Ametek Land SPOT User manual

WATER COOLED MOUNTINGS
including Sealed to Process variant
i
SPOT
INSTALLATION GUIDE
PUBLICATION NO808274
LANGUAGE: ENGLISH
QUALITY CUSTOMER SOLUTIONS

Health and Safety Information
Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS
- before using this product. If there is any instruction which you do not understand, DO
NOT USE THE PRODUCT.
Safety Signs
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or
personal injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury to the user or users, or result in damage to the product or to property.
NOTE
Indicates a potentially hazardous situation which, if not avoided, could result in damage or loss of data.
Signs and Symbols used on equipment and Documentation
Caution, risk of electric shock.
Caution, attention to possibility of risk of damage to the product, process or surroundings. Refer
to instruction manual.
Caution, hot surface.
Protective Conductor Terminal.
Observe precautions for handling electrostatic discharge sensitive devices.
Equipment Operation
Use of this instrument in a manner not specied by AMETEK Land may be hazardous. Read and
understand the user documentation supplied before installing and operating the equipment.
The safety of any system incorporating this equipment is the responsibility of the assembler.
Protective Clothing, Face and Eye Protection
It is possible that this equipment is to be installed on, or near to, machinery or equipment operating at
high temperatures and high pressures. Suitable protective clothing, along with face and eye protection
must be worn. Refer to the health and safety guidelines for the machinery/equipment before installing
this product. If in doubt, contact AMETEK Land.
Electrical Power Supply
Before working on the electrical connections, all of the electrical power lines to the equipment must
be isolated. All the electrical cables and signal cables must be connected exactly as indicated in these
operating instructions. If in doubt, contact AMETEK Land.
Storage
The instrument should be stored in its packaging, in a dry sheltered area.
The maximum storage temperature is 10 °C (18 °F) higher than the maximum operating temperature.
The minimum storage temperature is 10 °C (18 °F) lower than the minimum operating temperature.
Refer to the Technical Specication for details of the operating temperature limits.
Unpacking
Check all packages for external signs of damage. Check the contents against the packing note.
Lifting Instructions
Where items are too heavy to be lifted manually, use suitably rated lifting equipment. Refer to the
Technical Specication for weights. All lifting should be carried out in accordance with local and national
regulations.
IMPORTANT INFORMATION - PLEASE READ

Health and Safety Information
Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS
- before using this product. If there is any instruction which you do not understand, DO
NOT USE THE PRODUCT.
Safety Signs
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or
personal injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury to the user or users, or result in damage to the product or to property.
NOTE
Indicates a potentially hazardous situation which, if not avoided, could result in damage or loss of data.
Signs and Symbols used on equipment and Documentation
Caution, risk of electric shock.
Caution, attention to possibility of risk of damage to the product, process or surroundings. Refer
to instruction manual.
Caution, hot surface.
Protective Conductor Terminal.
Observe precautions for handling electrostatic discharge sensitive devices.
Equipment Operation
Use of this instrument in a manner not specied by AMETEK Land may be hazardous. Read and
understand the user documentation supplied before installing and operating the equipment.
The safety of any system incorporating this equipment is the responsibility of the assembler.
Protective Clothing, Face and Eye Protection
It is possible that this equipment is to be installed on, or near to, machinery or equipment operating at
high temperatures and high pressures. Suitable protective clothing, along with face and eye protection
must be worn. Refer to the health and safety guidelines for the machinery/equipment before installing
this product. If in doubt, contact AMETEK Land.
Electrical Power Supply
Before working on the electrical connections, all of the electrical power lines to the equipment must
be isolated. All the electrical cables and signal cables must be connected exactly as indicated in these
operating instructions. If in doubt, contact AMETEK Land.
Storage
The instrument should be stored in its packaging, in a dry sheltered area.
The maximum storage temperature is 10 °C (18 °F) higher than the maximum operating temperature.
The minimum storage temperature is 10 °C (18 °F) lower than the minimum operating temperature.
Refer to the Technical Specication for details of the operating temperature limits.
Unpacking
Check all packages for external signs of damage. Check the contents against the packing note.
Lifting Instructions
Where items are too heavy to be lifted manually, use suitably rated lifting equipment. Refer to the
Technical Specication for weights. All lifting should be carried out in accordance with local and national
regulations.
IMPORTANT INFORMATION - PLEASE READ
Contact Us
UK - Droneld
Land Instruments International
Tel: +44 (0) 1246 417691
USA - Pittsburgh
AMETEK Land, Inc.
Tel: +1 412 826 4444
China
AMETEK Land China Service
Tel: +86 21 5868 5111 ext 122
India
AMETEK Land India Service
Tel: +91 - 80 67823240
Email: [email protected]
Web: www.ametek-land.com
For further details on all AMETEK Land oces, distributors and representatives, please visit our website.
Return of Damaged Goods
IMPORTANT If any item has been damaged in transit, this should be reported to the carrier and to the
supplier immediately. Damage caused in transit is the responsibility of the carrier not the supplier.
DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim. Save
the packing with the damaged article for inspection by the carrier.
Return of Goods for Repair
If you need to return goods for repair please contact our Customer Service Department for details of the
correct returns procedure.
Any item returned to AMETEK Land should be adequately packaged to prevent damage during transit.
You must include a written report of the problem together with your own name and contact information,
address, telephone number, email address etc.
Design and Manufacturing Standards
The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for
the design, manufacture and on-site servicing of combustion, environmental monitoring and non-contact
temperature measuring instrumentation.
Registered ISO 9001 Management System approvals apply in the USA.
UK Calibration Laboratory: UKAS 0034.
USA Calibration Laboratory: ANAB Accredited ISO/IEC 17025.
National Accreditation Board for Testing and Calibration Laboratories approvals apply in India.
Operation of radio transmitters, telephones or other electrical/electronic devices in close proximity
to the equipment while the enclosure doors of the instrument or its peripherals are open, may cause
interference and possible failure where the radiated emissions exceed the EMC directive.
The protection provided by this product may be invalidated if alterations or additions are made to the
structural, electrical, mechanical, pneumatic, software or rmware components of this system. Such
changes may also invalidate the standard terms of warranty.
Copyright
This manual is provided as an aid to owners of AMETEK Land’s products and contains information
proprietary to AMETEK Land. This manual may not, in whole or part, be copied, or reproduced without the
expressed written consent of AMETEK Land.
Copyright © 2018 Land Instruments International.
MARCOM0311, Issue 10, 13 June 2018

Water Cooled Mountings
SPOT
Contents
1 Installation Dimensions 2
1.1 Water Cooled Jacket Installation Dimensions 2
1.2 Pan & Tilt Mounting Installation Dimensions 3
2 Air&WaterSpecications 5
2.1 Maximum recommended limits 5
2.2 Maximum ambient temperature 5
3 Installing the SPOT Thermometer in the Water Cooled Mounting 7
3.1 Using an Analogue Cable 9

INSTALLATION
DIMENSIONS
1

Water Cooled Mountings
Installation Guide
SPOT
2
1Installation Dimensions
1.1 Water Cooled Jacket Installation Dimensions

3
SPOT
Water Cooled Mountings
Installation Guide
1.2 Pan & Tilt Mounting Installation Dimensions

AIR & WATER
SPECIFICATIONS
2

5
SPOT
Water Cooled Mountings
Installation Guide
2Air & Water Specifications
2.1 Maximum recommended limits
Water pressure 6 bar
Air pressure 3 bar
Water ow rate 1 litre per min / 0.26 US gal per min
Inlet water temperature 45 °C / 113 °F
Outlet water temperature 50 °C / 122 °F
2.2 Maximum ambient temperature
The maximum ambient temperature depends on water inlet temperature and
ow rate (See Fig. 2-1).
300 / 572
250 / 482
200 / 392
150 / 302
100 / 215
50 / 122
0 / 32
0 1.2
0.32
1
0.26
0.8
0.21
0.6
0.16
0.4
0.11
0.2
0.05
Maximum ambient temperature °C / °F
Flow rate l/min
Flow rate US gal/min
Inlet water
temperature
°C / °F
15 / 59
15 / 68
25 / 77
30 / 86
35 / 95
40 / 104
45 / 113
Fig. 2-1

INSTALLATION
3

7
SPOT
Water Cooled Mountings
Installation Guide
3Installing the SPOT Thermometer in the
Water Cooled Mounting
Note
TheWaterCooledMountingissuppliedttedwithacableglandforthe
PoweroverEthernet(PoE)cable,andaBlankingPlugttedintheAnalogue
Cableport.IfyouwanttouseanAnaloguecable,youwillneedtoreplace
theBlankingPlugwithaLargeConnectorSealedGland(M25)(LandPart
Nº810481),availablefromLandInstrumentsInternational.Referto
Section3.1inadditiontothefollowinginstructions.
1) Fig.3-1showsaSPOT
Thermometer,withWater
CooledMountingandPower
overEthernet(PoE)cable.
Fig.3-1
Fig.3-2
2) Unclipthefasteneronthe
Water Cooled Mounting and
openthehingedBackCap
(Fig.3-2).

Water Cooled Mountings
Installation Guide
SPOT
8
3) InserttheSPOTThermometer
into the Water Cooled
Mounting and secure it in
placewiththeSprungretainer
clip(Fig.3-3).
4) Unscrewthecableglandshell
andsplitbushfromtheWater
Cooled Mounting. Slide the
PoECablethroughthegland
shellandtthesplitbush
betweentheglandshelland
theconnector(Fig.3-4).
5) SlidethePoECablethrough
the cable gland and attach it
to the Thermometer connector
(Fig.3-5).
6) Slidethesplitbushintothe
cable gland and tighten the
gland shell. Make sure that
the cable is not stretched. Do
notover-tightenthegland
shell.
7) ClosethehingedBackCap
andsecureitinplacewiththe
fastener(Fig.3-6).
TheThermometerisnow
installed in the Water Cooled
Mounting.
IfyouareusinganAnalogue
Cableinadditionto(orinstead
of)thePoEcable,referto
Section 3.1.
Fig.3-3
Sprung retainer clip
Fig.3-4
Fig.3-6
Fig.3-5

9
SPOT
Water Cooled Mountings
Installation Guide
3.1 Using an Analogue Cable
1) FortheAnalogueCable,
unscrewtheBlankingPlug
fromtheWaterCooled
Mounting.
2) DisassembletheM25Cable
Gland.Note: The Hexagonal
Locknutisnotrequiredforthis
installation.
3) SlidetheAnalogueCable
connector through the gland
outer shell and the seal
washer(Fig.3-7).
4) Fitthesplitbushbetweenthewasherandthemainbodyofthegland.
5) InserttheAnalogueCableintotheconnectorontherearofthe
thermometer.
6) Tightenthecableglandintothebodyofthethermometer.
7) ClosethehingedBackCapandsecureitinplacewiththefastener(Fig.
3-6).
TheThermometerisnowinstalledintheWaterCooledMounting.
Fig.3-7

Blank

Blank

For a full list of international oces, please visit our website www.ametek-land.com
Copyright © 2019 LAND Instruments International.
Continuous product development may make it necessary to change these details without notice.
SPOT Water Cooled Mountings Installation Guide, Issue 6, 05 March 2019
SPOT
A FAMILY OF HIGH PRECISION MULTI-MODE
FIXED SPOT NON-CONTACT THERMOMETERS
Land Instruments International
Droneld, S18 1DJ,
England
Tel: +44 (0) 1246 417691
Email: land.enquiry@ametek.com
www.ametek-land.com
AMETEK Land - Americas
150 Freeport Road, Pittsburgh,
PA 15238, U.S.A.
Tel: +1 (412) 826 4444
www.ametek-land.com
AMETEK Land China Service
Part A1 & A4, 2nd Floor #1
No. 26 Fute 3rd Road East,
Pilot Free Trade Zone 200131
Shanghai, China
Tel: +86 21 5868 5111 ext 122
Email: land.enquiry@ametek.com
www.ametek-land.com
AMETEK Land India Service
Divyasree N R Enclave,Block A,
4th Floor, Site No 1, EPIP Industrial Area
Whiteeld, Bangalore- 560066 Karnataka,
India
Tel: +91 - 80 67823240
Email: land.enquiry@ametek.com
www.ametek-land.com
This manual suits for next models
2
Table of contents
Other Ametek Land Rack & Stand manuals