Installation Instructions
Cable fuse box HSW 2209
Intended use
The cable fuse box HSW 2209 is intended to be used in suitable
lighting poles.
The cable fuse box HSW 2209 is designed for the connection of
max. 3 underground cables.
Any other use of this product requires the consultation with the
manufacturer.
Safety instructions
When working on electrical systems, the valid regulations such as
VDE 0100 must be observed. Installation may only be carried out by
qualified personnel or instructed persons in a de-energized state.
Service
In the event of malfunctions or complaints regarding the product,
please contact your sales representative or the manufacturer.
Technical data
Nominal voltage /
-current
400 V / 16 A
Degree of protection
IP54
Protection class
II
Measurements (L x W x H)
290 x 84 x 72 mm
Pole internal diameter
from Ø 89 mm
Door size
80 x 300 mm
Entry field for wire
connection
up to 110 mm
Input connectors
max. 3 cables
5 x 6 - 16 mm²
Mounting in lighting poles
▪Remove housing cover
▪Remove bridge clamp
▪Insert the cable fuse box into open lighting pole and fasten it to
the mounting rail
Bridge clamp strain relief
can be snapped into the lower part
of the housing for easier installation.
For disassembly, the side lugs must
be operated with a slot screwdriver
Adjust input seal
▪Important! With one input cable, always use the existing opening
of the input seal!
▪Break out the inlet seal at the engraved points according to the
number and diameter of the input cables
Connecting the input cable
▪Strip the input cable and remove
the filling material
▪Insert the input cable so that the
outer sheath extends into the
connection compartment
▪Snap on bridge clamp and screw
tight
▪Bending, shortening and stripping
cable conductors to suit
▪Mount or remove the PE/N - N
connection, if present, as
required
▪Insert the cable cores into the U-
profiles according to the terminal
assignment and fasten with the
self-locking sliding clamps (torque
max. 2 Nm)
▪Snap the contact hazard
protection cover on
Connecting the output cable
▪Cut off the nipple of the outlet seal to be used
▪Slide outlet seal over output cable
▪Strip output cable
▪Insert the outlet seal with output cable into the slot of the cable
fuse box
▪Pull the output cable back a little so that the outgoing seal is in full
contact with the cable
▪Shortening and stripping cable conductors to suit
▪Connect the cable cores to the output terminals of the insert
(torque max. 0,8 Nm) or to special components according to the
cable assignment
Assembly
▪Fit housing cover, snap the housing
cover and screw it tight
Special components
▪When special components are used, the respective regulations of
the devices used must be observed
Changing fuse inserts
▪Remove housing cover
▪Remove screw caps and change fuse insert
▪Attention! Do not remove the contact hazard protection cover! It
prevents from the accidental contact with live parts!
Print errors and technical changes excepted (Status: August 2019)
Bevertalstraße 20
D-42499 Hückeswagen
Phone: +49 2192 9166 0
Fax: +49 2192 9166 66
Installation Instructions
Cable fuse box HSW 2209
Intended use
The cable fuse box HSW 2209 is intended to be used in suitable
lighting poles.
The cable fuse box HSW 2209 is designed for the connection of
max. 3 underground cables.
Any other use of this product requires the consultation with the
manufacturer.
Safety instructions
When working on electrical systems, the valid regulations such as
VDE 0100 must be observed. Installation may only be carried out by
qualified personnel or instructed persons in a de-energized state.
Service
In the event of malfunctions or complaints regarding the product,
please contact your sales representative or the manufacturer.
Technical data
Nominal voltage /
-current
400 V / 16 A
Degree of protection
IP54
Protection class
II
Measurements (L x W x H)
290 x 84 x 72 mm
Pole internal diameter
from Ø 89 mm
Door size
80 x 300 mm
Entry field for wire
connection
up to 110 mm
Input connectors
max. 3 cables
5 x 6 - 16 mm²
Mounting in lighting poles
▪Remove housing cover
▪Remove bridge clamp
▪Insert the cable fuse box into open lighting pole and fasten it to
the mounting rail
Bridge clamp strain relief
can be snapped into the lower part
of the housing for easier installation.
For disassembly, the side lugs must
be operated with a slot screwdriver
Adjust input seal
▪Important! With one input cable, always use the existing opening
of the input seal!
▪Break out the inlet seal at the engraved points according to the
number and diameter of the input cables
Connecting the input cable
▪Strip the input cable and remove
the filling material
▪Insert the input cable so that the
outer sheath extends into the
connection compartment
▪Snap on bridge clamp and screw
tight
▪Bending, shortening and stripping
cable conductors to suit
▪Mount or remove the PE/N - N
connection, if present, as
required
▪Insert the cable cores into the U-
profiles according to the terminal
assignment and fasten with the
self-locking sliding clamps (torque
max. 2 Nm)
▪Snap the contact hazard
protection cover on
Connecting the output cable
▪Strip the output cable, shortening and stripping cores
▪Insert the output cable through the cable gland
▪Screw the pressure nut together until the seal set between nut and
cable forms a small bead
▪Connect the cable cores to the output terminals of the insert
(torque max. 0,8 Nm) or to special components according to the
cable assignment
Assembly
▪Fit housing cover, snap the housing
cover and screw it tight
Special components
▪When special components are used, the respective regulations of
the devices used must be observed
Changing fuse inserts
▪Remove housing cover
▪Remove screw caps and change fuse insert
▪Attention! Do not remove the contact hazard protection cover! It
prevents from the accidental contact with live parts!
Print errors and technical changes excepted (Status: August 2019)

Popular Enclosure manuals by other brands

Stardom U2F-B32 Quick setup guide

Stardom

Stardom U2F-B32 Quick setup guide

Crestron BB-3100L installation guide

Crestron

Crestron BB-3100L installation guide

Onnto SATA to USB 2.0 3.5" HDD Enclosure Kit user manual

Onnto

Onnto SATA to USB 2.0 3.5" HDD Enclosure Kit user manual

Hoffman Proline Guide

Hoffman

Hoffman Proline Guide

Safe-t-Cover 1000S-AL Assembly instructions

Safe-t-Cover

Safe-t-Cover 1000S-AL Assembly instructions

Diablotek CP6004BKW user manual

Diablotek

Diablotek CP6004BKW user manual

Dell PowerVault MD1120 Getting started guide

Dell

Dell PowerVault MD1120 Getting started guide

Pulsar AWO 360 Assembly instructions

Pulsar

Pulsar AWO 360 Assembly instructions

Nexto Di eXtreme QS-2700 quick start guide

Nexto Di

Nexto Di eXtreme QS-2700 quick start guide

COUGAR MG140 RGB Assembly instructions

COUGAR

COUGAR MG140 RGB Assembly instructions

Genz Benz TAC EX-1502 owner's manual

Genz Benz

Genz Benz TAC EX-1502 owner's manual

ENERMAX Brick EB308 user manual

ENERMAX

ENERMAX Brick EB308 user manual

Chenbro SK31101 Series user manual

Chenbro

Chenbro SK31101 Series user manual

Bopla INTERZOLL 6HU Assembly instruction

Bopla

Bopla INTERZOLL 6HU Assembly instruction

SWR Custom Pro Specialist owner's manual

SWR

SWR Custom Pro Specialist owner's manual

Netstor NA211TB Quick installation guide

Netstor

Netstor NA211TB Quick installation guide

Bticino 375006 manual

Bticino

Bticino 375006 manual

Pulsar ARAD3S installation guide

Pulsar

Pulsar ARAD3S installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.