Harvard Bioscience BTX 630B User manual

Safety Stands
USER’S MANUAL
Publicaon 5502-002 Rev 2.0
45-0207 (Model 630B) Cuvee Safety Stand
47-0208 Extended Capacity Flatpack Safety Stand
47-0203 AgilePulse MAX Cuvee Safety Stand
47-0209 AgilePulse MAX Extended Capacity Flatpack Safety Stand
47-0610N AgilePulse PLUS Extended Capacity Flatpack Safety Stand

Thank you for invesng in a Safety Stand.
Since its founding in 1983, the main focus of BTX has been in the area of applying
controlled electric elds for genec engineering applicaons. Because of this,
we quickly established a reputaon as the technological leader in the elds of
electroporaon and electrofusion. Our systems have been installed in many
presgious instutes around the globe where they are used successfully for high
eciency transfecon, transformaon and cell fusion applicaons. We oer a
variety of waveforms, electrodes and chamber opons to provide you with the
best tools to achieve your goals.
We are vested in your success. To that end, the BTX technical support team
constantly tracks published literature for any reference to electroporaon and
electrofusion. We extract the pernent experimental condions and yields
from these papers to help us in our eorts to help you. In addion to tracking
publicaons, we are available to you for support at any me for advice in
experimental design, product recommendaons, troubleshoong, and any other
relevant technical advice.
We thank you again for your investment and we look forward to assisng you in
any way we can.
Finally, please read this manual carefully before operang. If you have any
quesons about the unit or about parcular applicaons, please contact us:
BTX
84 October Hill Road
Holliston, MA 01746 USA
Toll Free: 1-800-272-2775
Internaonal Callers: 508-893-8999
Fax: 508-429-5732
Web: www.btxonline.com
Email: [email protected]
For any customers outside the US or Canada, please call your local BTX dealer
or call us directly.
A Message from BTX
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com

1
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
Table of Contents
SUBJECT PAGE #
Warranty Informaon 2
General Safety Informaon 3
Introducon 4
Operaon: Geng Started 5
Specicaons 6
Ordering Informaon 7

2
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
Warranty Information
FOR RESEARCH USE ONLY
BTX
84 October Hill Rd
Holliston, MA 01746, USA
Phone: 1-508-893-8999
Fax: 1-800-429-5732
Web: www.btxonline.com
Warranty
BTX warranes this Safety Stand for a period of 90 days from
the date of purchase. At its opon, BTX will repair or replace the
unit if it is found to be defecve as to workmanship or materials.
This warranty does not extend to equipment which has been (a)
subjected to misuse, neglect, accident or abuse, (b) repaired or
altered by anyone other than BTX without
BTX express and prior approval, (c) used in violaon of instrucons
furnished by BTX. This warranty extends only to the original
customer purchaser. IN NO EVENT SHALL BTX BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not
allow exclusion or limitaon of incidental or consequenal damages
so the above limitaon or exclusion may not apply to you. THERE
ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS
FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states
do not allow this limitaon on an implied warranty, so the above
limitaon may not apply to you. Without liming the generality
of the foregoing, BTX shall not be liable for any claims of any kind
whatsoever, as to the equipment delivered or for non-delivery of
equipment, and whether or not based on negligence. Warranty is
void if the instrument is changed in any way from its original factory
design or if repairs are aempted without wrien authorizaon
by BTX. Warranty is void if parts, connecons, or power supplies
not manufactured by BTX are used with the BTX Safety Stand. If a
defect arises within the warranty period, promptly contact BTX, 84
October Hill Road, Holliston, Massachuses, USA 01746-1388 using
our toll free number 1-800-272-2775 (US Only) or 508-893-8999.
(E-mail: [email protected]). Goods will not be accepted for
return unless an RMA (Returned Materials Authorizaon) number
has been issued by our customer service department. The customer
is responsible for shipping charges. Please allow a reasonable
period of me for compleon of repairs, replacement and return.
If the unit is replaced, the replacement unit is covered only for the
remainder of the original warranty period dang from the purchase
of the original device. This warranty gives you specic rights, and
you may also have other rights, which vary from state to state.
Out of Warranty Service
Proceed exactly as for Warranty Service above. If our service
department can assist you by phone or other correspondence,
we will be glad to help at no charge. Repair service will be billed
on the basis of labor and materials. A complete statement of
me spent and materials used will be supplied. Shipment to BTX
should be prepaid. Your bill will include return shipment freight
charges. Disassembly by the user is prohibited. Service should
only be carried out by experienced BTX technicians.
Repair Facilies and Parts
BTX stocks replacement and repair parts. When ordering, please
describe parts as completely as possible, preferably using our part
numbers. If praccal, enclose a sample photo or drawing.
Cauon Noce
The BTX Safety Stand is intended for laboratory use only and can
be used in research and development applicaons. These systems
have been designed to meet the standards for electromagnec
compability (EMC) and safety. This product should not be used
in the presence of a ammable atmosphere such as an anesthec
mixture with air, oxygen, or nitrous oxide.

3
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
Safety Information
Please read the following safety precauons to ensure proper use of
your Safety Stand. If the equipment is used in a manner not specied,
the protecon provided by the equipment may be impaired.
To Prevent Hazard or Injury
Make Proper Connecons
Make sure all connecons are made properly and securely.
Any signal wire connecons to the unit must be no longer than
three meters.
Observe All Terminal Rangs
To avoid re or shock hazard, observe all rangs and markings on
the product or in this manual before using the device.
Avoid Exposed Circuitry
Do not touch any electronic circuitry inside of the product. Do not
insert ngers or try to remove electrode or sample during pulsing
sequence.
Do Not Operate with Suspected Failures
If damage is suspected on or to the product do not operate the
product. Contact qualied service personnel to perform inspecon.
Place Product in Proper Environment
Review the operang manual for guidelines for proper operang
environments. Do not operate in wet/damp condions.
Wear proper eye protecon
during electroporaon
Arcing Can Occur at High Voltages
An unfavorable combinaon of parameters such as high voltage
sengs and a small sample volume with a highly conducve
medium might lead to ashover between the electrodes (ARC) and/
or explosive evaporaon of the medium. Reduce voltage or pulse
length to avoid repeang this condion.
Observe all Warning Labels on Product
Read all labels on product to ensure proper usage.
High Voltage Risk
These BTX Safety Stands are designed to connect to a high voltage
power supply adjustable to 3,000 V. High voltage power supplies
present a serious risk of personal injury if not used in accordance
with design and/or use specicaons, if used in applicaons on
products for which they are not intended or designed, or if they
are used by untrained or unqualied personnel.
• The user must read this manual carefully before the
instruments are placed into operaon.
• Removing the cover will void the warranty.
• Do not connect or disconnect the high voltage cable with
the high voltage enabled.
• To connect or disconnect the cable, turn line power o and
unplug line (mains) cord.
• Do not touch the electrode p while the waveforms are
being applied.
If there are any quesons about the operaon of this equipment,
call BTX Customer service at 1-800-272-2775, or 1-508-893-8999.
Cauon Noce
The BTX Safety Stand is intended for laboratory use only and can
be used in research and development applicaons. These systems
have been designed to meet the standards for electromagnec
compability (EMC) intended for laboratory equipment
applicaons as well as the applicable safety requirements for
electrical equipment for measurement, control, and laboratory
use. The unit itself does not generate waste, but may be used to
treat samples that are hazardous. Please use appropriate PPE and
ensure disposal in accordance with local regulaons and pracces.
This product should not be used in the presence of a ammable
atmosphere such as an anesthec mixture with air, oxygen, or
nitrous oxide.
Cauon Risk
of Electric Shock
Cauon

4
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
The BTX Safety Stand is a safety device for use with BTX disposable cuvees and atpack chambers. Its unique design ensures that no
current can be delivered unless the lid is closed, therefore protecng the user from high voltages. Up to two cuvees can be electroporated
at once, thus decreasing experimentaon mes. Please refer to the Product Compability table below for compable BTX electroporators
and accessories.
Introduction
Product Compability
BTX Safety Stand Item # 45-0207 47-0208 47-0203 47-0209 47-0610N
Compable
BTX Generators
ECM 399
ECM 630
ECM 830
ECM 2001*
Gemini X2
* When used with
F/F adapters,
Item 45-0088,
Sold separately
ECM 399
ECM 630
ECM 830
ECM 2001**
Gemini X2
** When used
with included
F/F adapters,
Item 45-0088
AgilePulse MAX
ECM 2001+
AgilePulse MAX
ECM 2001+
AgilePulse PLUS
Compable
BTX Cuvees
All 1 mm, 2 mm,
and 4 mm gap
BTX cuvees
All 1 mm, 2 mm,
and 4 mm gap
BTX cuvees
All 1 mm, 2 mm,
and 4 mm gap
BTX cuvees
All 1 mm, 2 mm,
and 4 mm gap
BTX cuvees
All 1 mm, 2 mm,
and 4 mm gap
BTX cuvees
Compable
BTX Flatpacks
45-0109
45-0110
45-0109
45-0110
47-0206
45-0109
45-0110
45-0109
45-0110
47-0206
45-0109
45-0110
47-0206
Note: For compability with older models, please contact BTX Technical Support.

5
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
Warning High Voltage
Make sure the BTX electroporator
is switched o before connuing.
1. Aach the safety stand cables to the output on the rear or
the front panel of the electroporator depending on the BTX
electroporator being used. For AgilePulse MAX, AgilePulse PLUS,
and ECM 2001+, also connect interlock cable to front panel of
electroporator. For ECM 399, ECM 630, ECM 830, and Gemini
electroporators, connect safety stand cables directly to generator
high voltage output ports. For Legacy ECM 2001 connect safety
stand cables to HV output cables using F/F adapters.
2. Using asepc technique, pipee the correct volume of cell
suspension and reagents into the cuvee or atpack chamber.
If using a cuvee or 10 ml atpack chamber (Item 47-0206),
replace the cap.
3. Open the safety stand shield and place the cuvee or atpack
chamber between the metal contacts. Adjust the distance
between the contacts using the black roller. (Note: the
adjustment will remain the same aer the rst me, do not
readjust the roller with every cuvee. However, check contact
periodically to ensure good current ow). Close the safety
stand shield.
4. Switch on the BTX electroporator. Check that all instrument
sengs and connecons are correct. Deliver electroporaon
pulse protocol by pressing the appropriate START or PULSE
buon depending on the BTX electroporator being used.
5. Aer the pulse delivery is complete, remove the cuvee or
atpack chamber from the safety stand. Use a pipee to remove
the pulsed cells. Treat the pulsed cells according to the protocol.
6. Discard the cuvee, pipee and/or atpack chamber in
a biohazard container. Refer to your local instuon’s
environmental health and safety regulaons for proper
disposal pracces.
7. Unplug safety stand from electroporator. Clean plasc lid with
ethanol and deionized water as needed. Please contact Technical
Support for guidance regarding cleaning procedure for safety
stand metal electrode contacts.
Operation: Getting Started

6
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
Standard Capabilies:
Voltage Range 0 to 3000 VDC; 0 to 250 VAC
Frequency 0.2 to 2.0 MHz
Pulse Length/ 10 μs to 10 s
Time Constants Range
Other Specicaons:
Storage Temperature -10 to 70°C
Operang Temperature 5 to 40°C
Intended Use Indoor Use Only
Relave Humidity 20 to 80%
Maximum Altude 2,000 m (6,562 )
Polluon Degree II
Insulaon Category CAT I
Physical Characteriscs:
Overall Dimensions
(45-0207, 47-0203) L x W x D
12.7 x 10.2 x 17.8 cm (5 x 4 x 7 in)
Overall Dimensions
(47-0208, 47-0209) L x W x D
12.7 x 10.2 x 19.0 cm (5 x 4 x 7.5 in)
Weight
1 kg (2.3 lb)
Specifications

7
Safety Stand
5502-002 Rev 2.0 • www.btxonline.com
Ordering Information
Safety Stands
45-0207 Cuvee Safety Stand (Model 630B) 1 Ea
47-0208 Extended Capacity Flatpack Safety Stand 1 Ea
47-0203 AgilePulse MAX Cuvee Safety Stand 1 Ea
47-0209 AgilePulse MAX Extended Capacity Flatpack Safety Stand 1 Ea
47-0610N AgilePulse PLUS Extended Capacity Flatpack Safety Stand 1 Ea
Replacement Parts
45-0213 Replacement Acrylic Safety Stand Cover (for 45-0207 and 47-0203) 1 Ea
45-0215 Metal Replacement Kit (for 45-0207 and 47-0203) 1 Kit
Accessories and Adapters
45-0208 Cuvee Rack (Model 660) 1 Ea
45-0088 F/F adapters, red and black, for 4 mm diameter banana cables and pin ps 1 Kit
45-0217 Banana to banana cables, red and black, 10 length 1 Kit
47-0097 Adapter, AgilePulse PLUS Generator to AgilePulse MAX Stands 1 Ea
Consumables
45-0134 BTX Cuvees Plus, 1 mm gap, 90 µl, Sterile, Gray cap, individually wrapped, with transfer pipees Pkg. of 10
45-0124 BTX Cuvees Plus, 1 mm gap, 90 µl, Sterile, Gray cap, individually wrapped, with transfer pipees Pkg. of 50
45-0140 BTX Cuvees Plus, 1 mm gap, 90 µl, Sterile, Gray cap, bulk wrapped in packages of 100 cuvees per pkg. Pkg. of 100 x 24
45-0135 BTX Cuvees Plus, 2 mm gap, 400 µl, Sterile, Blue cap, individually wrapped, with transfer pipees Pkg. of 10
45-0125 BTX Cuvees Plus, 2 mm gap, 400 µl, Sterile, Blue cap, individually wrapped, with transfer pipees Pkg. of 50
45-0141 BTX Cuvees Plus, 2 mm gap, 90 µl, Sterile, Blue cap, bulk wrapped in packages of 100 cuvees per pkg. Pkg. of 100 x 24
45-0135 BTX Cuvees Plus, 4 mm gap, 800 µl, Sterile, Yellow cap, individually wrapped, with transfer pipees Pkg. of 10
45-0125 BTX Cuvees Plus, 4 mm gap, 800 µl, Sterile, Yellow cap, individually wrapped, with transfer pipees Pkg. of 50
45-0141 BTX Cuvees Plus, 2 mm gap, 800 µl, Sterile, Yellow cap, bulk wrapped in packages of 100 cuvees per pkg. Pkg. of 100 x 24
45-0109 Flatpack Chambers, 1.83 mm gap, 1.5 ml volume Pkg. of 50
45-0110 Flatpack Chambers, 0.56 mm gap, 80 ml volume Pkg. of 50
47-0206 Flatpack Chambers, 4 mm gap, 10 ml volume Pkg. of 10
47-0002 BTXpress Cytoporaon Medium T Low Conducvity Electroporaon Medium, 500 ml bole 1 Ea
45-0801 BTXpress Electroporaon Soluon, 2 ml bole, up to 20 reacons 1 Ea
45-0802 BTXpress Electroporaon Soluon, 5 ml bole, up to 50 reacons 1 Ea
45-0805 BTXpress Electroporaon Soluon, 10 ml bole, up to 100 reacons 1 Ea
45-0803 BTXpress Electroporaon Soluon Kit, 50 reacons in 2 mm gap cuvees 1 Kit
45-0804 BTXpress Electroporaon Soluon Kit, 20 reacons in 4 mm gap cuvees 1 Kit
45-0806 BTXpress Electroporaon Soluon Kit, 100 reacons in 2 mm gap cuvees 1 Kit
45-0807 BTXpress Electroporaon Soluon Kit, 40 reacons in 4 mm gap cuvees 1 Kit

Contact Us
US & Canadian Customers
phone 508.893.8999
fax 508.429.5732
e-mail [email protected]
website www.btxonline.com
International Customers
To locate a distributor
near you, please visit our
website at www.btxonline.com
This manual suits for next models
5
Table of contents