Daikin SEER 14 Instruction Manual

EDUS041111_a
K-Series
- Cooling Only / Heat Pump -
SEER 14 Models

EDUS041111_a
Room Air Conditioners K-Series 1
Split-System
Room Air Conditioners
K-Series
1. Power Supply ..............................................................................................3
2. Functions.....................................................................................................4
3. Specifications ..............................................................................................6
3.1 Cooling Only ................................................................................................ 6
3.2 Heat Pump ................................................................................................... 9
4. Dimensions ...............................................................................................12
4.1 Indoor Unit.................................................................................................. 12
4.2 Outdoor Unit ............................................................................................... 13
5. Wiring Diagrams........................................................................................14
5.1 Indoor Unit.................................................................................................. 14
5.2 Outdoor Unit ............................................................................................... 15
6. Piping Diagrams........................................................................................16
6.1 Indoor Unit.................................................................................................. 16
6.2 Outdoor Unit ............................................................................................... 17
7. Capacity Tables ........................................................................................19
7.1 Cooling Only............................................................................................... 19
7.2 Heat Pump ................................................................................................. 24
7.3 Capacity Correction Factor by the Length of Refrigerant Piping (Reference) 34
Single Split Duct-Free System
Cooling Only
FTXN09KEVJU
FTXN12KEVJU
FTXN15KVJU
FTXN18KVJU
FTXN24KVJU
RKN09KEVJU
RKN12KEVJU
RKN15KEVJU
RKN18KEVJU
RKN24KEVJU
Heat Pump
FTXN09KEVJU
FTXN12KEVJU
FTXN15KVJU
FTXN18KVJU
FTXN24KVJU
RXN09KEVJU
RXN12KEVJU
RXN15KEVJU
RXN18KEVJU
RXN24KEVJU

EDUS041111_a
2Room Air Conditioners K-Series
8. Operation Limit..........................................................................................36
9. Sound Level ..............................................................................................38
9.1 Measuring Location .................................................................................... 38
9.2 Octave Band Level ..................................................................................... 39
10.Electric Characteristics..............................................................................42
11.Installation Manual ....................................................................................43
11.1 Indoor Unit - 09/12 Class............................................................................ 43
11.2 Indoor Unit -15/18/24 Class........................................................................ 57
11.3 Outdoor Unit - 09/12 Class......................................................................... 70
11.4 Outdoor Unit - 15/18/24 Class.................................................................... 81
12.Operation Manual......................................................................................93
12.1 Safety Considerations - 09/12 Class .......................................................... 93
12.2 Safety Considerations - 15/18/24 Class ................................................... 122
13.Optional Accessories ..............................................................................149
13.1 Option List ................................................................................................ 149
13.2 <BRC944B2> Wired Remote Controller................................................... 150
13.3 <KRP980B1> Interface Adaptor for Wired Remote Controller ................. 164
13.4 <KRP413AB1S> Wiring Adaptor for Timer Clock / Remote Controller .... 168
13.5 <KRP928BB2S> Interface Adaptor for DIII-NET (Residential Air Conditioner) 172
13.6 <KPW937B4> Air Direction Adjustment Grille.......................................... 175
13.7 <KPW937C4> Air Direction Adjustment Grille ......................................... 176

EDUS041111_a Power Supply
Room Air Conditioners K-Series 3
1. Power Supply
Note:
Power Supply Intake; Outdoor Unit
Indoor Unit Outdoor Unit Power Supply
Single Split
Duct-Free System
FTXN09KEVJU RKN09KEVJU
1 , 208 - 230 V, 60 Hz
FTXN12KEVJU RKN12KEVJU
FTXN15KVJU RKN15KEVJU
FTXN18KVJU RKN18KEVJU
FTXN24KVJU RKN24KEVJU
FTXN09KEVJU RXN09KEVJU
FTXN12KEVJU RXN12KEVJU
FTXN15KVJU RXN15KEVJU
FTXN18KVJU RXN18KEVJU
FTXN24KVJU RXN24KEVJU

Functions EDUS041111_a
4Room Air Conditioners K-Series
2. Functions
Category Functions
FTXN09/12KEVJU
RKN09/12KEVJU
FTXN09/12KEVJU
RXN09/12KEVJU
Category Functions
FTXN09/12KEVJU
RKN09/12KEVJU
FTXN09/12KEVJU
RXN09/12KEVJU
Basic
Function
Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°FDB) 14 ~
114.8
14 ~
114.8 Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°FWB) — 5 ~
64.4
Air-Purifying Filter with Photocatalytic
Deodorizing Function ——
PAM Control Titanium Apatite Photocatalytic
Air-Purifying Filter
Standby Electricity Saving
Compressor Oval Scroll Compressor — — Air Filter (Prefilter)
Swing Compressor Wipe-Clean Flat Panel
Rotary Compressor — — Washable Grille — —
Reluctance DC Motor MOLD PROOF Operation — —
Comfortable
Airflow
Power-Airflow Louver (Horizontal Blade)
Good-Sleep Cooling Operation — —
Power-Airflow Dual Louvers — — Timer WEEKLY TIMER — —
Power-Airflow Diffuser — — 24-Hour ON/OFF TIMER
Wide-Angle Fins (Vertical Blades) NIGHT SET Mode
Vertical Auto-Swing (Up and Down) Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
Horizontal Auto-Swing (Right and Left) — — Self-Diagnosis (Digital, LED) Display
3-D Airflow — — Wiring Error Check Function — —
COMFORT AIRFLOW Operation Anti-Corrosion Treatment of Outdoor
Heat Exchanger
Comfort
Control
Auto Fan Speed Flexibility Multi-Split / Split Type Compatible
Indoor Unit ——
Indoor Unit Quiet Operation
NIGHT QUIET Mode (Automatic) — — H/P, C/O Compatible Indoor Unit
Outdoor Unit Quiet Operation (Manual) — — Flexible Power Supply Correspondence — —
INTELLIGENT EYE Operation — — Chargeless
32.8 ft 32.8 ft
Quick Warming Function
(Preheating Operation) —Either Side Drain (Right or Left)
Hot-Start Function — Power Selection — —
Automatic Defrosting — Low Temperature Cooling Operation
(–15°C) (5°F)
Operation Automatic Operation —
Program Dry Function °F/°C Changeover R/C Temperature
Display (factory setting : °F)
Fan Only
Remote
Control
5-Rooms Centralized Controller
(Option)
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter) —— Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
Inverter POWERFUL Operation Remote Control Adaptor
(Normal Open Contact) (Option)
Priority-Room Setting — —
COOL / HEAT Mode Lock — — DIII-NET Compatible (Adaptor) (Option)
HOME LEAVE Operation — — Remote
Controller
Wireless
ECONO Operation Wired (Option)
Indoor Unit ON/OFF Button
Signal Receiving Sign
R/C with Back Light
Temperature Display — —
Note: : Holding Functions
— : No Functions

EDUS041111_a Functions
Room Air Conditioners K-Series 5
Category Functions
FTXN15/18/24KVJU
RKN15/18/24KEVJU
FTXN15/18/24KVJU
RXN15/18/24KEVJU
Category Functions
FTXN15/18/24KVJU
RKN15/18/24KEVJU
FTXN15/18/24KVJU
RXN15/18/24KEVJU
Basic
Function
Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°FDB)
14 ~
114.8
14 ~
114.8
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°FWB) — 5 ~
64.4
Air-Purifying Filter with Photocatalytic
Deodorizing Function ——
PAM Control Titanium Apatite Photocatalytic
Air-Purifying Filter
Standby Electricity Saving — —
Compressor Oval Scroll Compressor — — Air Filter (Prefilter)
Swing Compressor Wipe-Clean Flat Panel
Rotary Compressor — — Washable Grille — —
Reluctance DC Motor MOLD PROOF Operation — —
Comfortable
Airflow
Power-Airflow Louver (Horizontal Blade) — — Good-Sleep Cooling Operation — —
Power-Airflow Dual Louvers
Power-Airflow Diffuser — — Timer WEEKLY TIMER — —
Wide-Angle Fins (Vertical Blades) 24-Hour ON/OFF TIMER
Vertical Auto-Swing (Up and Down) NIGHT SET Mode
Horizontal Auto-Swing (Right and Left) — — Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
3-D Airflow — — Self-Diagnosis (Digital, LED) Display
COMFORT AIRFLOW Operation — — Wiring Error Check Function — —
Comfort
Control Auto Fan Speed Anticorrosion Treatment of Outdoor
Heat Exchanger
Indoor Unit Quiet Operation
Flexibility Multi-Split / Split Type Compatible
Indoor Unit ——
NIGHT QUIET Mode (Automatic) — — H/P, C/O Compatible Indoor Unit
Outdoor Unit Quiet Operation (Manual) — — Flexible Power Supply Correspondence — —
INTELLIGENT EYE Operation — — Chargeless 32.8 ft 32.8 ft
Quick Warming Function
(Preheating Operation) —Either Side Drain (Right or Left)
Hot-Start Function — Power Selection — —
Automatic Defrosting —
Low Temperature Cooling Operation
(–15°C) (5°F)
Operation Automatic Operation —
°F/°C Changeover R/C Temperature
Display (factory setting : °F)
Program Dry Function
Remote
Control
5-Rooms Centralized Controller
(Option)
Fan Only Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter) —— Remote Control Adaptor
(Normal Open Contact) (Option)
Inverter POWERFUL Operation DIII-NET Compatible (Adaptor) (Option)
Priority-Room Setting — — Remote
Controller
Wireless
COOL / HEAT Mode Lock — — Wired (Option)
HOME LEAVE Operation — —
ECONO Operation — —
Indoor Unit ON/OFF Button
Signal Receiving Sign
R/C with Back Light
Temperature Display — —
Note: : Holding Functions
— : No Functions

Specifications EDUS041111_a
6Room Air Conditioners K-Series
3. Specifications
3.1 Cooling Only
Note: The data are based on the conditions shown in the table below.
Model
60 Hz, 208 - 230V
Indoor Unit FTXN09KEVJU FTXN12KEVJU
Outdoor Unit RKN09KEVJU RKN12KEVJU
Capacity
Rated (Minimum ~ Nominal)
kW 2.64 (1.30 ~ 2.78) 3.52 (1.3 ~ 3.52)
Btu/h 9,000 (4,400 ~ 9,500) 12,000 (4,400 ~ 12,000)
kcal/h 2,270 (1,120 ~ 2,390) 3,030 (1,120 ~ 3,030)
Running Current (Rated) A 4.4 - 4.0 6.2 - 5.6
Power Consumption Rated (Min.~Max.) W 750 (330 ~ 800) 1,210 (330 ~ 1,210)
Power Factor % 81.9 - 81.5 93.8 - 93.9
EER (Rated) (Max.~Min.)
Btu/h·W
12.0 (13.33 ~ 11.90) 9.90 (13.33 ~ 9.90)
Energy Efficiency SEER 18.0 18.0
Piping
Connections
Liquid in. (mm) 1/4 (6.4) 1/4 (6.4)
Gas in. (mm) 3/8 (9.5) 3/8 (9.5)
Drain in. (mm) 5/8 (15.8) 5/8 (15.8)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 65.6 (20) 65.6 (20)
Min. Interunit Piping Length ft. (m) 4.9 (1.5) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 49.2 (15) 49.2 (15)
Chargeless ft. (m) 32.8 (10) 32.8 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.22 (6.2) 0.22 (6.2)
Indoor Unit FTXN09KEVJU FTXN12KEVJU
Front Panel Color White White
Airflow Rate
H
cfm
(m³/min)
325 (9.2) 328 (9.3)
M 244 (6.9) 254 (7.2)
L 162 (4.6) 184 (5.2)
SL 138 (3.9) 152 (4.3)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.20 - 0.18 0.20 - 0.18
Power Consumption (Rated) W 40 40
Power Factor % 96.2 - 96.6 96.2 - 96.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-1/8 × 30-3/8 × 7-3/4 (283 x 770 x 198) 11-1/8 × 30-3/8 × 7-3/4 (283 x 770 x 198)
Packaged Dimensions (H × W × D) in. (mm) 10-1/4× 33-1/4 (845) ×13-1/2 (260 x 845 x 343) 10-1/4× 33-1/4 (845) ×13-1/2 (260 x 845 x 343)
Weight Lbs (kg) 16 (7.3) 16 (7.3)
Gross Weight Lbs (kg) 24 (11) 24 (11)
Operation Sound H / M / L / SL dB(A) 40 / 33 / 26 / 22 42 / 34 / 27 / 23
Sound Power dB(A) 56 58
Outdoor Unit RKN09KEVJU RKN12KEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil Type FVC50K FVC50K
Charge oz (g) 12.5 (354) 12.5 (354)
Refrigerant Type R-410A R-410A
Charge Lbs (kg) 2.20 (1.0) 2.20 (1.0)
Airflow Rate H cfm
(m³/min) 921 (26.1) 921 (26.1)
Fan Type Propeller Propeller
Motor Output W 33 33
Running Current (Rated) A 4.20 - 3.82 6.00 - 5.42
Power Consumption (Rated) W 710 1,170
Power Factor % 81.3 - 80.8 93.8 - 93.9
Starting Current A 5.0 6.2
Dimensions (H × W × D) in. (mm) 21-11/16 × 25-15/16 × 10-3/4 21-11/16 × 25-15/16 × 10-3/4
Packaged Dimensions (H × W × D) in. (mm) 23-5/16 × 30-3/8 × 13-3/4 23-5/16 × 30-3/8 × 13-3/4
Weight Lbs (kg) 66 (30) 66 (30)
Gross Weight Lbs (kg) 76 (34.5) 76 (34.5)
Operation Sound dB(A) 48 50
Sound Power dB(A) 62 64
Drawing No. 3D072555 3D072556
Cooling Piping Length
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB) Outdoor ; 95°FDB(35°CDB /75°FWB(24°CWB) 25 ft (7.5)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3

EDUS041111_a Specifications
Room Air Conditioners K-Series 7
Note: The data are based on the conditions shown in the table below.
Model
60 Hz, 208 - 230V
Indoor Unit FTXN15KVJU FTXN18KVJU
Outdoor Unit RKN15KEVJU RKN18KEVJU
Capacity
Rated (Min.~Max.)
kW 4.4 (1.7 ~ 4.4) 5.28 (1.7 ~ 5.28)
Btu/h 15,000 (5,800 ~ 15,000) 18,000 (5,800 ~ 18,000)
kcal/h 3,780 (1,460 ~ 3,780) 4,540 (1,460 ~ 4,540)
Moisture Removal L/h 2.9 3.9
Running Current (Rated) A 6.11 - 5.53 7.33 - 6.63
Power Consumption
Rated
(Min.~Max.)
W 1,250 (280 ~ 1,250) 1,500 (300 ~ 1,500)
Power Factor % 98.4 - 98.3 98.4 - 98.4
EER (Rated)
(Max.~Min.)
Btu/h·W
12.0 12.0
Energy Efficiency SEER 18.0 18.0
Piping Connections
Liquid in. (mm) 1/4 (6.4) 1/4 (6.4)
Gas in. (mm) 1/2 (12.7) 1/2 (12.7)
Drain Indoor Unit in. (mm) I.D. 9/16 (14.3), O.D. 11/16 (17.5) I.D. 9/16, O.D. 11/16 (17.5)
Outdoor Unit
I.D. 11/16 (17.5) (Hole) I.D. 11/16 (17.5) (Hole)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 98.4 (30) 98.4 (30)
Min. Interunit Piping Length ft. (m) 4.9 (1.5) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 65.6 (20) 65.6 (20)
Chargeless ft. (m) 32.8 (10) 32.8 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.21 (6.0) 0.21 (6.0)
Indoor Unit FTXN15KVJU FTXN18KVJU
Front Panel Color White White
Airflow Rate
H
cfm
(m³/min)
14.7 (519) 16.2 (572)
M 438 (12.4) 480 (13.6)
L 364 (10.3) 403 (11.4)
SL 335 (9.5) 360 (10.2)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 43 43
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.17 - 0.15 0.17 - 0.15
Power Consumption (Rated) W 34 - 34 34 - 34
Power Factor % 96.2 - 98.6 96.2 - 98.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238) 11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238)
Packaged Dimensions (H × W × D) in. (mm) 13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367) 13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367)
Weight Lbs (kg) 26.5 (12) 26.5 (12)
Gross Weight Lbs (kg) 38.0 (17) 38.0 (17)
Operation Sound
H / M / L / SL dB(A) 45 / 41 / 36 / 33 45 / 41 / 36 / 33
Sound Power dB(A) 61 61
Outdoor Unit RKN15KEVJU RKN18KEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC36BXD 2YC36BXD
Motor Output W 1,100 1,100
Refrigerant Oil Type FVC50K FVC50K
Charge oz (kg) 22.1 (0.63) 22.1 (0.63)
Refrigerant Type R-410A R-410A
Charge Lbs (kg) 3.2 (1.5) 3.2 (1.5)
Airflow Rate H cfm
(m³/min) 1,472 (41.7) 1,667 (47.2)
Fan Type Propeller Propeller
Motor Output W 60 60
Running Current (Rated) A 5.94 - 5.38 7.16 - 6.48
Power Consumption (Rated) W 1,216 - 1,216 1,466 - 1,466
Power Factor % 98.4 - 98.3 98.4 - 98.4
Starting Current A 6.11 7.33
Dimensions (H × W × D) in. (mm) 23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300) 23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300)
Packaged Dimensions (H × W × D) in. (mm) 25-3/4 × 37-1/8 × 15-3/4 (654 x 943 x 400) 25-3/4 × 37-1/8 × 15-3/4 (654 x 943 x 400)
Weight Lbs (kg) 93 (42) 93 (42)
Gross Weight Lbs (kg) 100 (45.4) 100 (45.4)
Operation Sound
H dB(A) 51 53
Sound Power H dB(A) 65 67
Drawing No. 3D071519D 3D071520C
Cooling Piping Length
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB)
Outdoor ; 95°FDB(35°CDB / 75°FWB(24°CWB) 25 ft (7.5)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3

Specifications EDUS041111_a
8Room Air Conditioners K-Series
60 Hz, 208 - 230 V
Note: The data are based on the conditions shown in the table below.
Model
60 Hz, 208 - 230V
Indoor Unit FTXN24KVJU
Outdoor Unit RKN24KEVJU
Capacity
Rated (Min. ~ Max.)
kW 6.45 (1.7 ~ 6.45)
Btu/h 22,000 (5,800 ~ 22,000)
kcal/h 5,550 (1,460 ~ 5,550)
Moisture Removal L/h 4.5
Running Current (Rated) A 12.51 - 11.32
Power Consumption
Rated
(Min. ~ Max.)
W 2,560 (300 ~ 2,560)
Power Factor % 98.4 - 98.3
EER (Rated)
(Max.~Min.)
Btu/h-W 8.6
Energy Efficiency SEER 18.0
Piping
Connections
Liquid in. (mm) 1/4 (6.4)
Gas in. (mm) 1/2 (12.7)
Drain Indoor Unit in. (mm) I.D. 9/16 (14.3), O.D. 11/16 (17.5)
Outdoor Unit
I.D. 11/16 (17.5) (Hole)
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 98.4 (30)
Min. Interunit Piping Length ft. (m) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 65.6 (20)
Chargeless ft. (m) 32.8 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.21 (6.0)
Indoor Unit FTXN24KVJU
Front Panel Color White
Airflow Rate
H
cfm
(m³/min)
572 (16.2)
M480 (13.6)
L403 (11.4)
SL 360 (10.2)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.17 - 0.15
Power Consumption (Rated) W 34 - 34
Power Factor % 96.2 - 98.6
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238)
Packaged Dimensions (H × W × D) in. (mm) 13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367)
Weight Lbs (kg) 26.5 (12)
Gross Weight Lbs (kg) 38.0 (17)
Operation Sound
H / M / L / SL dB(A) 46 / 42 / 37 / 34
Sound Power dB(A) 62
Outdoor Unit RKN24KEVJU
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC36BXD
Motor Output W 1,100
Refrigerant Oil Type FVC50K
Charge oz (kg) 22.1 (0.6 kg)
Refrigerant Type R-410A
Charge Lbs (kg) 3.2 (1.5)
Airflow Rate H cfm
(m³/min) 1,667 (47.2)
Fan Type Propeller
Motor Output W 60
Running Current (Rated) A 12.34 - 11.17
Power Consumption (Rated) W 2,526 - 2,526
Power Factor % 98.4 - 98.3
Starting Current A 12.51
Dimensions (H × W × D) in. (mm) 23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300)
Packaged Dimensions (H × W × D) in. (mm) 25-3/4 × 37-3/32 × 15-3/4 (654 x 942 x 400)
Weight Lbs (kg) 93
Gross Weight Lbs (kg) 100
Operation Sound
H dB(A) 54
Sound Power H dB(A) 68
Drawing No. 3D071521C
Cooling Piping Length
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB)
Outdoor ; 95°FDB(35°CDB / 75°FWB(24°CWB) 25 ft (7.5)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3

EDUS041111_a Specifications
Room Air Conditioners K-Series 9
3.2 Heat Pump
Note: The data are based on the conditions shown in the table below.
Model
60 Hz,
208 - 230V
Indoor Unit FTXN09KEVJU FTXN12KEVJU
Outdoor Unit RXN09KEVJU RXN12KEVJU
Cooling Heating Cooling Heating
Capacity
Rated (Min.~Max.)
kW 2.64 (1.30 ~ 2.78) 2.93 (1.3 ~ 3.4) 3.52 (1.3 ~ 3.52) 3.96 (1.3 ~ 4.8)
Btu/h 9,000 (4,400 ~ 9,500) 10,000 (4,400 ~ 11,600) 12,000 (4,400 ~ 12,000) 13,500 (4,400 ~ 16,400)
kcal/h 2,270 (1,120 ~ 2,390) 2,520 (1,120 ~ 2,920) 3,030 (1,120 ~ 3,030) 3,410 (1,120 ~ 4,130)
Running Current (Rated) A 4.4 - 4.0 5.0 - 4.5 6.2 - 5.6 6.3 - 5.7
Power Consumption Rated (Min.~Max.) W 750 (330 ~ 800) 840 (310 ~ 910) 1,210 (330 ~ 1,210) 1,220 (310 ~ 1,500)
Power Factor % 81.9 - 81.5 80.8 - 81.2 93.8 - 93.9 93.1 - 93.1
EER (Rated) (Max.~Min.)
Btu/h·W
12.0 (13.33 ~ 11.90) 11.9 (14.19 ~ 12.75) 9.90 (13.33 ~ 9.90) 11.10 (14.19 ~ 10.90)
COP (Rated) (Max.~Min.) W/W 3.52 (3.94 ~ 3.48) 3.49 (4.19 ~ 3.74) 2.90 (3.94 ~ 2.90) 3.25 (4.19 ~ 3.20)
Energy Efficiency SEER 18.0 - 18.0 -
HSPF - 8.5 - 8.5
Piping
Connections
Liquid in. (mm) 1/4 (6.4) 1/4 (6.4)
Gas in. (mm) 3/8 (9.5) 3/8 (9.5)
Drain in. (mm) 5/8 (15.8) 5/8 (15.8)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 65.6 (20) 65.6 (20)
Min. Interunit Piping Length ft. (m) 4.9 (1.5) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 49.2 (15) 49.2 (15)
Chargeless ft. (m) 32.8 (10) 32.8 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/
m) 0.22 (6.2) 0.22 (6.2)
Indoor Unit FTXN09KEVJU FTXN12KEVJU
Front Panel Color White White
Airflow Rate
H
cfm
(m³/min))
325 (9.2) 342 (9.7) 328 (9.3) 357 (10.1)
M 244 (6.9) 275 (7.8) 254 (7.2)) 293 (8.3)
L 162 (4.6) 212 (6.0) 184 (5.2) 226 (6.4)
SL 138 (3.9) 187 (5.3) 152 (4.3) 201 (5.7)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.20 - 0.18 0.20 - 0.18
Power Consumption (Rated) W 40 40
Power Factor % 96.2-96.6 96.2-96.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-1/8 × 30-5/16 × 7-13/16 (283 x 770 x 198) 11-1/8 × 30-5/16 × 7-13/16 (283 x 770 x 198)
Packaged Dimensions (H × W × D) in. (mm) 10-1/4 × 33-1/4 × 13-1/2 (260 x 845 x 343) 10-1/4 × 33-1/4 × 13-1/2 (260 x 845 x 343)
Weight Lbs (kg) 16 (7) 16 (7)
Gross Weight Lbs (kg) 24 (11) 24 (11)
Operation Sound H / M / L / SL dB(A) 40 / 33 / 26 / 22 40 / 34 / 28 / 25 42 / 34 / 27 / 23 41 / 35 / 29 / 26
Sound Power dB(A) 56 56 58 57
Outdoor Unit RXN09KEVJU RXN12KEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil Type FVC50K FVC50K
Charge oz (kg) 12.5 (0.4) 12.5 (0.4)
Refrigerant Type R-410A R-410A
Charge Lbs (kg) 2.20 (1.0) 2.20 (1.0)
Airflow Rate H cfm
(m³/min) 921 (26.1) 921 (26.1) 921 (26.1) 921 (26.1)
Fan Type Propeller Propeller
Motor Output W 33 33
Running Current (Rated) A 4.20 - 3.82 4.80 - 4.32 6.00 - 5.42 6.10 - 5.52
Power Consumption (Rated) W 710 800 1,170 1,180
Power Factor % 81.3 - 80.8 80.1 - 80.5 93.8 - 93.9 93.0 - 93.0
Starting Current A 5.0 6.3
Dimensions (H × W × D) in. (mm) 21-11/16 × 25-15/16 × 10-3/4 21-11/16 × 25-15/16 × 10-3/4
Packaged Dimensions (H × W × D) in. (mm) 23-5/16 × 30-3/8 × 13-3/4 23-5/16 × 30-3/8 × 13-3/4
Weight Lbs (kg) 68 (31) 68 (31)
Gross Weight Lbs (kg) 78 (35) 78 (35)
Operation Sound dB(A) 48 48 50 51
Sound Power dB(A) 62 62 64 65
Drawing No. 3D072505 3D072506
Cooling Heating Piping Length
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB)
Outdoor ; 95°FDB(35°CDB / 75°FWB(24°CWB)
Indoor ; 70°FDB (21°CDB)
Outdoor ; 47°FDB(8.3°CDB) / 43°FWB (6 CWB) 25 ft (7.5 m)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3

Specifications EDUS041111_a
10 Room Air Conditioners K-Series
Note: The data are based on the conditions shown in the table below.
Model
60 Hz,
208 - 230V
Indoor Unit FTXN15KVJU FTXN18KVJU
Outdoor Unit RXN15KEVJU RXN18KEVJU
Cooling Heating Cooling Heating
Capacity
Rated (Min. ~ Max.)
kW 4.4 (1.7 ~ 4.4) 5.28 (1.7 ~ 6.2) 5.28 (1.7 ~ 5.28) 6.33 (1.7 ~ 7.03)
Btu/h 15,000 (5,800 ~ 15,000) 18,000 (5,800 ~ 21,200) 18,000 (5,800 ~ 18,000) 21,600 (5,800 ~ 24,000)
kcal/h 3,780 (1,460 ~ 3,780) 4,540 (1,460 ~ 5,330) 4,540 (1,460 ~ 4,540) 5,440 (1,460 ~ 6,050)
Moisture Removal L/h 2.9 — 3.9 —
Running Current (Rated) A 6.11 - 5.53 8.46 - 7.65 7.33 - 6.63 10.75 - 9.72
Power Consumption Rated (Min.~Max.) W 1,250 (280 ~ 1,250) 1,730 (260 - 2,160) 1,500 (300 ~ 1,500) 2,200 (270 ~ 2,530)
Power Factor % 98.4 - 98.3 98.3 - 98.3 98.4 - 98.4 98.4 - 98.4
EER (Rated) Btu/h-W 12.0 - 12.0 -
COP (Rated) (Max.~Min.) W/W 3.52 (6.07 ~ 3.52) 3.05 (6.54 ~ 2.87) 3.52 (5.67 ~ 3.52) 2.88 (6.30 ~ 2.78)
Energy
Efficiency
SEER 18.0 - 18.0 -
HSPF - 8.5 - 8.5
Piping
Connections
Liquid in. (mm) 1/4 (6.4) 1/4 (6.4)
Gas in. (mm) 1/2 (12.7) 1/2 (12.7)
Drain Indoor Unit in. (mm) I.D. 9/16 (14.3), O.D. 11/16 (17.5) I.D. 9/16 (14.3), O.D. 11/16 (17.5)
Outdoor Unit
I.D. 11/16 (17.5) (Hole) I.D. 11/16 (17.5) (Hole)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 98.4 (30) 98.4 (30)
Min. Interunit Piping Length ft. (m) 4.9 (1.5) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 65.6 (20) 65.6 (20)
Chargeless ft. (m) 32.8 (10) 32.8 (10)
Amount of Additional Charge of
Refrigerant oz/ft (g/m) 0.21 (5.6) 0.21 (5.6)
Indoor Unit FTXN15KVJU FTXN18KVJU
Front Panel Color White White
Airflow Rate
H
cfm
(m³/min)
519 (14.7) 568 (16.1) 572 (16.2) 614 (17.4)
M 438 (12.4) 491 (13.9) 480 (13.6 533 (15.1)
L 364 (10.3) 406 (11.5) 403 (11.4) 448 (12.7)
SL 335 (9.5) 360 (10.2) 360 (10.2) 403 (11.4)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 43 43
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.17 - 0.15 0.18 - 0.16 0.17 - 0.15 0.18 - 0.16
Power Consumption (Rated) W 34 - 34 36 - 36 34 - 34 36 - 36
Power Factor % 96.2 - 98.6 96.2 - 97.8 96.2 - 98.6 96.2 - 97.8
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238) 11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238)
Packaged Dimensions (H × W × D) in. (mm) 13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367) 13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367)
Weight Lbs (kg) 26.5 (12) 26.5 (35)
Gross Weight Lbs (kg) 38.0 (17) 38.0 (17)
Operation Sound
H / M / L / SL dB(A) 45 / 41 / 36 / 33 44 / 40 / 35 / 32 45 / 41 / 36 / 33 44 / 40 / 35 / 32
Sound Power dB(A) 61 60 61 60
Outdoor Unit RXN15KEVJU RXN18KEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC36BXD 2YC36BXD
Motor Output W 1,100 1,100
Refrigerant Oil Type FVC50K FVC50K
Charge oz (g) 22.1 (627) 22.1
Refrigerant Type R-410A R-410A
Charge Lbs (kg) 3.2 (1.5) 3.2 (1.5)
Airflow Rate H cfm
(m³/min) 1,472 (41.7) 1,501 (42.5) 1,667 (47.2) 1,501 (42.5)
Fan Type Propeller Propeller
Motor Output W 60 60
Running Current (Rated) A 5.94 - 5.38 8.28 - 7.49 7.16 - 6.48 10.57 - 9.56
Power Consumption (Rated) W 1,216 - 1,216 1,694 - 1,694 1,466 - 1,466 2,164 - 2,164
Power Factor % 98.4 - 98.3 98.4 - 98.3 98.4 - 98.4 98.4 - 98.4
Starting Current A 8.46 10.75
Dimensions (H × W × D) in. (mm) 23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300) 23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300)
Packaged Dimensions (H × W × D) in. (mm) 25-3/4 × 37-1/8 × 15-3/4 (654 x 942 x 400) 25-3/4 × 37-3/32 × 15-3/4 (654 x 942 x 400)
Weight Lbs (kg) 93 (42) 93 (42)
Gross Weight Lbs (kg) 100 (45) 100 (45)
Operation Sound
H dB(A) 51 53 53 53
Sound Power H dB(A) 65 67 67 67
Drawing No. 3D071516D 3D071517C
Cooling Heating Piping Length
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB)
Outdoor ; 95°FDB(35°CDB / 75°FWB(24°CWB)
Indoor ; 70°FDB (21°CDB)
Outdoor ; 47°FDB(8.3°CDB) / 43°FWB (6 CWB) 25 ft (7.5 m)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3

EDUS041111_a Specifications
Room Air Conditioners K-Series 11
Note: The data are based on the conditions shown in the table below.
Model
60 Hz,
208 - 230V
Indoor Unit FTXN24KVJU
Outdoor Unit RXN24KEVJU
Cooling Heating
Capacity
Rated (Min. ~ Max.)
kW 6.45 (1.7 ~ 6.45) 7.03 (1.7 ~ 7.44)
Btu/h 22,000 (5,800 ~ 22,000) 24,000 (5,800 ~ 25,400)
kcal/h 5,550 (1,460 ~ 5,550) 6,050 (1,460 ~ 6,400)
Moisture Removal L/h 4.5 —
Running Current (Rated) A 12.51 - 11.32 12.37 - 11.18
Power Consumption Rated (Min.~Max) W 2,560 (300 ~ 2,560) 2,530 (270 ~ 2,720)
Power Factor % 98.4 - 98.3 98.3 - 98.4
EER (Rated)
(Max.~Min.)
Btu/h-W 8.6 -
COP (Rated)
(Max.~Min.)
W/W 2.52 (5.67 ~ 2.52) 2.78 (6.30 ~ 2.74)
Energy
Efficiency
SEER 18.0 -
HSPF - 8.5
Piping
Connections
Liquid in. (mm) 1/4 (6.4)
Gas in. (mm) 1/2 (12.7)
Drain Indoor Unit in. (mm) I.D. 9/16 (14.3), O.D. 11/16 (17.5)
Outdoor Unit
I.D. 11/16 (17.5) (Hole)
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 98.4 (30)
Min. Interunit Piping Length ft. (m) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 65.6 (20)
Chargeless ft. (m) 32.8 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.21
Indoor Unit FTXN24KVJU
Front Panel Color White
Airflow Rate
H
cfm
(m³/min)
572 (16.2) 614 (17.4)
M 480 (13.6) 533 (15.1)
L 403 (11.4) 448 (12.7)
SL 360 (10.2) 403 (11.4)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.17 - 0.15 0.18 - 0.16
Power Consumption (Rated) W 34 - 34 36 - 36
Power Factor % 96.2 - 98.6 96.2 - 97.8
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238)
Packaged Dimensions (H × W × D) in. (mm) 13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367)
Weight Lbs (kg) 26.5 (12)
Gross Weight Lbs (kg) 38.0 (17)
Operation Sound
H / M / L / SL dB(A) 46 / 42 / 37 / 34 46 / 42 / 37 / 34
Sound Power dB(A) 62 62
Outdoor Unit RXN24KEVJU
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC36BXD
Motor Output W 1,100
Refrigerant Oil Type FVC50K
Charge oz (kg) 22.1 (0.6)
Refrigerant Type R-410A
Charge Lbs (kg) 3.2 (1.5)
Airflow Rate H cfm
(m³/min) 1,667 (47.2) 1,564 (44.3)
Fan Type Propeller
Motor Output W 60
Running Current (Rated) A 12.34 - 11.17 12.19 - 11.02
Power Consumption (Rated) W 2,526 - 2,526 2,494 - 2,494
Power Factor % 98.4 - 98.3 98.4 - 98.4
Starting Current A 12.51
Dimensions (H × W × D) in. (mm) 23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300)
Packaged Dimensions (H × W × D) in. (mm) 25-3/4 × 37-3/32 × 15-3/4 (654 x 942 x 400)
Weight Lbs (kg) 93 (42)
Gross Weight Lbs (kg) 100 (45.4)
Operation Sound
H dB(A) 54 54
Sound Power H dB(A) 68 68
Drawing No. 3D071518C
Cooling Heating Piping Length
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB)
Outdoor ; 95°FDB(35°CDB / 75°FWB(24°CWB)
Indoor ; 70°FDB (21°CDB)
Outdoor ; 47°FDB(8.3°CDB) /
43°FWB (6 CWB)
25 ft (7.5 m)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3

Dimensions EDUS041111_a
12 Room Air Conditioners K-Series
4. Dimensions
4.1 Indoor Unit
FTXN09/12KEVJU
FTXN15/18/24KVJU
AIR FLOW(INDOOR)
THE MARK (®) SHOWS PIPING DIRECTION
REAR 30-5/16(770mm)
RIGHT
LEFT
1-3/16(30mm)MIN.
INCLUDING
MOUNTING PLATE
(SPACE FOR
PERFORMANCE)
7-7/8(200mm)
1-15/16(50mm)MIN.
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR (SPACE FOR
FRONT PANEL FIXING SCREWSREQUIRED SPACE
MAINTENANCE) MAINTENANCE)
(INSIDE)
GENERAL RATING
NAME PLATE
SIGNAL RECEIVER
TERMINAL BLOCK
OPERATIONLAMP
WITH GROUND
TIMER LAMP
TERMINAL
FF
OO
N
INDOOR UNIT ON/OFF SWITCH
(INSIDE)
11-9/64(283mm)
BOTTOM
ROOM TEMP. THERMISTOR
FLAPS GAS PIPE φ3/8(φ9.5mm) CuT
(INSIDE)
DRAINHOSE
(THE LENGTH OF PIPE OUTSIDE
(CONNECTING PART
THE UNIT : ABOUT 15-23/64(390mm))
I.D.
FF
OO
N
LIQUID PIPE φ1/4(φ6.4mm) CuTO.D.
φ9/16(φ14mm)
φ5/8(φ16mm)
(THE LENGTH OF PIPE OUTSIDE THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm)) THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
MODEL NAME
SIGNAL TRANSMITTER
15/64(6mm)
21-39/64(549mm)
5/8(16mm)
PLATE
3-31/32(101mm)
11/16(18mm)2-5/16(58mm)
BLADE ANGLE
6-49/64(172mm)
UP/DOWN (AUTOMATIC)
11-9/64(283mm)
1-5/8(41.3mm)
COOLING HEATINGDRY
5°
5° 15°
45° 45°
2-9/64(54.5mm) 2-1/8(54mm)
45°
1-5/8(41.3mm)
7-3/8(187mm)
FANWALL HOLE FOR EMBEDDED PIPING
RIGHT/LEFT (MANUAL) φ2-9/16(φ65mm) HOLE
WALL HOLE
5° φ2-9/16(φ65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER
45°
45°
45°
ARC452A19 3D065951C
AIR FLOW(INDOOR)
(FOR PERFORMANCE AND MAINTENANCE)
THE MARK (®) SHOWS PIPING DIRECTION
REARREAR 41-5/16(1050)
LEFT RIGHT
(SPACE FOR MAINTENANCE)
MIN.1-3/16(30)
MIN.1-15/16(50)
MIN.1-15/16(50)
INCLUDING
(SPACE FOR MAINTENANCE)
)
INSTALLATIONPLATE
(
(SPACE FOR PERFORMANCE)
REQUIRED SPACE
9-7/16(240)
9-3/8(238)
OPERATIONLAMP
MODEL NAME
SIGNAL RECEIVER PLATE
INDOOR UNIT ON/OFF
SWITCH
TERMINAL BLOCK WITH
GROUND TERMINAL
ROOM TEMP. THERMISTOR
(INSIDE)
11-7/16(290)
(INSIDE)
TIMER LAMP DRAINHOSE FOR VP13
(CONNECTING PART
I.D.9/16,O.D.11/16)
(THE HOSE LENGTH OF OUTSIDE
THE UNIT:ABOUT 17-5/16)
GAS PIPE φ1/2 CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 13-3/8)
FRONT GRILLE FIXING SCREWS
(INSIDE)
FLAPS
LIQUID PIPE φ1/4 CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/8)
SIGNAL TRANSMITTER
41-5/16(1050)
2-1/4(58)3/4(18)BLADE ANGLES
HORIZONTAL BLADE
2-1/1635-3/16(893.5)
(30)
9/16(14.5)
1-3/16
(AUTOMATIC)
(52.5)
COOLINGHEATINGDRY
(155.5)
6-1/18
10°
(52)
5°
7-3/8(187)
2-1/16
15°
10°
40°
11-7/16(290)
5°
15° 35°
40° 55° 35°
55°
3-15/16(99.5)
2-3/8(60)
FANVERTICAL BLADE(MANUAL)
(52)
2-1/16
WIRELESS REMOTE WALL HOLE
φ3-1/8HOLE
WALL HOLE FOR
EMBEDDED PIPING
φ3-1/8HOLE
5° STANDARD LOCATIONS OF WALL HOLES
CONTROLLER
50°
5°
50°
(ARC452A20)55° 55°
3D070535A

EDUS041111_a Dimensions
Room Air Conditioners K-Series 13
4.2 Outdoor Unit
RKN09/12KEVJU, RXN09/12KEVJU
RKN15/18/24KEVJU, RXN15/18/24KEVJU
DRAIN OUTLET
(I.D 5/8 [φ15.9] HOSE FOR CONNECTION
WITH DRAIN JOINT [OPTION] )
4-HOLES FOR ANCHOR BOLTS
(M8 OR M10)
18-1/2(470) 3-25/32(96)
14-29/32(379)
7/16(11)
1-9/16(40)
11-11/16(297)
OUTDOOR AIR THERMISTORBRAND NAME LABEL MANUFACTURE'S LABEL
HANDLE
5/16(8) 1-31/32(50)10-13/16(275) 25-29/32(658) 5/16(8)15/32(12)
LIQUID
STOP VALVE
1/4 (φ6.4) CuT
SERVICE
PORT
21-21/32(550)
6-5/8(168)
6-3/32(155)
4-1/4(108)
WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4(1200)
MINIMUM SPACE FOR AIR PASSAGE
IN CASE OF REMOVING
STOP VALVE GAS STOP VALVE
3/8(φ9.5)CuT
5-7/8(150)
5-7/8(150)
3-15/16(100)
1-15/16(50)
3-15/16(100)
1-15/16(50) 1-15/16(50)1-15/16(50) UNIT=INCH(mm)
11-13/16(300)
3D071564A
WALL HEIGHT ONAIR OUTLET SIDE
MINIMUM SPACE FOR AIR PASSAGE =LESS THAN47-1/4(1200)
3-15/16(100)
DRAINOUTLET
1-15/16(50)1-15/16(50)
(I.Dφ5/8(φ15.9)HOSE FOR CONNECTION
WITH DRAINJOINT )
4-HOLES FOR FOUNDATIONBOLTS
13-3/4(350)
3-15/16(100)
1-15/16(50)
(M8OR M10)
3-9/16(91)
22-5/8(574)
13-3/4(350)
19-1/2(495)
3-15/16(100)
13-3/4(350)
10-3/4(272.5)
BRAND NAME PLATE MANUFACTURER'S
HANDLE
5/16(7.5)
11-13/16(300)
5/8(16)
9/16(15)
2-13/16(71)
31-5/16(795)GROUND TERMINAL
PLATE OUTDOOR AIR THERMISTOR
LIQUID
STOP VALVE
φ1/4(φ6.4)CuT
SERVICE
PORT
6-1/2(165)
23-7/16(595)
4-1/8(105)
1/2(13)
6-1/8(156)
13/16(20)
12-13/16(326)
(INSTALLATIONLEG
PITCH)
GAS STOP VALVE
INCASE OF REMOVING
STOP VALVE COVER φ1/2(12.7)CuT
13-7/16(342)UNIT=INCH(mm)
3D071186

Wiring Diagrams EDUS041111_a
14 Room Air Conditioners K-Series
5. Wiring Diagrams
5.1 Indoor Unit
FTXN09/12KEVJU
FTXN15/18/24KVJU
PCB 2 PCB 1
S26S27 FIELD WIRING.
BLK
19
BLK
TRANSMISSION
BLK
GRN/YLW
LED1 H1P CIRCUIT
BLK
BLK
3
FG
LED2 H2P
BLK
GRN
BLK
2
RECTIFIER H3
BLK
+– RED 3
1
BLK
OUTDOOR
9MR10 1
V1H2 WHT 2
H1 CAUTION
BLK
S1W1
NOTE THAT OPERATIONWILL
F1U
t° RESTART AUTOMATICALLY IF
X1M
3.15A
THE MAINPOWER SUPPLY IS
+–
R1T
TURNED OFF AND THENBACK
IPM200
SIGNAL
ONAGAIN.
RECEIVER
11125 10S40312916
S32 S200
S6 INDOOR
BLK BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLKBLK
YLW
BLKBLKBLK
WIRELESS
BLU
BLK
RED
WHT
ORG
FG
REMOTE
F1U
1416
S601S602
CONTROLLER
H1~H3
MM
H1P~H2P
t° M1S M1F M1F
R2T M1S
PCB1~PCB3
R1T, R2T
NOTE) S6~S602
S21 S1W
1.PCB3 SHOWS THE CASE OF
X1M
OPTIONCONNECTION.PCB 3
OPTION
: FRAME GROUND
: FUSE
: HARNESS
: PILOT LAMP
: FANMOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATIONSWITCH
: TERMINAL STRIP
: PROTECTIVE GROUND
3D065939B
M
2
3
1
X1M
OUTDOOR
INDOOR
LED1
H1P
RECTIFIER
FIELD WIRING.
S1W
Fu
3.15A
TRANSMISSION
CIRCUIT
SIGNAL
RECEIVER
LED2
H2P
WHT
R2T
S21
51
3
BRN
M1F
GRN
WIRELESS
REMOTE
CONTROLLER
H1
S6S28
PCB4
S29
S26
ORG
M
2
S1
PNK
M1S
S37
YLW
H3
S27
BLK
PCB3
t°
FG
YLW
ORG
PCB1
H2
R1T
7
RED
RED
PCB2
BLU
BLU
t°
RED
S32
WHT
S38
1
/
1
M1S
R1T, R2T
Fu
H1~H3
M1F
H1P~H2P
S1~S38
FG
X1M
S1W
PCB1~PCB4
: PROTECTIVE GROUND
: THERMISTOR
: SWING MOTOR
THE MAINPOWER SUPPLY IS
ONAGAIN.
TURNED OFF AND THENBACK
NOTE THAT OPERATIONWILL
RESTART AUTOMATICALLY IF
CAUTION
: FRAME GROUND
: HARNESS
: FUSE
: PILOT LAMP
: FANMOTOR
: PRINTED CIRCUIT BOARD
: CONNECTOR
: OPERATIONSWITCH
: TERMINAL STRIP
~~
3D038532H

EDUS041111_a Wiring Diagrams
Room Air Conditioners K-Series 15
5.2 Outdoor Unit
RKN09/12KEVJU, RXN09/12KEVJU
3D065924D
RKN15/18/24KEVJU, RXN15/18/24KEVJU
C: 3D065924E
NOTE
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
C5, C6, C119 : CAPACITOR
DB1, DB2, DB3 : DIODE BRIDGE
FU1, FU2, FU3 : FUSE
IPM1, IPM2 : INTELLIGENT POWER MODULE
L1, L2: LIVE
L1R : REACTOR
M1C : COMPRESSOR MOTOR
M1F : FAN MOTOR
MRCW, MRM30, MRM10
MRM20 : MAGNETIC RELAY
Q1L : OVERLOAD PROTECTOR
PCB1, PCB2 : PRINTED CIRCUIT BOARD
S10, S11, S12, S20
S40, S70, S80, S90
HN3 : CONNECTOR
R1T, R2T, R3T : THERMISTOR
SA1 : SURGE ABSORBER
V1, V2, V3 : VARISTOR
X1M : TERMINAL STRIP
Y1E : ELECTRONIC EXPANSION VALVE COIL
Y1R : REVERSING SOLENOID VALVE COIL
Z1C, Z2C, Z3C : FERRITE CORE
: PROTECTIVE GROUND
(OUTDOOR)
(CONDENSER)
(DISCHARGE)
FIELD WIRING
indoor
outdoor
IN CASE OF
COOLING ONLY
TYPE
IN CASE OF
HEAT PUMP
TYPE
BLK
WHT
RED
GRN/YLW
GRN
GRN
BRN
BLU
ORG
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
WHT
ORG
RED
YLW
BLK
GRY
GRY
BLK
BLK
BLK
BLK
BLK
BLK
BLK
YLW
RED
WHT
BLK
BRN
ORG
BLU
BLU
YLW
RED
FIELD WIRING
L803 IPM
indoor MRM20
N=5 FU3
Z3C
X1M DB1 L804
HL3
HL2
30A +
HL1
BLU ~+
1L1
BLK
1MRM10
HN1
V2
WHT
2L22HN3++
HN2
SC8C7
WHT ~
RED
33
1
V3
BLK
1BLK
FU1
L1BLK
3.15A BLK
L2BLK PCB2
S11 S10
BLK
DC_N1DC_P1
N=4
GRN/YLW
BLK
SA1 BLK
Z2C
PPL
E1 BLK
BRN
WVU
BLK
HL4 HN411 11
DC_N2DC_P2
BLK
E2
GRN
DB3 FU2
4
Z1C
3.15A
~+
YLW
PCB1
N=4
S70
S40
S90S20
V1374 12
16 1126
1
GRN
BLU
RED
YLW
GRY
~
X11A
outdoor
MRCW
S12
BLK
BLK
13
BLK
GRY
BLK
BLK
BLK
BLK
BLK
BLK
YEL
RED
BLU
BRN
RED
ORG
ORG
WHT
S80
BLU
31
RED
YLW
t° t°t°
S80Q1L MS
NOTE MV
3~
INCASE OF
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS. U
R1T R3TR2T W
RED
RED
COOLING ONLY
MS
C7, C8Y1E
(DISCHARGE)
(OUTDOOR)
3~
TYPE
M1F M1C
Y1S
DB1, DB3
(CONDENSER)
FU1, FU2, FU3
IPM
V1, V2, V3PCB1, PCB2
L1, L2
X1M
S10, S11, S12, S20
L803, L804
S40, S70, S80, S90 Y1E
M1C
HL3, HN3, X11A Y1S
M1F
Z1C, Z2C, Z3C
: THERMISTOR
MRCW, MRM10, MRM20
: PROTECTIVE GROUNDQ1L SA1
: CAPACITOR
: DIODE BRIDGE
: FUSE / BREAKER
: INTELLIGENT POWER MODULE
: LIVE
: REACTOR
: COMPRESSOR MOTOR
: FANMOTOR
: MAGNETIC RELAY
: OVERLOAD PROTECTOR
: PRINTED CIRCUIT BOARD
: CONNECTOR
R1T, R2T, R3T
: SURGE ABSORBER
: VARISTOR
: TERMINAL STRIP
: ELECTRONIC EXPANSIONVALVE COIL
: REVERSING SOLENOID VALVE COIL
: FERRITE CORE
_
__
_
_
3D070866

Piping Diagrams EDUS041111_a
16 Room Air Conditioners K-Series
6. Piping Diagrams
6.1 Indoor Unit
FTXN09/12KEVJU
FTXN15/18/24KVJU
INDOOR UNIT
HEAT EXCHANGER
9/32CuT
3/16CuT
9/32CuT
THERMISTOR
ON HEAT EXCH.
9/32CuT
9/32CuT
CROSS FLOW FAN
FIELD PIPING
(1/4CuT)
M
FAN MOTOR
3/8CuT
FIELD PIPING
(3/8CuT)
REFRIGERANT FLOW
COOLING
HEATING
4D066211A
INDOOR UNIT
(5/16CuT)
HEAT EXCHANGER
THERMISTOR
ON HEAT EXCH.
CROSS FLOW FAN
FIELD PIPING
FIELD PIPING
(1/4CuT)M
FAN MOTOR
(1/2CuT)(1/2CuT)
REFRIGERANT FLOW
COOLING
HEATING
4D071084

EDUS041111_a Piping Diagrams
Room Air Conditioners K-Series 17
6.2 Outdoor Unit
RKN09/12KEVJU
RKN15/18/24KEVJU
OUTDOOR UNIT
HEAT EXCHANGER
9/32CuT
9/32CuT
3/8CuT
MOTOR OPERATED
VALVE
3/16CuT
1/4CuT 1/4CuT
3/16CuT
THERMSTOR
MUFFLER
HEAT EXCHANGER
WITH
FILTER
FAN
MOTOR
M
PROPELLER FAN
1/4CuT
3/8CuT
STRAINER
FIELD PIPING
3/16CuT
(1/4CuT)
LIQUID STOP
3/8CuT
VALVE
1/4CuT
REFRIGERANT FLOW
MUFFLER MUFFLER
FIELD PIPING
3/8CuT
DISCHARGE PIPE
COOLING
COMPRESSOR
THERMISTOR
(3/8CuT)
GAS STOP
VALVEACCUMULATOR
3D065937A
OUTDOOR UNIT
(8.0)HEAT EXCHANGER OUTDOOR AIR TEMPERATURE
5/16CuT THERMISTOR
5/16CuT
(16.0)
5/8CuT
5/16CuT
(12.0)
15/32CuT
CAPILLARY TUBE 1
5/16CuT
5/16CuT 5/32CuT
(8.0)(
4.0)
5/16CuT
CAPILLARY TUBE 2
(6.0)(6.0)
REFRIGERANT FLOW
5/16CuT 5/32CuT
5/16CuT
1/4CuT1/4CuT
COOLING
(8.0)(
4.0)
CAPILLARY TUBE 3
5/16CuT 5/32CuT
HEAT
(8.0)(
4.0)
EXCHANGER
MUFFLER
WITH
FILTER
THERMISTOR
M
(6.0)
PROPELLER FAN
1/4CuT
MOTOR OPERATED
(12.0)(12.0)
VALVE
15/32CuT15/32CuT
(12.0)(12.0)
15/32CuT 15/32CuT
(6.0)
1/4CuT
MUFFLER
WITH
FILTER
(12.0)
15/32CuT
FOUR WAY
VALVE
NORMALLY:OFF FIELD PIPING
MUFFLER
(8.0)(1/4 CuT)
1/4CuT
5/16CuT
LIQUID
(6.0)(6.4)
STOP VALVE
MUFFLER
(8.0)
(12.0)
5/16CuT
15/32CuT
ACCUMULATOR FIELD PIPING
DISCHARGE PIPE
THERMISTOR (1/2 CuT)
GAS STOP VALVE (12.7)
WITH SERVICE PORT
COMPRESSOR UNIT = INCH (mm)
3D071266

Piping Diagrams EDUS041111_a
18 Room Air Conditioners K-Series
RXN09/12KEVJU
RXN15/18/24KEVJU
OUTDOOR UNIT
OUTDOOR TEMPERATURE
HEAT EXCHANGER
9/32CuT
THERMISTOR
9/32CuT
3/8CuT
MOTOR OPERATED
VALVE
3/16CuT
1/4CuT 1/4CuT
3/16CuT
MUFFLER
THERMISTOR
WITH
HEAT EXCHANGER
FILTER
FAN
MOTOR
M
PROPELLER FAN
1/4CuT
3/8CuT
3/8CuT
STRAINER
FOUR WAY
VALVE
ON : HEATING FIELD PIPING
3/16CuT
(1/4CuT)
LIQUID STOP
3/8CuT
VALVE
1/4CuT
REFRIGERANT FLOW
MUFFLER MUFFLER
FIELD PIPING
3/8CuT
DISCHARGE PIPE
COOLING
COMPRESSOR
THERMISTOR
(3/8CuT)
GAS STOP HEATING
VALVE
ACCUMULATOR
3D065936A
OUTDOOR UNIT
(8.0)HEAT EXCHANGER OUTDOOR AIR TEMPERATURE
5/16CuT THERMISTOR
5/16CuT
(16.0)
5/8CuT
5/16CuT
(12.0)
15/32CuT
CAPILLARY TUBE 1
5/16CuT
5/32CuT5/16CuT
(4.0)(8.0)
5/16CuT
CAPILLARY TUBE 2
(6.0)(6.0)REFRIGERANT FLOW
5/32CuT5/16CuT
5/16CuT 1/4CuT1/4CuT COOLING
(4.0)(8.0)
CAPILLARY TUBE 3
5/32CuT5/16CuT
HEATING
HEAT
(4.0)(8.0)
EXCHANGER
MUFFLER
WITH
FILTER
THERMISTOR
M
(6.0)
PROPELLER FAN
1/4CuT
MOTOR OPERATED
(12.0)(12.0)
VALVE
15/32CuT15/32CuT
(12.0)(12.0)
15/32CuT 15/32CuT
(6.0)
1/4CuT
FOUR WAY
MUFFLER
WITH
FILTER
VALVE
(12.0)
15/32CuT
ON:HEATING
FIELD PIPING
MUFFLER
(8.0)(1/4 CuT)
1/4CuT
5/16CuT
LIQUID
(6.0)(6.4)
STOP VALVE
MUFFLER
(8.0)
(12.0)
5/16CuT
15/32CuT
ACCUMULATOR FIELD PIPING
DISCHARGE PIPE
THERMISTOR (1/2 CuT)
GAS STOP VALVE (12.7)
WITH SERVICE PORT
COMPRESSOR UNIT = INCH (mm)
3D071265

EDUS041111_a Capacity Tables
Room Air Conditioners K-Series 19
7. Capacity Tables
7.1 Cooling Only
FTXN09KEVJU + RKN09KEVJU (60 Hz, 208 / 230 V)
3D072390
AFR 9.2
BF 0.20
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.020.02.421.940.552.421.940.622.421.940.682.411.930.712.341.890.742.211.840.80
16.022.02.832.040.582.701.980.632.581.920.692.531.900.712.461.870.752.331.820.80
18.025.02.952.140.582.832.090.642.702.040.692.652.020.722.581.990.752.461.940.80
19.426.73.012.270.582.892.220.642.762.170.692.712.150.722.64 2.12 0.75 2.52 2.07 0.81
22.030.03.192.190.593.072.150.642.952.100.702.902.090.722.822.060.752.702.020.81
24.032.03.312.140.593.192.100.653.072.060.703.022.040.732.942.020.762.821.980.81
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.268.08.275.670.538.275.670.608.275.670.688.215.620.717.965.420.747.545.090.75
60.871.69.646.430.589.226.070.638.805.730.698.635.590.718.385.400.757.965.080.75
64.4 77.0 10.05 6.48 0.58 9.63 6.14 0.64 9.21 5.81 0.69 9.04 5.68 0.72 8.79 5.49 0.75 8.37 5.18 0.76
67.0 80.0 10.26 6.56 0.58 9.84 6.23 0.64 9.42 5.91 0.69 9.25 5.78 0.72 9.00 5.60 0.75 8.58 5.30 0.76
71.6 86.0 10.88 6.30 0.59 10.46 5.99 0.64 10.04 5.70 0.70 9.87 5.58 0.72 9.62 5.41 0.75 9.20 5.14 0.76
75.2 89.6 11.29 6.08 0.59 10.87 5.79 0.65 10.46 5.51 0.70 10.29 5.41 0.73 10.04 5.25 0.76 9.62 4.99 0.76
Symbols: Note:
AFR : Airflow rate (m3/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned on the table, please calculate them with
around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Table of contents