12/24V Power Supply
Over-current Protection on All Outputs
Over-Voltage ESD Protection
RS-485/J1939/CAN Communication
Supports OmniBus Protocol
The POWERMATE 8 load handler is the latest addition to the
Digital Switching Systems family.
An innovative Australian designed and manufactured control
solution for all your electronic needs.
Rugged, flexible, reliable and specifically designed for a multitude
of applications which allows customisation for distinct digital
controlling and monitoring.
If optimal safety, cost reduction and improved adaptability is imperative to you then the POWERMATE 8 is more than
ready to undertake your next technical project.
WWW.DIGITALSWITCHING.COM.AU
WWW.DIGITALSWITCHING.COM.AU
Unit 8/27 Allgas St, Slacks Creek QLD, AUSTRALIA 4127
PO Box 1301, Slacks Creek QLD, AUSTRALIA 4127
P +61 (0)7 3290 4115 E [email protected]
S S
Digital witching ystems AustraliaS S
A D
POWERMATE 8
INTELLIGENT POWER
INTELLIGENT POWER
POWERMATE 8
S S
Digital witching ystems AustraliaS S
A D

The purpose of this document is to describe the PowerMate 8 which has been designed for the Automotive, Marine,
Mining and RV industries.
PURPOSE
PURPOSE
The standard system will be shipped with the following items:
INCLUSIONS
INCLUSIONS
Description
PowerMate 8 Module
Connection Kit
Pinout Sheet
Quantity
1
1
1
The PowerMate 8 (PM8) receives switch commands from the keypads, interfaces or CANbus and then processes
these commands based on the current system status. The response to a switch command may be an activation or
deactivation of a circuit, the start of a timed function or in systems with keyless ignition the locking or unlocking of
the system.
The PM8 then sends the system status information to turn on/off the indicator LED’s and backlights. The PM8
incorporates solid state technology which uses MOSFET’s for switching and over-current protection.
PURPOSE
PURPOSE
ELECTRICAL FEATURES
ELECTRICAL FEATURES
12/24V Power Supply
80 Ampere Total Input Current
8 MOSFETs Output Rated 20A Each (switched to Battery ONLY)
8 Digital Sense Inputs (5-30V DC)
4 Resistive Analog Inputs (300-5K ohms)
2 Voltage Analog Inputs (0-30V DC)
Over-current Protection on All Outputs (Software Settable)
Soft Start for handling high inrush devices like inductive or capacitive loading
Programmable Functions (EG. Toggle, Momentary, Timed, PWM, etc.)
Keypad Control and Indication of Output Circuit operation and faults
Over-Voltage ESD Protection
Supports CAN Protocols J1939, CANOpen, CANstd up to 500kbps
Supports Battery Voltages from minimum 10 volts to maximum 30 volts
FUNCTIONAL FEATURES
FUNCTIONAL FEATURES
Page 2: DSS-PM8_SpecSheet_V.0920_A
www.digitalswitching.com.au
Significantly less wiring and connections (up to 60%), avoiding cluttered vehicle wiring
Programmable Software generated controls, thereby easily tailoring to future needs
Real-time Monitoring, logging, diagnostic testing through a Connectivity Kit to a laptop and utilizing Keypad LED’s
CANbus Enabled
Simple Installation by Auto Electrician
Manages Output Over-Currents to avoid wiring and load damage
Designed and tested for use in multiple temperature environments
Built-in Reverse Polarity Connection Protection
Compact and Light Weight

HUMAN ERROR SCENARIOS - RESOLVED THROUGH THE POWERMATE 8
HUMAN ERROR SCENARIOS - RESOLVED THROUGH THE POWERMATE 8
Driver exits a Vehicle without applying the Park Brake
Driver drives away with Toolbox Door open
Driver drives away without Tipper Body being fully down
Operator fails to stow Tailgate Lifter in the Stowed position
Operator fails to maintain Engine Oil and Coolant Levels
Driver drives away without Crane Home or Legs Stowed
Driver inadvertently leaves Beacons or Lighting ON while driving at speed (ADR Compliance)
Driver inadvertently leaves PTO Engaged while driving at speed
Driver inadvertently leaves Diff Locks ON while driving at speed
PowerMate 8 is a digital switching solution developed for the transportation market. It provides in one package, state
of the art digital switching technology and an easy to understand user interface for designers, with an extensive and
sophisticated menu of switching solutions.
DEVICE OVERVIEW
DEVICE OVERVIEW
Page 3: DSS-PM8_SpecSheet_V.0920_A
CAN Bus
Batt J1 J2 Gnd
Output x 8
20A
Current Rating
Analog Resistive
Input x 4
Analog Voltage
Input x 2
HEADER OVERVIEW
HEADER OVERVIEW
J1 - Deutsch compatible 12 cavity receptacle (suits supplied DSS-DT06-12SA)
J2 - Deutsch compatible 12 cavity receptacle (suits supplied DSS-DT06-12SB)
X1 - 12/24 VDC M6 Power Stud
X2 - 0 VDC M6 Ground Stud
Central
Processing
Unit (CPU)
X1 X2
RS-485
Binary Input x8
1010110
01010 010
01010 0
J1
J2
Recommended Torque
Setting for Power Lug Nuts
is 1.36 N.m (12 3 in. lbs)
+
_
www.digitalswitching.com.au

PINOUT SHEET
PINOUT SHEET
PM8 Pinout
DEUTSCH
OC AMPS OUTPUT Circuit NAME
J1-3 20 Output-1
J1-4 20 Output-2
J1-5 20 Output-3
J1-6 20 Output-4
J2-1 20 Output-5
J2-2 20 Output-6
J2-3 20 Output-7
J2-4 20 Output-8
DEUTSCH
Function BINARY INPUT Circuit NAME Sense STB/G
True=H/L
J1-2 Binput-1 Binput-1
J1-1 Binput-2 Binput-2
J1-12 Binput-3 Binput-3
J1-11 Binput-4 Binput-4
J1-10 Binput-5 Binput-5
J1-9 Binput-6 Binput-6
J1-8 Binput-7 Binput-7
J1-7 Binput-8 Binput-8
DEUTSCH
Function ANALOG INPUT Circuit NAME Sense
J2-12 Analog-1 Analog-1 300R-5K
J2-11 Analog-2 Analog-2 300R-5K
(J2-8) Analog-3 Analog-3 300R-5K
(J2-7) Analog-4 Analog-4 300R-5K
J2-10 Analog-5 Analog-5 (<30V)
J2-9 Analog-6 Analog-6 (<30V)
DEUTSCH
Function COMMS Circuit NAME Sense
J2-6 OMNI_NEG Keypad OMNI_NEG
J2-5 OMNI_POS Keypad OMNI_POS
(J2-8) CAN-LO CanBus-Low Optional (250K)
(J2-7) CAN-HI CanBus-High Optional (250K)
STUD Function POWER Circuit NAME
X1 12/24V DC Power VDDA
X2 0V DC Ground
Page 4: DSS-PM8_SpecSheet_V.0920_A
SAMPLE
www.digitalswitching.com.au

DETAILED DESCRIPTION
DETAILED DESCRIPTION
PowerMate 8 has 8 MOSFET Outputs which are rated at 20 Ampere each maximum. All outputs can ONLY be
Switched to Battery. Each Output is double protected by hardware and software, i.e.
MOSFET OUTPUT
MOSFET OUTPUT
PowerMate 8 can shut down the MOSFET in case of Over-Current and
In case of software exception, the fuse will be blown to protect the circuit from further damages.
PowerMate 8 has 8 Binary Inputs which are capable of reading Digital High/Low Input. Each Binary Input can be
configured as Switch to Ground (STG)/Switch to Battery (STB) and High/Low Active independently:
BINARY INPUT
BINARY INPUT
STG Active Input examples: - Park Brake, Door Switch, Locker Doors etc.
STB Active Input examples: - Ignition, PTO, High Beam etc.
1.
2.
ALL Binary Inputs by default are configured as STB Active Inputs.
PowerMate 8 has one RS-485 channel. It can communicate with other PowerMate Series Digital Switching modules
and Keypads within the system network using the OmniBus Interface.
OMNIBUS INTERFACE
OMNIBUS INTERFACE
PowerMate 8 is default configured to communicate at 9600 bps (9600, 8-N-1).
The user can retrieve system status such as output and input pin conditions, current status, analog input
values as well as battery status.
PowerMate 8 has one CAN channel. It can communicate with other PowerMate Series Digital Switching Systems
using CAN Interface.
CAN INTERFACE
CAN INTERFACE
PowerMate 8 is default configured to communicate at 250 kbps.
PowerMate 8 supports CAN protocols such as J1939, CANOpen, CANStandard etc.
Common Status that the PowerMate Series Digital Switching Systems would be able to obtain from the
CANbus include:
Vehicle Speed
Engine Revolution Per Minute
Gear Position
Further customisation is possible to suit specific client requirements.
Page 5: DSS-PM8_SpecSheet_V.0920_A
www.digitalswitching.com.au

INSTALLATION OVERVIEW
INSTALLATION OVERVIEW
The Keypad and PowerMate units should be inspected for physical damage before installation. Any cracked, broken
or bent items on either unit should be reported to your local dealer of DSSA for proper disposition.
Ensure all power is off by disconnecting the battery(s) from the system or de-energizing the battery switch.
Prepare the unit for installation by removing all packaging materials. Keypads must be mounted to a flat surface
using a properly positioned cutout for the keypad connector pigtail. The keypad mounting studs should be secured
through the panel using 10-32 UNF nut and lock-washer. Tighten the nuts to snug only.
Do NOT exceed torque ratings as advertised of 7 1 in. lbs or 0.79 N.m as this will crack or deform the keypad,
which will cause intermittent operation.
Connect the keypad pigtail Deutsch connector to the wire harness (wire harnesses are not provided by DSSA). They
must be designed, manufactured and installed to meet the DSSA requirements as well as the specific design
requirements of the application, for length, termination, wire size, etc. It is the installers responsibility to ensure this
has been done to meet or exceed design specifications.
To mount the PowerMate, the unit must be installed in a dry, well ventilated space inside the vehicle cabin. The
ambient temperature must not exceed 70°C. It is recommended that the PowerMate be mounted with the plugs
facing in a downward direction or to the rear of the installation to minimise potential damage to the plugs, harness
and studs.
Secure the PowerMate with four bolts, nuts and washers or equivalent wood screws (not provided).
Secure the negative power side terminal to the negative power lug and secure with the nut and washer provided.
Secure the positive power side terminal to the positive power lug and secure with the nut and washer provided. Take
care to never reverse the terminal connections or reverse the order of connection.
Do NOT exceed recommended torque ratings as advertised of 12 3 in. lbs or 1.36 N.m. Over tightening will
cause the lug nut to crack or fail.
The main battery supply to the PowerMate must be protected by a switchable circuit breaker positioned at the
battery. This enables the PowerMate to be isolated from the battery in the event of charging or changing the
battery(s).
The PowerMate 8 is limited to a maximum voltage supply of 30 volts.
Plug Deutsch connectors (ensuring the correct key is selected) and then apply battery power. The system is now
ready for power and operation. Re-connect the main battery(s) to the circuit and follow the operational instructions
below.
+
_
+
_
When a button on the keypad is pressed, the circuit for that button will turn on. The indicators on all keypads for that
circuit will light up to show circuit is on. Any DSSA Keypad can turn a circuit ON or OFF.
If a circuit draws more than the rated current, the circuit will be turned OFF and the indicator LED will flash to
indicate circuit was Tripped, To REST the circuit, Press and Hold the Keypad button down for 6 seconds.
The system will also detect and indicate faulted circuits. A faulted circuit can be wither an open circuit such as a
defective device (burnt out bulb) or dead short circuit. When an Output fails, the operator can Press and Hold the
Keypad button with the Flashing LED for 6 seconds, to REST the Output. The Output can now be tried again.
GENERAL FUNCTION
GENERAL FUNCTION
To un-install the PowerMate from the system, the steps taken should be the reverse of the installation sequence.
Do NOT disconnect the power terminals while the Deutsch connectors are still attached.
Failure to disconnect the Deutsch connectors first, may cause the PowerMate to receive reverse current causing
failure of the unit and voiding any warranties.
REMOVAL
REMOVAL
Page 6: DSS-PM8_SpecSheet_V.0920_A
www.digitalswitching.com.au

SPECIFICATIONS
SPECIFICATIONS
Operating Temperature
IP Rating
Weight
PowerMate Receptacles
PowerMate Connector Plugs
-20 to +70°C
IP56
709g
Deutsch 2x DTF13-12P, 2x Studs (1x Battery, 1x Ground)
Deutsch 2 x DT06-12S (1x A & 1xB)
MECHANICAL & ENVIRONMENTAL
MECHANICAL & ENVIRONMENTAL
DIMENSIONS
DIMENSIONS
145.00
164.59
145.00
88.40
146.60
119.40
R5.00
Ø14.00
Ø6.00-4
32.00
7.00
Ø7.00-4
50.00
100.00
12.20
197.66
66.00
4.50
60.00
119.60
159.00
Page 7: DSS-PM8_SpecSheet_V.0920_A
www.digitalswitching.com.au
* Not to Scale

The first press of the button turns circuit on, and the next press turns
circuit off.
KEYPAD FUNCTIONS
KEYPAD FUNCTIONS
Toggle:
The circuit is on while the button is held down.
Momentary:
Momentary Interlock:
The circuit is on while the button is held down but will not turn on while
an interlock circuit is on.
Constant/Always ON: The circuit is always on.
Countdown: The circuit is turned on with the first press of button, and then after a
predetermined time in seconds the circuit will automatically turn OFF.
Toggle/Dimmer:
The first press turns the pin ON. Holding the button down on the second
press will decrease voltage on pin until zero power is reached. Pressing
the button a third time will turn pin OFF.
One-hot Scroll:
One press of the button turns on one circuit, and then each additional
press turns on a different circuit. Only one circuit is activated at a time.
The last press turns off all circuits.
Reverse Inclusive Scroll: With the first press of a button, all circuits are turned on. Each press
thereafter turns off one circuit. The last press turns off all circuits.
Page 8: DSS-PM8_SpecSheet_V.0920_A
www.digitalswitching.com.au

Page 9: DSS-PM8_SpecSheet_V.0920_A
Batt J1 J2 Gnd
CONNECTION DIAGRAM
CONNECTION DIAGRAM
+
-
www.digitalswitching.com.au
CAN Bus
Device
Switchable
CB 8OA
Circuit
5A
Breaker
Keypad 1 Keypad 2
Keypad 3
KPD_PWR
GND
V+ V-
J2-5 J2-6
J1-2 1 1 J1-3
J1-1 2 2 J1-4
J1-12 3 3 J1-5
J1-11 4 4 J1-6
J1-10 5 5 J2-1
J1-9 6 6 J2-2
J1-8 7 7 J2-3
J1-7 8 8 J2-4
Ohm/V
Ώ J2-12 A1
Ώ J2-11 A2
V J2-10 A5
V J2-9 A6
Ώ J2-8 A3 CANL J2-8
Ώ J2-7 A4 CANH J2-9
B
I
N
A
R
Y
I
N
P
U
T
S
P
O
W
E
R
O
U
T
P
U
T
S
P
O
W
E
R
A
N
A
L
O
G
OPTION
+V
POS
STUD
-V
NEG
STUD
SENSE
STB/STG
O.C.
AMPS
OMNI-BUS
* Illustration Example Only
ANALOG
POWER
POWER OUTPUTS
BINARY INPUTS

TROUBLESHOOTING
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
TROUBLESHOOTING STEPS
NO POWER TO KEYPADS (NO
FUNCTIONS WORK AND NO LIGHTS
TURN ON)
1. Verify Keypad is wired to the battery
properly
2. Verify battery is charged
3. Replace Keypad
WRONG OUTPUT IS ACTIVATED
WHEN BUTTON IS PRESSED
1. Improper Wiring
1. Verify Output Device is connect to
appropriate PowerMate Output Pin
KEYPAD POWERS UP BUT NO
FUNCTIONS WORK
1. Tripped circuit limits
2. Improper Wiring
3. Faulty Keypad
4. Faulty PowerMate
1. Check Device for Over-Current
2. Verify communication lines (TX/RX+
and TX/RX-) are wired to appropriate
PowerMate Pin #’s
3. Cycle Power to the Keypad and Watch
CIRCUIT IS ALWAYS TRIPPED
WHEN BUTTON IS PRESSED
(INDICATOR BLINKS AND WILL
RESET AFTER 6 SECONDS WHEN
KEY IS PRESSED)
1. Faulty Output Device
2. Short Circuit in Wiring Harness
3. Circuit Trip limit value too low for Device
1. Verify Output Device is working
properly
2. Check for Short Circuit in Wiring
Harness
3. Verify Circuit Breaker value is
sufficient for System
INDICATOR LED’S FLICKER ON AND
OFF
1. Function has No Load
2. Stray Voltage from Harness
1. Apply Load to the Function
2. Check Shielding on Communication
Lines
SYSTEM LOCKS UP
1. Low Battery Power
1. Cycle Power to the Keypad and
PowerMate
2. Verify System is at Recommended
Voltage
1. Keypad not wired/connected properly
2. Low Battery Power
3. Faulty Keypad
REVISION HISTORY
REVISION HISTORY
DATE
REVISION
COMMENTS
21/05/2018
1.0
Preliminary
24/06/2019
1.1
Draft Corrections
16/07/2019
1.2
Draft Corrections
20/05/2020
1.3
Draft Corrections
10/09/2020
1.4
Updated Installation of PM8
Page 10: DSS-PM8_SpecSheet_V.0920_A
Unit 8/27 Allgas St, Slacks Creek QLD, AUSTRALIA 4127
PO Box 1301, Slacks Creek QLD, AUSTRALIA 4127
P +61 (0)7 3290 4115 E [email protected]
S S
Digital witching ystems AustraliaS S
A D
Scan QR Code to see
our PowerMate Range
Scan QR Code to see
our Keypad Range
Table of contents
Popular Portable Generator manuals by other brands

SDMO
SDMO SH 4000 Generating set user and maintenance manual

Altrad
Altrad BELLE BULLDOG Operator's manual

SIGLENT
SIGLENT SSG5000A Service manual

Briggs & Stratton
Briggs & Stratton 30231 Wiring diagrams

GENTRON
GENTRON PRO2 Series owner's manual

Harbor Freight Tools
Harbor Freight Tools Predator 63584 user manual

Pacific Scientific
Pacific Scientific Redi-Line DA12A Installation and service manual

Wen
Wen GN5602X instruction manual

Hummer
Hummer HUMMER-3KW manual

Generac Power Systems
Generac Power Systems Guardian Ultra Source 004451-1 owner's manual

SDMO
SDMO R 340 U User and maintenance manual

American Rescue Technology
American Rescue Technology ART-10K258 instruction manual