual
CONTENTS
SAFETY PRECAUTIONS .........................................................................................................................................................3
DISCLAIMER ..........................................................................................................................................................................3
CONTENTS.............................................................................................................................................................................4
REVISION LOG .......................................................................................................................................................................6
SYMBOLS...............................................................................................................................................................................6
1. VERIFICATION UPON RECEPTION.................................................................................................................................... 7
2 PRODUCT DESCRIPTION .................................................................................................................................................7
3. INSTALLATION OF THE DEVICE .......................................................................................................................................9
3.1.- PRELIMINARY RECOMMENDATIONS ........................................................................................................................9
3.2.- INSTALLATION ....................................................................................................................................................... 10
3.3.- DEVICE TERMINALS............................................................................................................................................... 10
3.3.1. CBS-1600A........................................................................................................................................................ 10
3.3.2. CBS-2000AB .....................................................................................................................................................11
3.4.- WGB AND WGC TRANSFORMERS........................................................................................................................... 12
3.4.1. PANEL INSTALLATION ...................................................................................................................................... 12
3.4.2. DIN RAIL INSTALLATION OF WGB TRANSFORMERS ......................................................................................... 13
3.4.3. DIN RAIL INSTALLATION OF WGC TRANSFORMERS ......................................................................................... 15
3.4.4. TRANSFORMER TERMINALS ............................................................................................................................. 16
3.4.5. TRANSFORMER LEDs........................................................................................................................................ 16
3.5.- CONNECTION DIAGRAMS....................................................................................................................................... 17
3.5.1. CBS-1600A........................................................................................................................................................ 17
3.5.2. CBS-2000AB .................................................................................................................................................... 18
3.6.- INSTALLATION CONNECTIONS................................................................................................................................ 19
3.6.1. CBS-1600A........................................................................................................................................................ 19
3.6.2. CBS-2000AB .................................................................................................................................................... 19
4. OPERATION ...................................................................................................................................................................20
4.1.- LED INDICATORS ....................................................................................................................................................20
4.2.- DISPLAY ................................................................................................................................................................. 21
4.3.- KEYBOARD FUNCTIONS.........................................................................................................................................22
4.4.- RELAYS ..................................................................................................................................................................22
4.5.- DIGITAL INPUT.......................................................................................................................................................22
5. DISPLAY.........................................................................................................................................................................23
5.1.- PROBLEMS OR CHANGES IN THE INSTALLATION (Model CBS-2000AB) ..............................................................23
5.2.- DISPLAY SCREENS.................................................................................................................................................24
5.3.- TRIP DISPLAY SCREENS.........................................................................................................................................25
5.3.1.- TYPE B CHANNELS ..........................................................................................................................................26
5.3.2.- TYPE A CHANNELS..........................................................................................................................................26
5.3.3.- EXTERNAL TRIP, COMMUNICATIONS TRIP.......................................................................................................27
5.4.- TEST SCREEN ........................................................................................................................................................27
5.5 .- DIRECT SETTINGS ................................................................................................................................................28
5.5.1.- TRIP CURRENT ................................................................................................................................................28
5.5.2.- DELAY AND RELAY CURVE .............................................................................................................................28
5.6.- EVENT MENU.........................................................................................................................................................29
5.7.- LOCK ...................................................................................................................................................................... 31
5.8.- ERROR SCREEN ..................................................................................................................................................... 31
6. CONFIGURATION ...........................................................................................................................................................32
6.1.- RS-485 COMMUNICATIONS ...................................................................................................................................33
6.1.1.- BAUD RATE......................................................................................................................................................33
6.1.2.- PERIPHERAL NUMBER....................................................................................................................................33
6.1.3.- DATA FORMAT .................................................................................................................................................34
6.2.- CLOCK SETUP MENU .............................................................................................................................................35
6.3.-GLOBAL SETTINGS .................................................................................................................................................36
6.3.1.- TRIP CURRENT .............................................................................................................................................36
6.3.2.- DELAY..............................................................................................................................................................37
6.4.- PREALARM ............................................................................................................................................................37
6.4.1.- PREALARM CHANNEL.....................................................................................................................................38
6.4.2.- PREALARM CURRENT OF CHANNEL x...........................................................................................................38
6.4.3.- OPERATION OF CHANNEL x’S PREALARM .....................................................................................................39
6.5.- CHANNELS.............................................................................................................................................................39

5
Instruction Manual
CBS-2000AB, CBS-1600A
6.5.1.- CHANNEL SWITCHING.................................................................................................................................... 40
6.6.- INSTALLATION....................................................................................................................................................... 40
6.6.1.- SAVE INSTALLATION ...................................................................................................................................... 40
7. RS485 COMMUNICATIONS...........................................................................................................................................42
7.1.- CONNECTIONS ........................................................................................................................................................42
7.2.- MODBUS PROTOCOL ..............................................................................................................................................42
7.3.- MODBUS COMMANDS............................................................................................................................................43
7.3.1.-DEVICE AND INSTALLATION PARAMETERS ......................................................................................................43
7.3.2.- PARAMETERS OF THE TYPE B CHANNELS .....................................................................................................44
7.3.3.- PARAMETERS OF THE TYPE A CHANNELS .....................................................................................................46
7.3.4.- TRIP BY TEST OR COMMUNICATIONS OF TYPE B CHANNELS..........................................................................48
7.3.5.- TRIP BY TEST OR COMMUNICATIONS OF TYPE A CHANNELS .........................................................................48
7.3.6.- EVENTS............................................................................................................................................................49
7.3.7.- DEVICE CONFIGURATION PARAMETERS ........................................................................................................ 50
8. TECHNICAL FEATURES..................................................................................................................................................53
8.1.- CBS-1600A ............................................................................................................................................................53
8.2.- CBS-2000AB.........................................................................................................................................................55
8.3.- WGB.......................................................................................................................................................................57
8.4.- WGC.......................................................................................................................................................................59
9. MAINTENANCE AND TECHNICAL SERVICE ...................................................................................................................63
10. GUARANTEE ................................................................................................................................................................63
11. EU DECLARATION OF CONFORMITY ............................................................................................................................64
ANNEX A. DIRECT SETTINGS.............................................................................................................................................67
ANNEX B. CONFIGURATION MENU................................................................................................................................... 68

6
CBS-2000AB, CBS-1600A
Instruction Manual
REVISION LOG
Table 1: Revision log.
Date Revision Description
03/22 M340B01-03-22A First Version
Note: The images of the devices are for illustrative purposes only and may differ from the original
device.
SYMBOLS
Table 2: Symbols.
Symbol Description
In accordance with the relevant European directive.
Device covered by European Directive 2012/19/EC. At the end of its useful life, do not discard of
the device in a household refuse bin. Follow local regulations on electronic equipment recycling.
Direct current.
~Alternating current.

7
Instruction Manual
CBS-2000AB, CBS-1600A
1. VERIFICATION UPON RECEPTION
Upon reception of the device check the following points:
a) The device meets the specifications described in your order.
b) The device has not suffered any damage during transport.
c) Perform an external visual inspection of the device prior to switching it on.
d) Check that it has been delivered with the following:
- An installation guide
If any problem is noticed upon reception, immediately contact the transport com-
pany and/or CIRCUTOR's after-sales service.
2 PRODUCT DESCRIPTION
The CBS-2000AB is a hybrid earth leakage current monitoring device that can be used to connect up
to 16 type-A channels via transformers in the WGC range, and 4 type-B channels using transformers
in the WGB range.
The CBS-1600A model is a type A earth leakage current monitoring device with up to 16 measurement
channels using transformers in the WGC range.
The device features:
-Display for viewing the parameters.
- 3 keys to browse through the different screens and program the device.
-2 relays: an alarm relay and a pre-alarm relay.
- Digital input for external trip.
- RS-485 communications.
The WGB are a range of electronic, type-B earth leakage protection and monitoring transformers (IEC
60755).
Circutor has 4 models, depending on the maximum current of the monitored circuit (In):
WGB-35, for In: 80 A.
WGB-55 for In: 160 A.

8
CBS-2000AB, CBS-1600A
Instruction Manual
WGB-80 for In: 250 A.
WGB-110 forIn: 400 A.
The transformers have:
- 6 LEDs providing information about the transformer's status.
- 2 RJ45 connection and power supply ports.
The WGC is a range of electronic, type A earth leakage protection and monitoring transformers (IEC
60044-1).
CIRCUTOR offers 14 models, depending on the size of the transformer.

9
Instruction Manual
CBS-2000AB, CBS-1600A
3. INSTALLATION OF THE DEVICE
3.1.- PRELIMINARY RECOMMENDATIONS
In order to use the device safely, personnel operating it must follow the safety meas-
ures that comply with the standards of the country where it is to be installed; operators
must wear the required personal protective equipment (rubber gloves, approved facial
protection and flame-resistant clothing) to prevent injuries from electric shock or arcs
caused by exposure to current-carrying conductors, and they must heed the various
warnings indicated in this instruction manual.
The CBS-2000AB/CBS-1600A device must be installed by authorised and qualified staff.
The power supply plug must be disconnected and measurement systems switched off before handling,
altering the connections or replacing the device. It is dangerous to handle the device while it is pow-
ered.
Cables must always be kept in perfect condition to avoid accidents or injury to personnel or installa-
tions.
Restrict the operation of the device to the specified measurement category, voltage or current values.
The manufacturer of the device is not responsible for any damage resulting from failure by the user
or installer to heed the warnings and/or recommendations set out in this manual, nor for damage
resulting from the use of non-original products or accessories or those made by other manufacturers.
Do not use the device to take any measurements if an anomaly or malfunction is detected.
Check the surrounding environment before starting to take measurements. Do not take any measure-
ments in hazardous or explosive environments.
Before carrying out maintenance, repair or handling of any of the device's connections,
the device must be disconnected from all power sources, both from the device's own
power supply and the measurement's.
Contact the after-sales service if you detect that the device is not working properly.

10
CBS-2000AB, CBS-1600A
Instruction Manual
3.2.- INSTALLATION
When the device is on, its terminals, opening covers or removing elements may ex-
pose the user to parts that are hazardous to touch. Do not use the device until it is
fully installed.
The device must be installed inside a medium or low voltage electric panel or enclosure, with DIN rail
mounting (IEC 60715).
The device has a LED (CPU) that indicates voltage presence. Even in the case that the
aforesaid LED is off, the user still needs to check the device is disconnected from any
power supply.
The device must be connected to a power circuit protected by a fuse according to its power and con-
sumption rating. It must be fitted with a circuit breaker or equivalent device to disconnect the device
from the power supply.
3.3.- DEVICE TERMINALS
3.3.1. CBS-1600A
A1
A2
25
26
27
28
29
30
18
17
16
15
14
13
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
48
47
46
45
Central Módulo/Module CentralMódulo/Module
Figure 1: Terminals of the CBS-1600A: Upper- Lower.
Table 3: List of terminals on the CBS-1600A (Central).
Device terminals: Central
A1: A1, Power supply 29: R2, Prealarm relay (NC)
A2: A2, Power supply 30: C2, Common prealarm relay
25: R1, Alarm relay (NO) 45: TRIP, Digital input for external trigger
26: R1, Alarm relay (NC) 46: GND for RS-485 and Digital input TRIP
27: C1, Common alarm relay 47: B-,RS-485
28: R2, Prealarm relay (NO) 48: A+, RS-485

11
Instruction Manual
CBS-2000AB, CBS-1600A
Table 4: List of terminals on the CBS-1600A (Module).
Device terminals: Module
1: CH11, 1S1 WGC input Channel 1.1 13: CH21, 1S1 WGC input Channel 2.1
2: CH11 - CH12, 1S2 WGC input Channel 1.1 and 1.2 14: CH21 - CH22, 1S2 WGC input Channel 2.1 and 2.2
3: CH12, 1S1 WGC input Channel 1.2 15: CH22, 1S1 WGC input Channel 2.2
4: CH13, 1S1 WGC input Channel 1.3 16: CH23, 1S1 WGC input Channel 2.3
5: CH13 - CH14, 1S2 WGC input Channel 1.3 and 1.4 17: CH23 - CH24, 1S2 WGC input Channel 2.3 and 2.4
6: CH14, 1S1 WGC input Channel 1.4 18: CH24, 1S1 WGC input Channel 2.4
7: CH15, 1S1 WGC input Channel 1.5 19: CH25, 1S1 WGC input Channel 2.5
8: CH15 - CH16, 1S2 WGC input Channel 1.5 and 1.6 20: CH25 - CH26, 1S2 WGC input Channel 2.5 and 2.6
9: CH16, 1S1 WGC input Channel 1.6 21: CH26, 1S1 WGC input Channel 2.6
10: CH17, 1S1 WGC input Channel 1.7 22: CH27, 1S1 WGC input Channel 2.7
11: CH17 - CH18, 1S2 WGC input Channel 1.7 and 1.8 23: CH27 - CH28, 1S2 WGC input Channel 2.7 and 2.8
12: CH18, 1S1 WGC input Channel 18 24: CH28, 1S1 WGC input Channel 2.8
3.3.2. CBS-2000AB
A1
A2
25
26
27
28
29
18
17
16
15
14
13
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
48
47
46
45
30
WGB
Central Módulo/Module CentralMódulo/Module
Figure 2: Terminals of the CBS-2000AB: Upper- Lower.
Table 5: List of terminals on the CBS-2000AB (Central).
Device terminals: Central
A1: A1, Power supply 30: C2, Common prealarm relay
A2: A2, Power supply 45: TRIP, Digital input for external trigger
25: R1, Alarm relay (NO) 46: GND for RS-485 and Digital input TRIP
26: R1, Alarm relay (NC) 47: B-,RS-485
27: C1, Common alarm relay 48: A+, RS-485
28: R2, Prealarm relay (NO) WGB: WGB transformer connection
29: R2, Prealarm relay (NC)

12
CBS-2000AB, CBS-1600A
Instruction Manual
Table 6: List of terminals on the CBS-2000AB (Module).
Device terminals: Module
1: CH11, 1S1 WGC input Channel 1.1 13: CH21, 1S1 WGC input Channel 2.1
2: CH11 - CH12, 1S2 WGC input Channel 1.1 and 1.2 14: CH21 - CH22, 1S2 WGC input Channel 2.1 and 2.2
3: CH12, 1S1 WGC input Channel 1.2 15: CH22, 1S1 WGC input Channel 2.2
4: CH13, 1S1 WGC input Channel 1.3 16: CH23, 1S1 WGC input Channel 2.3
5: CH13 - CH14, 1S2 WGC input Channel 1.3 and 1.4 17: CH23 - CH24, 1S2 WGC input Channel 2.3 and 2.4
6: CH14, 1S1 WGC input Channel 1.4 18: CH24, 1S1 WGC input Channel 2.4
7: CH15, 1S1 WGC input Channel 1.5 19: CH25, 1S1 WGC input Channel 2.5
8: CH15 - CH16, 1S2 WGC input Channel 1.5 and 1.6 20: CH25 - CH26, 1S2 WGC input Channel 2.5 and 2.6
9: CH16, 1S1 WGC input Channel 1.6 21: CH26, 1S1 WGC input Channel 2.6
10: CH17, 1S1 WGC input Channel 1.7 22: CH27, 1S1 WGC input Channel 2.7
11: CH17 - CH18, 1S2 WGC input Channel 1.7 and 1.8 23: CH27 - CH28, 1S2 WGC input Channel 2.7 and 2.8
12: CH18, 1S1 WGC input Channel 1.8 24: CH28, 1S1 WGC input Channel 2.8
3.4.- WGB AND WGC TRANSFORMERS
When the device is on, its terminals, opening covers or removing elements may ex-
pose the user to parts that are hazardous to touch. Do not use the device until it is
fully installed.
The transformer is designed for wall-mounting or DIN-rail assembly with an accessory for installation.
The WGB /WGC is a feed-thru busbar type transformer, where the conductor cables to be measured
must pass through the inner hole or window of the transformer.
3.4.1. PANEL INSTALLATION
For panel installation, 4 clamping clips, are provided with the transformer, see Figure 3.
Figure 3: Clamping clip.
The clamping clips which must be installed on the WGB/WGC as shown in Figure 4.

13
Instruction Manual
CBS-2000AB, CBS-1600A
Figure 4: Position of the clamping clips.
3.4.2. DIN RAIL INSTALLATION OF WGB TRANSFORMERS
For installation on a DIN rail, a support bracket is provided with the device, see Figure 5.
Figure 5: Support bracket.
The steps to ensure proper installation are:
1.- Attach the bracket to the DIN rail. Be sure the side marked FRONT is visible. The bracket can be in-
stalled in 2 ways, depending on how the WGB is to be positioned, Figure 6.
2.-Mount the WGB on the bracket, Figure 6.

14
CBS-2000AB, CBS-1600A
Instruction Manual
Figure 6: Installation on a DIN rail.
Note: To remove the bracket from the DIN rail, use a screwdriver to pry it off, Figure 7.
Figure 7: To remove the bracket use a screwdriver.

15
Instruction Manual
CBS-2000AB, CBS-1600A
3.4.3. DIN RAIL INSTALLATION OF WGC TRANSFORMERS
For installation on a DIN rail, two support brackets are provided with the device, see Figure 8.
Figure 8: WGC support brackets.
The steps to ensure proper installation are:
1.- Install the brackets in the WGC, Step 1 in Figure 9.
2.- Install the WGC on the DIN rail, Step 2 in Figure 9.
Step 1
Step 2
Figure 9: Installing a WGC on the DIN rail.

16
CBS-2000AB, CBS-1600A
Instruction Manual
3.4.4. TRANSFORMER TERMINALS
2
1
Figure 10: WGB terminals.
Table 7: List of WGB terminals
Device terminals
1, 2 Connection terminals to the CBS-2000AB and to the rest of WGB transformers.
3.4.5. TRANSFORMER LEDs
WGB transformers have 6 indicating LEDs.
Power Supply
TRIPChannel
Figure 11: WGB transformer LEDs.
- Power (Blue color), indicates that the device is supplied power.
- TRIP: (Red color), indicates that a leakage current trip has occurred.
(Red blinking), indicates that a prealarm has been generated.
- Channel (Green color), indicates the channel used for the WGB.
Table 8: Channel LEDs.
LEDs Description
Channel
Channel 1
Channel 2
Channel 3
Channel 4

17
Instruction Manual
CBS-2000AB, CBS-1600A
3.5.- CONNECTION DIAGRAMS
3.5.1. CBS-1600A
TRIP
45
46
Alimentación Auxiliar
Power Supply
A1
A2
~
~
A1
A2
1618
WGC
1S1
1S2
CH11
CH12
1S1 1S2 1S1 1S1 1S2 1S1
CH13 CH14 CH21
1S1 1S2 1S1 1S1
CH22 CH23
1S2 1S1
CH24
712 24
CH15
1S1 1S2 1S1 1S1
CH16 CH17
1S2 1S1
CH18
1S1 1S2 1S1 1S1 1S2 1S1
CH25CH26 CH27CH28
13
19
Figure 12: CBS-1600A connection diagram.

18
CBS-2000AB, CBS-1600A
Instruction Manual
3.5.2. CBS-2000AB
WGB
TRIP
45
46
Alimentación Auxiliar
Power Supply
A1
A2
~
~
A1
A2
WGB1
WGB2
WGB3
WGB4
16 18
WGC
1S1
1S2
CH11
CH12
1S1 1S2 1S1 1S1 1S2 1S1
CH13 CH14 CH21
1S1 1S2 1S1 1S1
CH22 CH23
1S2 1S1
CH24
7 12 24
CH15
1S1 1S2 1S1 1S1
CH16 CH17
1S2 1S1
CH18
1S1 1S2 1S1 1S1 1S2 1S1
CH25CH26 CH27CH28
13
19
Figure 13: CBS-2000AB connection diagram.

19
Instruction Manual
CBS-2000AB, CBS-1600A
3.6.- INSTALLATION CONNECTIONS
3.6.1. CBS-1600A
All active conductors that supply the loads or part of the installation where protection is required must
pass through the associated WGC transformers (2-wire connection).
3.6.2. CBS-2000AB
All active conductors that supply the loads or part of the installation where protection is required must
pass through the associated WGC (2-wire connection) or WGB (connection via RJ-45 cable) transform-
ers.
For each of the type-B channels to be monitored, connect the WGB transformer to the CBS-2000AB or
to the next transformer in the installation using the RJ-45 cable, Figure 14.
WGB WGB WGB WGB
CBS-2000AB
RJ45
Channel 1 Channel 2 Channel 3
Channel 4
Figure 14: CBS-2000AB - WGB connection.
Note: If a RJ45 connection cable other than the one supplied with the WGB is used, it must have a
cross-section of 4 x 2 x AWG24/7. The maximum distance from the CBS-2000AB to the furthest WGB
must be of 9 metres.
The CBS-2000AB detects the transformers automatically, assigning each of them a specific channel.
If the automatic channel connection carried out by the device does not match the installation carried
out in the output relays, the numbering of the channels in the CBS-2000AB can be changed without
modifying the installation (see "6.5 .- CHANNELS").
If the installation is modified and it involves new transformer, a replacement of the WGB ... the CBS-
2000AB will detect this change and light the screens in yellow, see “5.1.- PROBLEMS OR CHANGES IN THE
INSTALLATION (Model CBS-2000AB)”.

20
CBS-2000AB, CBS-1600A
Instruction Manual
4. OPERATION
4.1.- LED INDICATORS
The CBS-2000AB/CBS-1600A device has 2 LEDs:
- CPU, white color, indicates that the device is on.
- ALARM,
Table 9: ALARM LED.
LED Description
ALARM
Flashing red:
Indicates that a prealarm has been generated.
Red steady:
Indicates that one of the channels is tripped.
ALARM
CPU
ALARM
Figure 15: CBS-2000AB/CBS-1600A LED indicators.