2. Overview
The CueScript Time Display performs as both a clock and as a tally indicator. The unit can be plugged
into a CueScript CSM or CSMV2 Monitor or into a CueScript External VITC Module via standard USB A to
USB B cable through which it receives power, tally signal, and decoded Timecode.
Clock can also be used as standalone unit and display time from its internal RTC.
3. Tally operation
When the tally signal is present, the color of all digits changes from Green to Red.
Please refer to CueScript CSM monitor guide on how to connect Tally signal.
4. Setting the Time (internal RTC)
Press and hold “SET” button for 2 seconds. Release and the first two digits will turn Red. Press the up or
down arrow to change the time in hours. When the desired hours are set, press “SET” and the hours will
go back to Green with the minutes now in Red. Pressing the up or down arrows adjusts the minutes
time. Pressing the set button will start the clock at the set time with zero seconds.
5. Setting the Brightness
Pressing and holding the up or down arrow changes the screen to Red with the word “Brightness”.
Subsequently pressing the up or down arrows adjusts the brightness up or down respectively. Pressing
the “SET” button will store the brightness level.
6. 12 or 24 Hour Time / Local Timezone Indicator
Press and hold the “12/24hr”button for 2 seconds. Upon release, the clock will change to the mode
selection “?MODE” will be displayed in Red on 6 clock digits and 2 small displays will show mode
selection. Keep pressing “12/24hr”button to cycle through the modes and press “SET” button when
finished. The new mode will be stored in memory.