Contec AIO-160802LI-PE User manual

Ver.1.05
AIO-160802LI-PE 1
Isolated 16-bit Analog I/O Board
for PCI Express
AIO-160802LI-PE
* Specifications, color and design of the products are subject to change
without notice.
This product is a PCI Express bus-compliant interface board used to
provide an analog signal I/O, input and output function on a PC.
AIO-160802LI-PE features bus isolated 16-bit analog input 8 channels
and 16-bit analog output 2 channels.
Equipped with digital I/O and counter, this product is multifunction and
bus isolated type that provides isolation between PC and external
analog I/O circuit. This product carries buffer memory for 1K of data,
allowing sampling to be performed in a variety of trigger / clock
conditions.
Windows/Linux driver and full-fledged data logger software
“C-LOGGER” is bundled with this product. Possible to be used as a
data recording device for MATLAB and LabVIEW, with dedicated
libraries.
* The contents in this document are subject to change without notice.
* Visit the CONTEC website to check the latest details in the document.
* The information in the data sheets is as of January, 2018.
Features
Bus isolated high precision analog input 8 channels / output 2 channels,
each 4 channels for digital I/O, counter 1 channel
This product has analog input (10µsec / channel [100KSPS], 16-bit, 8
channels), analog output (10µsec [100KSPS], 16-bit, 2 channels),
analog I/O control signal (Isolation TTL level 6 channels), digital I/O (4
channels each for Isolation TTL level), counter (32-bit, Isolation TTL
level 1 channel).
Functions and connectors are compatible with PCI compatible board
ADAI16-8/2(LPCI)L
The functions same with PCI compatible board ADAI16-8/2(LPCI)L are
provided. In addition, as there is compatibility in terms of connector
shape and pin assignments, it is easy to migrate from the existing
system.
Bus isolation between PC and external I/O signals by a digital isolator
Isolation between PC and external I/O circuit by a digital isolator
improves noise tolerance.
The start/end of sampling can be controlled by software, comparison of
conversion data, an external trigger, etc.
You can select from software, comparison of conversion data or an
external trigger to control the start of sampling. You can select from
completion of sampling for a specified number of sessions, comparison
of conversion data, an external trigger or software to control the end of
sampling. The sampling cycle can be selected from the internal clock
or an external clock.
Equipped with buffer memory (1K data) that can be used in the FIFO
or RING format
The analog input block contains buffer memory (1K data) that can be
used in the FIFO or RING format. This allows for background analog
I/O that does not depend on the operation status of the software or PC.
Bus isolation between PC and external analog output circuit by a digital
isolator
Isolation between PC and external analog output circuit by a digital
isolator improves noise performance.
The start/end of sampling can be controlled by software, an external
trigger, etc.
You can select from software, an external trigger to control the start of
sampling. You can select from completion of sampling for a specified
number of sessions, an external trigger or software to control forcibly
the end of sampling. The sampling cycle can be selected from the
internal clock or an external clock.
Safety design to adjust output voltage to 0V when power supply is
turned on
To prevent the unstable voltage and the connected device of D/A
converter from fault and malfunctions when the power supply is turned
on, the circuit is designed to adjust output voltage of the analog output
to 0V.
Equipped with buffer memory (1K data) that can be used in the FIFO
or RING format
The analog output block contains buffer memory (1K data) that can be
used in the FIFO or RING format. This allows for background analog
output that does not depend on the operation status of the software or
PC.
Digital filter function included to prevent misdetection due to chattering
on external signals
A digital filter is included to prevent misdetection due to chattering on
the control signal (external trigger input signal, sampling clock input
signal, etc.), digital input signal and counter input signal.
(Except from external clock input signal and counter gate signal)
Software-based calibration function
Calibration can be all performed by software. Apart from the
adjustment information prepared before shipment, additional
adjustment information can be stored according to the use
environment.
Data logger software, Windows/Linux compatible driver libraries are
attached.
Using the bundled data logger software “C-LOGGER” allows you to
display recorded signal data in graphs, save files without any special
program. In addition, the driver library API-PAC(W32) which makes it
possible to create applications of Windows/Linux is provided.
MATLAB and LabVIEW is supported by a plug-in of dedicated library
VI-DAQ.
Using the dedicated library MATLAB and VI-DAQ makes it possible to
make a LabVIEW application.
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de
Ver.1.05
AIO-160802LI-PE 2
Specification
Item
Specifications
Analog input
Isolated specification
Bus-Isolated
Input type
Single-Ended Input
Number of input channels
8ch
Input range
Bipolar ±10V
Absolute max. input
voltage
±20V
Input impedance
1MΩor more
Resolution
16bit
Non-Linearity error *1*2
±16LSB
Conversion speed
10µsec/ch*3 [100KSPS]*4
Buffer memory
1k Word
Conversion start tr igger
Software / external trigger
Conversion stop trigger
Number of sampling times / external trigger/software
External start signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External stop signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External clock signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Analog output
Isolated specification
Bus-Isolated
Number of output channels
2ch
Output range
Bipolar ±10V
Absolute max. input
currency
±5mA
Output impedance
1Ωor less
Resolution
16bit
Non-Linear ity error *1
±5LSB
Conversion speed
10µsec [100KSPS]*4
Buffer memory
1k Word
Conversion start tr igger
Software / external trigger
Conversion stop trigger
Number of sampling times / external trigger/software
External start signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External stop signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External clock signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
*1: The non-linearity error means an error of approximately 0.1% occurs over the maximum
range at 0°C and 50°C ambient temperature.
*2: At the time of the source use of a signal which built in the high-speed operational amplifier.
*3: The required time is indicated in the analog to digital translation of one channel. When AD of
two or more channels is converted, time of the a few minutes of the channel is necessary.
Conversion time = Number of conversion channelsx10µsec
*4: SPS = Samplings Per Second. The number of data that can be converted in one second is
shown.
Dimensions
Support Software
Windows version of analog I/O driver API-AIO(WDM)
[Stored on the bundled disk driver library API-PAC(W32)]
The API-AIO(WDM) is the Windows version driver library software that
provides products in the form of Win32 API functions (DLL). Various
sample programs such as Visual Basic and Visual C++, etc and
diagnostic program *1useful for checking operation is provided.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Linux version of analog I/O driver API-AIO(LNX)
[Stored on the bundled disk driver library API-PAC(W32)]
The API-AIO(LNX) is the Linux version driver software which provides
device drivers (modules) by shared library and kernel version. Various
sample programs of gcc are provided.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Data Logger Software C-LOGGER
[Stored on the bundled disk driver library API-PAC(W32)]
C-LOGGER is a data logger software program compatible with our
analog I/O products. This program enables the graph display of
recorded signal data, zoom observation, file saving, and dynamic
transfer to the spreadsheet software “Excel”. No troublesome
programming is required.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Data Acquisition library for MATLAB ML-DAQ
(Available for downloading (free of charge) from the CONTEC web
site.)
This is the library software which allows you to use our analog I/O
device products on MATLAB by the MathWorks. Each function is offered
in accordance with the interface which is integrated in MATLAB’s Data
Acquisition Toolbox.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Data acquisition VI library for LabVIEW VI-DAQ
(Available for downloading (free of charge) from the CONTEC web
site.)
This is a VI library to use in National Instruments LabVIEW.
VI-DAQ is created with a function form similar to that of LabVIEW's
Data Acquisition VI, allowing you to use various devices without
complicated settings.
For more details on the library and download of VI-DAQ, please visit
the CONTEC’s Web site.
Packing List
Board [AIO-160802LI-PE] …1
First step guide … 1
Disk *1 [API-PAC(W32)] …1
Warranty Certificate …1
Serial Number Label …1
*1 The bundled disk contains the driver software and User’s Guide.
The standard outside dimension (L) is
the distance from the end of the board to
the outer surface of the slot cover.
[mm]
169.33(L)
110.18(H)
Item
Specifications
Digital I/O
Number of input channels
Isolated input 4ch (TTL-level positive logic)
Number of output
channels
Isolated input 4ch (TTL-level positive logic)
Counter
Number of channels
1ch
Counting system
Up count
Max. count
FFFFFFFFh (Binary data,32bit)
Number of external inputs
2 Isolation TTL-level (Gate/Up)
Gate (positive logic/level), Up (Rising edge)
Number of external
outputs
1 Isolation TTL-level Count match output (positive logic, pulse
output)
Response frequency
1MHz (Max.)
Common section
I/O address
64 ports
Interruption level
Errors and various factors, One interrupt request line as INTA
Connector
10250-52A2JL[3M]
Power consumption
3.3VDC 1100mA (Max.)
Operating condition
0 - 50°C, 10 - 90%RH (No condensation)
Bus specification
PCI Express Base Specification Rev. 1.0a x1
Dimension (mm)
169.33 (L) x 110.18(H)
Weight
120g
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de
Ver.1.05
AIO-160802LI-PE 3
List of Options
Shield Cable with 50-Pin Mini-Ribbon Connectors
at either Ends :PCB50PS-0.5P (0.5m)
:PCB50PS-1.5P (1.5m)
Shield Cable with 50-Pin Mini-Ribbon Connector
at one End :PCA50PS-0.5P (0.5m)
:PCA50PS-1.5P (1.5m)
Screw Terminal Unit (M3 x 50P) :EPD-50A *1*2
Buffer Amplifier Box for Analog Input Boards
(8ch type) :ATBA-8L *1*3
Buffer Amplifier Box for Analog Input Boards
(16ch type) :ATBA-16L *1*3
BNC Terminal Unit
(for analog input 8ch) :ATP-8L *1*4
*1 PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately.
*2 “Spring-up” type terminal is used to prevent terminal screws from falling off.
*3 An external power supply is necessary (optional AC adaptor POA200-20 prepared.)
*4 Capable of using the analog input of up to 8ch, and analog output of up to 2ch.
* Check the CONTEC’s Web site for more information on these options.
How to connect the connectors
Connector shape
To connect an external device to this board, plug the cable from the
device into the interface connector (CN1) shown below.
Connector Pin Assignment
Pin Assignments of AIO-160802LI-PE Interface Connector (CN1)
Non Connect N.C. 50
25
AO 00 Analog Output 00
Analog Ground ( for AO )
AGND
49
24
AGND
Analog Ground ( for AO )
Non Connect
N.C.
48
23
AO 01
Analog Output 01
Analog Ground ( for AO ) AGND 47
22
AGND Analog Ground ( for AO )
Analog Input 04
AI 04
46
21
AI 00
Analog Input 00
Non Connect
N.C.
45
20
N.C.
Non Connect
Analog Input 05 AI 05 44
19
AI 01 Analog Input 01
Non Connect
N.C.
43
18
N.C.
Non Connect
Analog Ground ( for AI ) AGND 42
17
AGND Analog Ground ( for AI )
Analog Ground ( for AI ) AGND 41
16
AGND Analog Ground ( for AI )
Analog Input 06
AI 06
40
15
AI 02
Analog Input 02
Non Connect
N.C.
39
14
N.C.
Non Connect
Analog Input 07 AI 07 38
13
AI 03 Analog Input 03
Non Connect
N.C.
37
12
N.C.
Non Connect
AO External Start Trigger
AO START
36
11
AI START
AI External Start Trigger
AO External Stop Trigger
AO STOP 35
10
AI STOP
AI External Stop Trigger
AO External Sampling Clock
AO EXCLK
34
9
AI EXCLK
AI External Sampling Clock
Digital Ground DGND 33
8 DGND Digital Ground
Digital Output 00 DO 00 32
7 DI 00 Digital Input 00
Digital Output 01
DO 01
31
6
DI 01
Digital Input 01
Digital Output 02
DO 02
30
5
DI 02
Digital Input 02
Digital Output 03 DO 03 29
4 DI 03 Digital Input 03
Digital Ground
DGND
28
3
DGND
Digital Ground
Counter UP Clock Input
CNT
27
2
CNT
Counter Gate Control Input
Reserved Reserved 26
1 CNT OUT
Counter Output
Analog Input00 - Analog
Input07
Analog input signal. The numbers correspond to channel numbers.
Analog Output00 - Analog
Output01
Analog output signal. The numbers correspond to channel numbers.
Analog Ground
Common analog ground for analog I/O signals.
AI External Start Trigger
Input
External trigger input for starting analog input sampling.
AI External Stop Trigger
Input
External trigger input for stopping analog input sampling.
AI External Sampling Clock
Input
External sampling clock input for analog input.
AO External Start Trigger
Input
External trigger input for starting analog output sampling.
AO External Stop Trigger
Input
External trigger input for stopping analog output sampling.
AO External Sampling Clock
Input
External sampling clock input for analog output.
Digital Input00 - Digital
Input03
Digital input signal.
Digital Output00 - Digital
Output03
Digital output signal.
Counter Gate Control Input
Gate control input signal for counter.
Counter Up Clock Input
Count-up clock input signal for counter.
Counter Output Counter output si gnal.
Digital Ground
Common digital ground for digital I/O signals, external trigger inputs, external sampling
clock inputs, and counter I/O signals.
Reserved
Reserved pin.
N.C. No connection to this pin.
CAUTION
- Do not connect any of the outputs and power outputs to the analog or digital ground.
Neither connect outputs to each other. Doing either can result in a fault.
- If analog and digital ground are shorted together, noise on the digital signals may affect the
analog signals. Accordingly, analog and digital ground should be separated.
- Leave "Reserved" pins unconnected. Connecting these pins may cause a fault in the board.
Analog Input Signal Connection
Single-ended Input
The following figure shows an example of flat cable connection.
Connect separate signal and ground wires for each analog input
channel on CN1.
Single-ended Input Connection (Flat Cable)
The following figure shows an example of shield cable connection. Use
shielded cable if the distance between the signal source and board is
long or if you want to provide better protection from noise. For each
analog input channel on CN1, connect the core wire to the signal line
and connect the shielding to ground.
Single-ended Input Connection (Shield Cable)
*1 The number of channels depends on each board. The AIO-160802LI-PE has eight channels.
CAUTION
- If the signal source contains over 1MHz signals, the signal may effect the cross-talk noise
between channels.
- If the board and the signal source receive noise or the distance between the board and the
signal source is too long, data may not be input properly.
- An input analog signal should not exceed the maximum input voltage (relate to the board
analog ground). If it exceeds the maximum voltage, the board may be damaged.
- Connect all the unused analog input channels to analog ground.
- The signal connected to an input pin may fluctuate after switching of the multiplexer. If this
occurs, shorten the cable between the signal source and the analog input pin or insert a high-
speed amplifier as a buffer between the two to reduce the fluctuation.
- Analog ground of CN1 is isolated from the ground in the PC.
Analog Output Signal Connection
This section shows how to connect the analog output signal by using a
flat cable or a shielded cable.
The following figure shows an example of flat cable connection.
Connect the signal source and ground to the CN1 analog output.
Analog Output Connection (Flat Cable)
- Connector used
50-pin mini-ribbon connector
10250-52A2JL[mfd.by 3M]
- connector
10150-6000EL[mfd. by 3M]
Compatible
Interface connector (CN1)
CN1
50 25
26 1
Analog Input 0..15*1
Analog Ground
BOARD CN1 Cable Signal Source
Analog Ground
Shield cable
Analog Input 0..15*1
BOARD CN1 Signal Source
Analog Output 0..3*2
Analog Ground
BOARD CN1 Cable Target
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de
Ver.1.05
AIO-160802LI-PE 4
The following figure shows an example of shield cable connection. Use
shielded cable if the distance between the signal source and board is
long or if you want to provide better protection from noise. For each
analog input channel on CN1, connect the core wire to the signal line
and connect the shielding to ground.
Analog Output Connection (Shield Cable)
*2 The number of channels depends on each board. The AIO-160802LI-PE has two channels.
CAUTION
- When the power supply is turned on, the output voltage of all channels becomes 0V.
- If the board or the connected wire receives noise, or the distance between the board and the
target is long, data may not be outputted properly.
- Do not short the analog output signal to analog ground, digital ground, and/or power line.
Doing so may damage the board.
- Do not connect an analog output signal to any other analog output, either on the board or on
an external device, as this may cause a fault on the board.
- Analog ground of CN1 is isolated from the ground in the PC.
Digital I/O signals, Counter signals and Control
signals Connection
The following sections show examples of how to connect digital I/O
signals, counter I/O signals, and other control I/O signals (external
trigger input signals, sampling clock input signals, etc.).
All the digital I/O signals and control signals are TTL level signals.
Digital Input Connection
Digital Output Connection
About the counter input control signal
Counter Gate Control Input (refer to the chapter 3 Connector Pin
Assignment) acts as an input that validate or invalidate the input of an
external clock for the counter. This function enables the control of an
external clock input for the counter. The external clock for the counter
is effective when input is "High", and invalid when input is "Low". If
unconnected, it is a pull-up in the board (card) and remains "High".
Therefore the external clock for the counter is effective when the
counter gate control input is not connected.
CAUTION
- Do not short the output signals to analog ground, digital ground, and/or power line. Doing so
may damage the board.
- Do not connect a digital output signal to any other d igital output, either on the board or on an
external device, as this may cause a fault on the board.
- Analog ground of CN1 is isolated from the ground in the PC.
Block Diagram
Difference from ADAI16-8/2(LPCI)L
The functions same with conventional product of ADAI16-8/2(LPCI)L
are provided with the AIO-160802LI-PE. In addition, as there is
compatibility in terms of connector shape and pin assignments, it is
easy to migrate from the existing system. So you can use the same
operating procedures as ADAI16-8/2(LPCI)L.
There are some differences in specifications as shown below.
AIO-160802LI-PE
ADAI16-8/2(LPCI)L
Power
consumption
+3.3VDC 1100mA (Max.)
+5VDC 680mA (Max.)
Bus specification
PCI Express Base
Specification Rev. 1.0a x1
PCI (32-bit, 33MHz,
Universal key shapes supported)
Dimension (mm)
169.33(L) x 110.18(H)
121.69(L) x 63.41(H)
Weight
120g
65g
Analog Ground
Shield cable
Analog Output 0..3*2
BOARD CN1 Target
DigitalInput
DigitalGround
BOARD CN1 Cable Target
10kΩ
DigitalGround
BOARD CN1 Cable Target
DigitalOutput
IOL=16mA
8 Single-end
Analog Inputs
4 Digital Inputs / 4 Digital Outputs
External Trigger Inputs
Counter Input / Output
PCI Express bus
CN1
2 Analog Outputs
DC/DC
converter
FPGA
Multiplexer
OP
Amplifer
A/D
Converter
OP
Amplifer OP
Amplifer
DA
Converter DA
Converter
Isolator
Buffer
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de

Other manuals for AIO-160802LI-PE

1

Other Contec I/O System manuals

Contec COM-2PD(PCI)H User manual

Contec

Contec COM-2PD(PCI)H User manual

Contec CPS-MC341-DS2-111 User manual

Contec

Contec CPS-MC341-DS2-111 User manual

Contec COM-2(PC)F User manual

Contec

Contec COM-2(PC)F User manual

Contec PIO-16/16L(CB)H User manual

Contec

Contec PIO-16/16L(CB)H User manual

Contec PIO-32 Series User manual

Contec

Contec PIO-32 Series User manual

Contec DIO-3232F-PE User manual

Contec

Contec DIO-3232F-PE User manual

Contec AI-1604CI2-PCI User manual

Contec

Contec AI-1604CI2-PCI User manual

Contec PIO-16/16L(PC)V User manual

Contec

Contec PIO-16/16L(PC)V User manual

Contec DIO-8D(FIT)GY User manual

Contec

Contec DIO-8D(FIT)GY User manual

Contec DIO-4/4(FIT)GY User manual

Contec

Contec DIO-4/4(FIT)GY User manual

Contec DIO-1616RL-PE User manual

Contec

Contec DIO-1616RL-PE User manual

Contec AI-1204Z-PCI User manual

Contec

Contec AI-1204Z-PCI User manual

Contec CPS-MC341-A1-111 User manual

Contec

Contec CPS-MC341-A1-111 User manual

Contec PIO-16 User manual

Contec

Contec PIO-16 User manual

Contec CONPROSYS Series User guide

Contec

Contec CONPROSYS Series User guide

Contec PO-128L(PCI)H User manual

Contec

Contec PO-128L(PCI)H User manual

Contec AD12-64(PCI) User manual

Contec

Contec AD12-64(PCI) User manual

Contec PO-32L(PCI)H User manual

Contec

Contec PO-32L(PCI)H User manual

Contec CONPROSYS CPS-MC341-DS1-111 User manual

Contec

Contec CONPROSYS CPS-MC341-DS1-111 User manual

Contec DIO-1616L-PE User manual

Contec

Contec DIO-1616L-PE User manual

Contec AI-1664LAX-USB User manual

Contec

Contec AI-1664LAX-USB User manual

Contec DA16-16L User manual

Contec

Contec DA16-16L User manual

Contec DIO-1616RYX-USB User manual

Contec

Contec DIO-1616RYX-USB User manual

Contec PIO-32H(PCI)H User manual

Contec

Contec PIO-32H(PCI)H User manual

Popular I/O System manuals by other brands

SinoCon KonNad C2000-A2-SMX2800-AC1 user manual

SinoCon

SinoCon KonNad C2000-A2-SMX2800-AC1 user manual

SMC Networks EX500-IE1 Installation & maintenance manual

SMC Networks

SMC Networks EX500-IE1 Installation & maintenance manual

Acces I/O products 104-IDI-48 Series user manual

Acces I/O products

Acces I/O products 104-IDI-48 Series user manual

Allen-Bradley 1719 Ex I/O user manual

Allen-Bradley

Allen-Bradley 1719 Ex I/O user manual

Bosch B308 user manual

Bosch

Bosch B308 user manual

Banner MultiHop Series quick start guide

Banner

Banner MultiHop Series quick start guide

Simply Automated UMI User instructions

Simply Automated

Simply Automated UMI User instructions

Smarteh LONGO LPC-2 user manual

Smarteh

Smarteh LONGO LPC-2 user manual

NCR 7649-K021 Kit instructions

NCR

NCR 7649-K021 Kit instructions

Tyco Software House AS0073-001 datasheet

Tyco

Tyco Software House AS0073-001 datasheet

WEG CFW300-IOADR Installation, configuration and operations guide

WEG

WEG CFW300-IOADR Installation, configuration and operations guide

Panasonic AV-HS04M6 operating instructions

Panasonic

Panasonic AV-HS04M6 operating instructions

Delta Electronics Analog Input/Output Mixed Module DVP06XA-S instruction sheet

Delta Electronics

Delta Electronics Analog Input/Output Mixed Module DVP06XA-S instruction sheet

INTELLIGENT CONTROL IOTRouter ZHC4013 Application guide

INTELLIGENT CONTROL

INTELLIGENT CONTROL IOTRouter ZHC4013 Application guide

National Instruments 9220 CALIBRATION PROCEDURE

National Instruments

National Instruments 9220 CALIBRATION PROCEDURE

Omron NX-ID user manual

Omron

Omron NX-ID user manual

Hitachi HS2160EIO61H user manual

Hitachi

Hitachi HS2160EIO61H user manual

National Instruments FlexRIO NI 6581B Getting started guide

National Instruments

National Instruments FlexRIO NI 6581B Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.