CEP-81B, 101B, 121B
Installation and Operation Instruction Manual
19 www.coastair-ac.com
Operating
Instructions
Operation Instructions
Power button
Power switch on/off.
NOTE: The control is capable of displaying
temperature in degrees Fahrenheit or degrees
Celsius. To convert from one to the other, press
and hold the Up and Down buttons at the same
time for 3 seconds.
Mode button
Selects the appropriate operating mode. Each
time you press the button, a mode is selected
in a sequence that goes from AUTO, COOL,
DRY, FAN and HEAT (cooling only models
without).The mode indicator light illuminates
under the different mode settings.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing)
temperature settings in 1°F (or 2°F)
increments in a range of 62°F to 86°F (or 88°F) or
the TIMER setting in a range of 0~ 24hrs.
LED display
Shows the set temperature in °C or °F and the
Auto-timer settings. While on DRY and FAN
modes, it shows the room temperature.
Shows Error codes and protection code:
Note: When one of the above malfunctions occurs,
turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present,
turn off the unit and unplug the power cord. Contact
the manufacturer or its service agents or a similar
qualified person for service.
COOL operation
· Press the "MODE" button until the "COOL" indicator
light comes on.
· Press the ADJUST buttons "+" or "-" to select your
desired room temperature. The temperature can be set
within a range of 62°F~88°F(or 86°F).
· Press the "FAN SPEED" button to choose the fan speed.
HEAT operation(cooling only models without)
· Press the "MODE" button until the "HEAT" indicator
light comes on.
· Press the ADJUST buttons "+" or " - " to select your
desired room temperature. The temperature can be
set within a range of 62°F~88°F (or 86°F).
· Press the "FAN SPEED" button to choose the fan
speed.
Note: For some models, the fan speed can not be
adjusted under HEAT mode.
DRY operation
· Press the "MODE" button until the "DRY" indicator
light comes on.
· Under this mode, you cannot select a fan speed or
adjust the temperature. The fan motor operates at
LOW speed.
· Keep windows and doors closed for the best
dehumidifying effect.
· Do not put the duct to window.
AUTO operation
· When you set the air conditioner in AUTO mode, it
will automatically select cooling, heating(cooling only
models without), or fan only operation depending on
what temperature you have selected and the room
temperature.
· The air conditioner will control room temperature
automatically around the temperature point set by you.
· Under AUTO mode, you can not select the fan speed.
NOTE: Under AUTO mode, both the AUTO mode and
the actual operation mode indicator lights illuminate
for some models.
FAN operation
· Press the "MODE" button until the"FAN " indicator
light comes on.
· Press the "FAN SPEED" button to choose the fan
speed. The temperature can not be adjusted.
· Do not put the duct to window.
TIMER operation
· When the unit is on, pressing the Timer button
will initiate the Auto-off stop program, the TIMER
OFF indicator light illuminates. Press the UP or
DOWN button to select the desired time. Press
the TIMER button again within 5 seconds, the
Auto-on start program is initiated. And the
TIMER ON indicator
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some
models).
E4-Display panel communication error.
EC-Refrigerant leakage detection malfunction(on
some models).
E7-Zero-crossing malfunction.
P1-Bottom tray is full--Connect the drain hose and
drain the collected water away.If protection
repeats, call for service.