1. NA-9286 Specification
Class 2, adjacent to voltage rating (30Vmax.)
ITEM SPECIFICATION ITEM SPECIFICATION
Operating/Storage Temp. -20℃~55℃ / -40℃~85℃ Network Type EtherCAT
Relative Humidity 5% ~ 90% Non-Condensing Cable Category 5 Cable or Higher
Durable-vib./impact IEC68-2-6(2G) / 10G Cable Length(m) Up to 100m
EMC/ESD EN 61000-6-2:2005
EN 61000-6-4/A11:2011 Comm. Sp(Kbps) 10/100Mbps
Mount Position On the left of FnIO-S series Expansion No. Max. 63 Modules
Atmosphere Not so dusty without corrosive
gas
Interface
Connector RJ-45 Socket 2pcs
Field Supp.Volt. Class 2, 24VDC
24VDC (11VDC ~ 28.8VDC)Power Dissipation 100mA typical @24Vdc
Field Supp. Cur. Max. 10A Max. Byte size Input : 252bytes / Output : 252bytes
FnBus Sup. Cur Max. 1.5A@5Vdc Max. node 65,535
Isolation
System power to internal logic :
Non-isolation
System power to I/O driver :
Isolation
Configuration
Port
Modbus/RS-232
Node: 1 / Baud rate: 115200 / Data
bit: 8 /Parity bit: No parity /Stop bit: 1
Size 54mm ×99mm ×70mm IP Address Setting No need
Weight 167g Certification UL/cUL/CE/FCC/KCC/RoHS(EU,China)
Cautions for your Safety
Do not assemble the products and wire with power applied to the system. Else it may cause an electric arc, which can result into unexpected
and potentially dangerous action by field devices. Arching is explosion risk in hazardous locations. Be sure that the area is non-hazardous or
remove system power appropriately before assembling or wiring the modules.
Do not touch any terminal blocks or IO modules when system is running. Else it may cause the unit to an electric shock or malfunction.
Keep away from the strange metallic materials not related to the unit and wiring works should be controlled by the electric expert engineer.
Else it may cause the unit to a fire, electric shock or malfunction.
If you don’t follow the directions, it could cause a personal injury, damage to the equipment or explosion
If you disobey the instructions, there may be possibility of personal injury, damage to equipment or
explosion. Please follow below Instructions.
Check the rated voltage and terminal array before wiring. Avoid the circumstances over 55℃of temperature. Avoid placing it directly in the
sunlight.
Avoid the place under circumstances over 90% of humidity.
Do not place Modules near by the inflammable material. Else it may cause a fire.
Do not permit any vibration approaching it directly.
Go through module specification carefully, ensure inputs, output connections are made with the specifications. Use standard cables for wiring.
Use Product under pollution degree 2 environment.
Before using the unit
*We appreciate you for purchasing CREVIS Products. To use the units more effectively, please read this quick guide and refer to
the respective user manual for further details.
Warning!
Caution!
* Power Isolators must be used according to the usage of 5VDC/24VDC/48VDC or AC Voltage modules
NA-9286 Rev 1.00
Update : 2014.06.10