EMC2 VNXe 3300 System Manual

This document explains the installation procedures for an EMC VNXe3300
system in a Telco rail self-supporting rack, and describes the kits available
for mounting the devices in a VNXe3300 system. These kits are for Telco rail
self-supporting racks
only.
Introduction ............................................................................................. 4
◆VNXe3300 system devices .................................................................. 4
◆Telco rail self-supporting rack .............................................................. 4
Device placement guidelines .................................................................... 5
◆Position in rack ................................................................................... 5
◆Device dimensions .............................................................................. 5
◆Power considerations .......................................................................... 5
Installing a VNXe3300 DPE in a Telco rack................................................. 7
◆VNXe3300 DPE mounting kit (DPE-TELCO-3U/3US)............................... 7
◆Installing VNXe3300 DPE mounting trays............................................. 8
◆Installing the VNXe3300 DPE in the mounting trays ............................. 9
Installing a 3U DAE in a Telco rack........................................................... 12
◆3U DAE mounting kit (FRAME-T-PDAE/PDAES) .................................... 12
◆Installing 3U DAE mounting trays....................................................... 13
◆Installing the 3U DAE in the mounting trays ....................................... 15
Installing a 2U DAE in a Telco rack........................................................... 17
◆2U DAE mounting kit (FRAME-T25DAE/T25DAES) ............................... 17
◆Installing 2U DAE mounting trays....................................................... 18
◆Installing the 2U DAE......................................................................... 20
EMC®
VNXe™3300 System
Hardware Installation Guide
for Telco Racks
P/N 300-012-893
REV 02

4
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Introduction
Introduction
This section lists the EMC® VNXe™3300 system enclosures currently supported in Telco
rail self-supporting racks (Telco racks) and provides an illustration of a typical rack.
VNXe3300 system devices
EMC offers Telco rack mounting kits for the following VNXe3300 system devices.
Telco rail self-supporting rack
Figure 1 shows a typical Telco rack built to NEMA specifications for 19 in. devices.
Figure 1 Telco rail self-supporting rack
Device Mounting kit
Kit part
number
VNXe3300 DPE (3U disk processor enclosure) DPE-TELCO-3U
DPE-TELCO-3US
150-001-930
DAE6S (3U disk-array enclosure) FRAME-T-PDAE
FRAME-T-PDAES
100-561-511
DAE5S (2U disk-array enclosure) FRAME-T25DAE
FRAME-T25DAES
150-001-911
Flange edge to
flange edge:
450.85 mm
(17.75 inches)
Mounting hole
to mounting hole:
465.074 mm
(18.31 inches)
76.2 mm to
203.2 mm
(3 inches
to 8 inches)
CL3658

Device placement guidelines
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
5
Device placement guidelines
Before attaching the mounting trays to the Telco rack, you must decide where to put them.
Where you install the devices depends on the kinds of devices that you will install.
Position in rack Devices with internal cooling fans that move air from front to back (or vice versa) and not
from beneath or above have no special cooling requirements that direct placement in the
rack. All of the storage systems and enclosures mentioned in this document have fans
that move air from front to back.
DAEs should be installed above DPEs to facilitate cable routing in the rear of the Telco
rack.
Device dimensions Dimensions and weights for VNXe3300 system devices are listed in the
Technical
Specifications and Operating Limits
document for the system, available on the EMC
Online Support website at:
http://www.emc.com/vnxesupport
Power considerations
Power distribution must support the number of outlets required for the device (2 per
enclosure) and the device power rating. Power specifications for VNXe series system
components are listed in the
Hardware Overview
document for each system, available on
the EMC Online Support website at:
http://www.emc.com/vnxesupport
For high availability, a VNXe3300 system requires at least two discrete site power circuits.
Each power supply or power/cooling module in an enclosure should connect to a separate
power distribution unit and power source; power supplies in any component should not
share a power source.
Figure 2 on page 6 shows an example AC power connection configuration.

Installing a VNXe3300 DPE in a Telco rack
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
7
Installing a VNXe3300 DPE in a Telco rack
This section describes the components of the VNXe3300 DPE mounting kit. It also
describes how to install the mounting kit in a Telco rack and how to install the DPE in the
mounting kit.
VNXe3300 DPE mounting kit (DPE-TELCO-3U/3US)
The following table lists and describes the components in the DPE mounting kit listed in
the table on page 4. Illustrations of the components of the kit can be found in Figure 3.
The quantity listed below is per enclosure.
Figure 3 3U DPE mounting kit components
Component Quantity Use
Front support tray 1 Attaches to the front of the Telco rack
Rear support tray 1 Attaches to the rear of the Telco rack
Rear fastening bracket (left and
right)
2 Attaches to the rear corner of the
DPE and DPE rear tray
#10-32 x .5 in screw 20 6 to attach the front tray to the Telco rack
6 to attach the rear tray to the Telco rack
4 to attach the front tray to the DPE
4 to attach the rear brackets to the rear corners of the DPE
CL4827

8
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a VNXe3300 DPE in a Telco rack
Installing VNXe3300 DPE mounting trays
This section describes how to install the front and rear DPE mounting trays on the Telco
rack.
Note: Be sure to allow enough room to install all the DAEs
above
the DPE.
For ease of installation, use a screwdriver with at least a 10 in. long shaft. To satisfy the precise
tolerances of the holes, hand-tighten screws until all components are in place to allow for
adjustment.
Installing the
VNXe3300 DPE front
tray
1. Align the screw holes on the outer edges of the DPE front tray with the holes on the
rack.
2. Secure the tray to the rack with six #10-32 x .5 in. long screws, three per side. Select
the most widely spread holes on the front tray that line up with holes on the rack. See
Figure 4.
Figure 4 Securing the 3U DPE front tray
Installing the
VNXe3300 DPE rear
tray
1. Align the screw holes on the outer edges of the rear tray with the holes on the rack.
Ensure that the floors of the front and rear trays are level with each other.
2. Secure the tray to the rack with six #10-32 x .5 in. long screws, three per side. See
Figure 5 on page 9.
CL4811
Mounting screw
(3 per side)

Installing a VNXe3300 DPE in a Telco rack
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
9
Figure 5 Securing the 3U DPE rear tray
Installing the VNXe3300 DPE in the mounting trays
Follow the steps below to install the DPE on the Telco rack:
The enclosure is heavy and should be installed into a rack by two people. To avoid
personal injury and/or damage to the equipment, do not attempt to lift and install the
enclosure into a rack without a mechanical lift and/or help from another person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin de
ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare danni
personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack il
contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
CL4812
Mounting screw
(3 per side)

10
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a VNXe3300 DPE in a Telco rack
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.
1. With two people, lift the enclosure up and place it on the edge of the front tray.
2. Push the enclosure in until the front flanges of the enclosure are flush against the tray.
3. Attach the front of the unit to the front tray using four #10-32 x .5 in. long screws, two
per side. See Figure 6.
Figure 6 Securing the front of the VNXe3300 DPE
4. At the back of the enclosure, attach the two rear fastening brackets to the rear corners
of the enclosure tray. See Figure 7 on page 11.
Insert one #10-32 x .5 in. long screw through each screw hole of the rear fastening
bracket and through the rear tray enclosure, but leave the screws loose enough for the
bracket to slide along the tray rail. Repeat this step for the other side.
5. Slide the brackets into the aligned notches in the DPE chassis and secure them. See
Figure 7 on page 11.
CL481
Mounting screw
(2 per side)
Front

12
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a 3U DAE in a Telco rack
Installing a 3U DAE in a Telco rack
This section describes the components of the 3U DAE (DAE6S) mounting kit. It also
describes how to install the mounting kit in a Telco rack and how to install the 3U DAE in
the mounting kit.
3U DAE mounting kit (FRAME-T-PDAE/PDAES)
The following table lists and describes the components in the 3U DAE mounting kit listed
in the table on page 4. Illustrations of the components can be found in Figure 8. The
quantity listed below is per enclosure.
Figure 8 3U DAE mounting kit components
Component Quantity Use
Front 3U support tray 1 Attaches to the front of the Telco rack
Rear 3U support tray 1 Attaches to the rear of the Telco rack
Rear fastening bracket (left and
right)
2 Attaches to the rear corner of the DAE enclosure and rear tray
#10-32 x .5 in screw 20 6 to secure front tray to the Telco rack
6 to secure rear tray to the Telco rack
4 to secure the DAE enclosure to the front tray
4 to secure the rear fastening brackets to the rear corners of the
DAE
Rear fastening bracket
(one per side)
DAE
front tray
DAE
rear tray
CL3694

Installing a 3U DAE in a Telco rack
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
13
Installing 3U DAE mounting trays
This section describes how to install the front and rear DAE trays on the Telco rack.
Install the DAE trays:
◆Directly above the DPE
or
◆Directly above another DAE
Note: For ease of installation, use a screwdriver with at least a 10 in. long shaft. To satisfy
the precise tolerances of the holes, hand-tighten screws until all components are in place
to allow for adjustment.
Installing the 3U DAE
front tray
1. Align the screw holes on the outer edges of the DAE front tray with the holes on the
rack.
2. Secure the tray to the rack with six #10-32 x .5 in. screws, three per side. Select the
three most widely spread holes on the front tray that line up with holes on the rack.
The first two screws are shown in a typical configuration in Figure 9.
Figure 9 Securing the 3U DAE front tray
Installing the 3U DAE
rear tray
1. Align the screw holes on the outer edges of the DAE rear tray with the holes on the
rack. Ensure that the floors of the front and rear trays are level with each other.
2. Secure the tray to the rack with six M5 x 12 mm screws, three per side, the first two of
which are shown in Figure 10.
CL3665
Mounting screw
(3 per side)
DAE
front tray

Installing a 3U DAE in a Telco rack
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
15
Installing the 3U DAE in the mounting trays
Follow the steps below to install a DAE enclosure on the Telco rack:
The enclosure is heavy and should be installed into a rack by two people. To avoid
personal injury and/or damage to the equipment, do not attempt to lift and install the
enclosure into a rack without a mechanical lift and/or help from another person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin de
ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare danni
personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack il
contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.
1. With two people, lift the enclosure up and place it on the edge of the enclosure front
tray.
2. Push the enclosure in until the front flanges of the enclosure are flush against the
rack.
3. Attach the front of the unit to the front tray with four #10-32 x .5 in. screws, two per
side. See Figure 11 on page 16.

16
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a 3U DAE in a Telco rack
Figure 11 Securing the 3U DAE front
4. At the back of the enclosure, attach the two rear fastening brackets to the rear corners
of the enclosure tray. See Figure 12. Insert one #10-32 x .5 in. screw through each
screw hole of the rear fastening bracket and through the rear tray enclosure. Repeat
this step for the other side.
Figure 12 Securing the 3U DAE back
CL3664
Mounting
screws
(2 per side)
A
B
CL4820
Rear
A
B
(2)
(2)
(2)

Installing a 2U DAE in a Telco rack
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
17
Installing a 2U DAE in a Telco rack
This section describes the components of the 2U DAE (DAE5S) mounting kit. It also
describes how to install the mounting kit in a Telco rack and how to install the 2U DAE in
the mounting kit.
2U DAE mounting kit (FRAME-T25DAE/T25DAES)
The following table lists and describes the components in the 2U DAE mounting kit listed
in the table on page 4. Illustrations of the components can be found in Figure 13. The
quantity listed below is per enclosure.
Figure 13 2U DAE mounting kit components
Component
Quantit
yUse
Front 2U support tray 1 Attaches to the front of the Telco rack
Rear 2U support tray 1 Attaches to the rear of the Telco rack
Rear fastening bracket (left and
right)
2 Attaches to the rear corner of the DAE enclosure and rear tray
#10-32 x .5 in. screw 20 6 to secure front tray to the Telco rack
6 to secure rear tray to the Telco rack
4 to secure the DAE to the front tray
4 to secure the rear fastening brackets to the rear corners of the
DAE
CL4815
(2)

18
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a 2U DAE in a Telco rack
Installing 2U DAE mounting trays
This section describes how to install the front and rear DAE trays on the Telco rack.
Install the DAE trays:
◆Directly above the DPE
◆Directly above another DAE.
Note: For ease of installation, use a screwdriver with at least a 10 in. long shaft. To satisfy
the precise tolerances of the holes, hand-tighten screws until all components are in place
to allow for adjustment.
Installing the 2U DAE
front tray
1. Align the screw holes on the outer edges of the DAE front tray with the holes on the
rack.
2. Secure the tray to the rack with six #10-32 x .5 in. screws, three per side. Select the
three most widely spread holes on the front tray that line up with holes on the rack.
The first two screws are shown in a typical configuration in Figure 14.
Figure 14 Securing the 2U DAE front tray
Installing the 2U DAE
rear tray
1. Align the screw holes on the outer edges of the DAE rear tray with the holes on the
rack. Ensure that the floors of the front and rear trays are level with each other.
2. Secure the tray to the rack with six M5 x 12 mm screws, three per side, the first two of
which are shown in Figure 15 on page 19.
(4)

20
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a 2U DAE in a Telco rack
Installing the 2U DAE
Follow the steps below to install a 2U DAE enclosure on the Telco rack.
The enclosure is heavy and should be installed into a rack by two people. To avoid
personal injury and/or damage to the equipment, do not attempt to lift and install the
enclosure into a rack without a mechanical lift and/or help from another person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin de
ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare danni
personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack il
contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.
1. With two people, lift the enclosure up and place it on the edge of the enclosure front
tray.
2. Push the enclosure in until the front flanges of the enclosure are flush against the
rack.
3. Attach the front of the unit to the front tray with four #10-32 x .5 in. screws, two per
side. See Figure 16 on page 21.

Installing a 2U DAE in a Telco rack
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
21
Figure 16 Securing the 2U DAE front
4. At the back of the enclosure, attach the two rear fastening brackets to the rear corners
of the enclosure tray (Figure 17). Insert one #10-32 x .5 in. screw through each screw
hole of the rear fastening bracket and through the rear tray enclosure. Repeat this step
for the other side.
Figure 17 Securing the 2U DAE back
CL4818
(4)
CL4819
(4)
(2)

22
EMC VNXe™3300 System Hardware Installation Guide for Telco Racks
Installing a 2U DAE in a Telco rack
Copyright © 2011-2012 EMC Corporation. All rights reserved. Published in the USA.
Published August, 2012
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.
The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any
kind with respect to the information in this publication, and specifically disclaims implied warranties of
merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this
publication requires an applicable software license.
EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.
For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories
section on EMC Online Support.
Table of contents
Popular Rack & Stand manuals by other brands

Lite the Nite
Lite the Nite LiteMountA LiteTouch quick start guide

Lucasey
Lucasey THFSUL2014 installation instructions

Exelium
Exelium Slide 20.XL installation instructions

AmazonBasics
AmazonBasics B076B3Q8JR manual

CARQUEST
CARQUEST Provalue 1500-CJ operating manual

FujiFilm
FujiFilm SonoSite Edge user guide