Compressed Air Alliance ACC000501 User manual

www.compressedairalliance.com 1
User Manual
Flow Meter Enclosure
Model: ACC000501

Flow Meter Enclosure User Manual v1.0
www.compressedairalliance.com 2
Notices
Please read this manual in full and
carefully observe the notes and
instructions before and during
installation, operation and maintenance.
The manufacturer cannot be held liable
for any damage which occurs as a result
of noncompliance with this manual.
Do not tamper with device. Should the
device be tampered with in any manner
other than a procedure which is
described and specified in this manual,
the warranty is cancelled and the
manufacturer is exempt from liability.
The product is designed exclusively
for the described application. Use of
this product in conditions not specified
in this manual or, contrary to the
instructions provided by the
manufacturer, is considered improper
handling of the product and will void
your warranty. The manufacturer will
not be held liable for any damages
resulting from improper use of the
product.
This manual should be read carefully by
relevant personnel and the end user.
This manual should be kept with the
product and be made available as
needed. Once you install or use the
product, you accept that you have
read, understood and complied with
this manual.
Compressed Air Alliance endeavours to
make the content of this manual correct,
but is not responsible for omissions or
errors and the consequences caused. In
case of any doubts or questions
regarding this manual or the product,
please contact Compressed Air Alliance.
Warnings
Ignoring the warnings can lead to
serious injury and/or cause damage!
When handling, operating or carrying
out maintenance on this product,
personnel must employ safe working
practices and observe all local health &
safety requirements and regulations.
Improper operation or maintenance of
this product could be dangerous and
result in an accident causing damage to
machinery or injury or death.
The manufacturer cannot anticipate
every possible circumstance which may
represent a potential hazard. The
warnings in this manual cover the most
common potential hazards and are
therefore not all-inclusive. If the user
employs an operating procedure, an
item of equipment or a method of
working which is not specifically
recommended by the manufacturer they
must ensure that the product will not be
damaged or made unsafe and that there
is no risk to persons or property.
NEVER CHANGE ORIGINAL
COMPONENTS WITH ALTERNATIVES.

Flow Meter Enclosure User Manual v1.0
www.compressedairalliance.com 3
About the Flow Meter Enclosure
This transparent enclosure is suitable for use with Compressed Air Alliance Flow
Meters.
The enclosure protects the flow meter head from water, dust and moisture. The
enclosure is quick to install and easy to disassemble. It is suitable for indoor and
outdoor use.
Specifications
Flow Meter Enclosure
Material
Transparent PC
Working Environment
-20°C to +80°C
-4°F to +176°F
Protection
IP66
120 mm (4.7”)
199 mm (7.8”)
153 mm (6.0”)
128 mm (5.0”)

Flow Meter Enclosure User Manual v1.0
www.compressedairalliance.com 4
Installation
Unscrew face panel
Step 1
Check seal is in place
Step 2
Step 4
Remove gland nut and seals
Step 5
Feed data cable through gland,
seals and nut. Tighten nut slightly

Flow Meter Enclosure User Manual v1.0
www.compressedairalliance.com 5
Step 6
Screw data cables to connectors
Tighten glands
Attach face panel and
screw together
Check / adjust sensor
settings before attaching
face plate

Flow Meter Enclosure User Manual v1.0
www.compressedairalliance.com 6
Warranty
Compressed Air Alliance provides a 12-
month warranty for all products. The
warranty covers materials and
workmanship under the stated
operating conditions from the date of
delivery. Please report any findings
immediately and within the warranty
time.
If faults occur during the warranty
period Compressed Air Alliance will
repair or replace the defective unit,
without charge for repair labour and
material costs but there is a charge for
other services such as labour to remove
or reinstall the instrument, transport
and packing. Warranty repairs do not
extend the period of warranty.
The following damage is excluded from
this warranty:
•Improper use and non-adherence
to the user manual.
•Use of unsuitable accessories.
•Normal wear and tear
•External influences (e.g. damage
caused by vibration, damage
during transportation, excess heat
or moisture).
The warranty is cancelled when one of
the following situations occurs:
•The user opens the measurement
instrument without a direct
request written in this manual.
•Repairs or modifications are
undertaken by third parties or
unauthorised persons.
Other claims, especially damage
occurring on the outside of the
enclosure (eg dents, marks), are not
included unless responsibility is legally
binding.

www.compressedairalliance.com 7
Compressed Air Alliance Pty Ltd
Address: 1 Arthur St, Dee Why NSW 2099, Australia
E-mail: sales@compressedairalliance.com
Website: www.compressedairalliance.com