Galvin Specialised Ezy-Wash TF78WC-ESS Instruction sheet

Ezy-Wash® Food Service Tapware
PRODUCT CODES:
- TF78WC-ESS
SPECIFICATIONS
The Galvin Specialised Ezy-Wash® product range is used for hand sinks, bar sinks and more.
The wall mounted hot and cold lever mixer features a polished chrome plated body for optimum stability.
This Ezy-Wash® product is laminar flow (not aerated).
Our highly sought after lever handle design is easily operated with elbows, wrists or hands.
Quick action SBA’s include a brass jumper valve component, with red and blue indicator buttons on 150mm
lever action handles.
This unit is supplied with a wall mounted stainless steel cable to provide strength to the spout when using
the hook for bucket filling.
IMPORTANT: All Ezy-Wash® product taps are tested in accordance with AS/NZS 3718 and leave our premises in
good working order.
TECHNICAL DATA
Inlet ½” BSP – Female
Outlet Laminar Flow
Headwork Jumper Valve
Working Pressure Range (kPa) Min 50
Max 500
Working Temperature Range (°C) Min 5
Max 80
Nominal Flow Rate (LPM) 7.5
Finish Chrome
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
TOOLS REQUIRED
Power drill, Spanner & Hex Key
Thread tape or Sealant.

PRE-INSTALLATION - MOUNTING DETAILS
Main body
Hole centres must be at 215mm ±0.5mm
This is critical to ensure easy installation
Wall spuds must be ½” BSP MI and protrude
from the finished wall by no more than 15mm
Wall flange
Holes as per installation steps 4 & 5
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and
in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply
conditions must also comply to the applicable national and/or state standards. Failing to comply with these
provisions shall void the product warranty and may affect the performance of the product.
1. Fit wall flange
Apply thread tape/sealant to wall spuds to ensure
water tightness.
Remove tails from the body and fit to wall flanges.
Ensure o-rings are secured in the rear of the flanges
then fit tails and flange assemblies to the wall spuds.
Tighten tails with supplied 12mm allen key until
flanges are secured against the wall. Take care not
to overtighten.
2. Ezy-Wash® body
Check tails to ensure o-rings are fitted and
are in good condition.
Fit the Ezy-Wash® body onto the tails until it
sits flush against them. Take care not to
damage the o-rings.
Note: A male thread
connection on the tap may
be more suited. If so, please
contact us on 1300 514 074

3. Fit grub screws
Ensure the body is pushed firmly against the tail and
then secure in place with the supplied grub screws.
Ensure all four (4) grub screws are fitted with the
supplied allen key. If grub screws are missing,
contact us on 1300 514 074.
4. Fit bracket
With the supplied screws, secure the top and
lower halves of the bracket to the spout
As a reference the bracket should be first
installed 165mm from the wall as shown.
Ensure hook is facing forward and only tighten
the bracket lightly.
5. Fit wall flange
Extend the stainless steel cable upwards and place
the flange against the wall.
Ensuring there is adequate tension in the cable, mark
out the 6 mm flange holes with 48mm center
distance.
Before drilling, ensure the flange is level and is central
to the tap body.
Drill the holes, fit wall plugs, and secure the wall flange
using the supplied screws.
Note: Supplied fasteners may not be suitable for the
mounting surface. If this is the case, suitable fasteners will
need to be sourced by the installer
6. Adjust the bracket
Adjust bracket if the cable is too loose or too
tight.
Completely tighten screws to secure bracket.
Take care not to overtighten.
7. Test unit.
Once all parts are secure, open the lever handles and ensure there is flow
from both hot and cold inlets. Inspect the tap and check for any leaks.

TROUBLESHOOTING
PROBLEM CAUSE RECTIFICATION
Taps are dripping
water
Jumper valves are worn or damaged Replace jumper valve
Tap seat is damaged Refurbish tap seat using a reseating tool.
Water is leaking
from spindle
O-ring on jumper valve spindle
is damaged or worn Replace o-ring
Water is not
flowing from tap
Water is turned off Turn water on
Aerator or flow regulator is blocked by
debris
Remove aerator and/or flow regulator from tap and
remove debris. Install an inline strainer.
Spindle is difficult to
turn (jumper valve)
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Remove jumper valve, clean and regrease. Replace
o-ring. Complete SBA may need to be replaced.
Handle is loose Screw has come loose Tighten handle screw
Tap assembly
vibrating
Hook bracket is loose Tighten hook bracket ensuring adequate tension.
Grub screws have loosened Tighten 4 grub screws in body
SERVICE AND MAINTENANCE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the jumper valve for wear and damage. Replace if required.
6. Clean the spindle and body of debris.
Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product re-assembly
method.
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With
respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering
Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied
warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer’s warranty available for download from
www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free from
operational defects in workmanship and materials for the warranty period as shown on the schedule in the
manufacturer’s warranty. During the warranty period, Galvin Engineering will replace or repair any defective products
manufactured by Galvin Engineering without charge, so long as the terms of the Manufacturer’s warranty are complied
with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach
of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or consequential
damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged
if this product does not work properly, other costs resulting from labour charges, delays, vandalism, negligence, fouling
caused by foreign material, damage from adverse water conditions, chemical, electrical or any other circumstances
over which Galvin Engineering has no control. This warranty shall be invalidated by any abuse, misuse,
misapplication, improper installation or improper maintenance or alteration of the product.
Other Galvin Specialised Kitchen & Bath Fixture manuals