INNO INNO-Flex FV6-Central User manual

INNO-FLEX-Distribution-Box
© INNO-Products GmbH - Print-No. 1031.2.GB 01.2009 as of INNO-Flex-distribution is subject to change. Illustrations and specifications are subject 1
1. Delivery:
- Art.No. 2.022: FV6-Central
1 INNO-Flex base with 6 Flex-duct connections 75
1 INNO-Flex connection DN 180 with reduction to DN 150
- Art.No. 2.023: FV12-Flat
2 INNO-Flex base with 6 Flex-duct connections 75
1 INNO-Flex connection DN 180 with reduction to DN 150
- Art.No. 2.024: FV12-Central
2 INNO-Flex base with 6 Flex-duct connections 75
2 INNO-Flex connection DN 180 with reduction to DN 150
-Art.No. 2.025: FV18-Flat
3 Inno-Flex base with 6 Flex-duct connections 75
1 INNO-Flex connection DN 180 with reduction to DN 150
- Art.No. 2.026: FV18-Central
3 Inno-Flex base with 6 Flex-duct connections 75
3 Inno-Flex connection DN 180 with reduction to DN 150
- A recent installation, operation and maintenance manual
2.1 Field of application and use:
The INNO-Flex-distribution system was developed specifical-
ly for the connection of pipes and ISODuct INNO-Flex hose
and used for the controlled ventilation of buildings, flats, etc.
2.2 Improper operation:
- Use fat-containing waste air, explosive gases, dust-laden
air or adhesive aerosols
- Outdoor installation
- Connection of cooker hoods to the ventilation system
2.3 Safety hints:
- Always follow the safety rules on this line. Failure to comply
can result in personal injury or damage to the device.
- Keep these instructions should be in the vicinity of the
device.
- Put the distribution system only in accordance with the
above-described purpose.
- Let yourself introduce into the system after the installation
from your installer.
- Installation and repair work must be carried out only by
authorized specialist personnel.
- Place the plant out of service immediately if you notice any
damage or defects are a risk to persons or property.
Further use should be avoided until full restoration!
- Make sure the distributor only grown with all the connecting
pipes.
- The distributor must only be operated under the framework
of the systems planning of the calculations.
2.4 Warranty and Product Liability:
For each delivery are subject to our "Terms and Conditions"
in its current version. The distributor has a 2-year manufactu-
rer's warranty from commissioning, starting no later than two
months from delivery date (delivery INNO-Products GmbH to
the installer). The warranty is limited to the pure material
replacement and does not include the service.
The guarantee applies only on proof of an executed operati-
on and regular maintenance performed in accordance with
our rules, by one of our authorized installer.
Warranty claims can be material or construc-tion made errors
of law only.
If you have any complaints, the unit may not be removed wit-
hout our written consent.
A warranty on parts will be granted only if these were sup-
plied by us and installed by an authorized installer.
The warranty is void:
(a) if the device is operated during the construction phase
and is very dirty.
(b) if no original spare parts.
(c) if unauthorized changes are made to the plant.
(d) if the device is exposed to aggressive substances.
(e) if the device is operated with aggressive air.
(f) automatically after a period of 2 years.
Further on, the company INNO-Products not liable for dama-
ges that are attributable to:
(g) failure to follow safety, operating and maintenance
requirements of this technical documentation.
(h) the use of non-INNO Products geliefer-ten materials.
The responsibility lies solely with the installing operation..
(i) normal wear and tear.
3.1 Cutting and broken edges on the body:
XCutting edge revision cover
YCutting edge slot base
ZCutting edge INNO-Flex duct connection
[Cutting edge content, body
\Drive-in cover for pipe connection
3.2 Cutting edge on the pipe socket:
]Cutting edge as connectors for central distribution box
^Cutting edge for ISODuct pipe DN 180
Instruction Manual
X
^
]
\
[
Z
Z
Y

4. Connecting pipe stub on INNO-Flex-Distribution box:
Fold in the cover \with a medium-strong hammer hit
Remove the broken lid \
Place the connecting pieces in the free opening until it clicks
into place.
Note: Cut the pipe before the desired length: DN 180 or
connectors! (See point 5)
Note: The plug-in edge is provided before the final connecti-
on to a peripheral Silikonwulst to ensure air tightness in
accordance with german DIN EN 1610..
5. Shortening of the connector housing:
Shorten a connecting pipe-to-edge ^to establish a duct
connection for ISO-Duct DN 180.
Cut the connection pipe to edge ]
to produce a connector for central distribution box.
6. Preparing a revision of opening:
Disconnect the inspection cover on the edge of Xwith a
jigsaw cleanly. The sawed-off part is the revision cover dar.
Disconnect the adapter to edge from Yin the same way.
The cut piece is waste and is no longer used.
Instruction Manual
© INNO-Products GmbH - Print-No. 1031.2.GB 01.2009 as of INNO-Flex-distribution is subject to change. Illustrations and specifications are subject 2
\
\
]
^
INNO-FLEX-Distribution-Box

Remove any burrs with sandpaper.
6. Producing a Flat-/Etagen-Distribution box with 12 or
18 INNO-Flex-Duct connections:
a) Open the main body V1 at the cutting edge Xand Y,
as discribed under 6.
b) Open the body at the cutting edge of V2 [.
The two main body V1 and V2 can now slide into each other.
method of producing a Flat-/Etagen-Distribution box with 18
ports, analog to the aforementioned steps.
A production of distributors with more than 18 ports is not
recommended, since the required air flow can not be guaran-
teed.
Note: The plug-in edge is provided before the final connecti-
on to a peripheral Silikonwulst to ensure air tightness in
accordance with german DIN EN 1610.
7. Manufacture of central distribution box
with 12 or 18 INNO-Flex-Duct connections:
Flip the lid \with a medium-strong hammer hit each on the
bottom and the top of the connected body, as described
under 4.
Shorten a connecting pipe-to-edge ^
to create a connector for central distribution.
Plug the connecting pieces in a main body and the second
Body to this connection.
Note: The plug-in edge is provided before the final connecti-
on to a peripheral Silikonwulst to ensure air tightness in
accordance with german DIN EN 1610.
method for producing a central manifold with 18 ports, ana-
log to the aforementioned steps.
A production of distributors with more than 18 ports is not
recommended, since the required air flow can not be guaran-
teed.
For the production of through distributors refer to the page
where you want to take the pipe on the lid \and install an
additional connecting pieces.
Instruction Manual
© INNO-Products GmbH - Print-No. 1031.2.GB 01.2009 as of INNO-Flex-distribution is subject to change. Illustrations and specifications are subject 3
Body V1 Body V2
Connector
\
]
INNO-FLEX-Distribution-Box

8. Opening the ports for INNO-Flex hose DN 75:
Open to any distribution base, the terminal port Zin the
required number.
Note: 1 piece is perforated for production reasons, these
must always be connected with, or hermetically sealed.
Remove any burrs with sandpaper.
Slide the INNO-Flex hose DN75 with the prescribed and pro-
perly fitted for poetry in the open socket connection to this is
fixed.
When embedding of the manifold, the hose connections
are fixed in position using cold shrinking tape.
Do the same for all other connections.
When using INNO-Flex hose DN 63, use the reductions
RED75/63 (Art.No. 2.015) with the respective seals DN 75
and DN 63.
9. Mounting of the distributor:
The distributor can be attached to the ceiling with floor
screws M8, which is 2 passes provided to the left and right of
the distributors.
Note: When moving the pipe connections with central distri-
bution, such as by turning the second Manifold at 180° were
present, not more about each other passages. The attach-
ment of the lower manifold is then punched tape or similar
means produce.
If you have any problems with your ventilation system, you
should first contact to the specialist installer who has made
the installation of the system. If this is not possible, please
do not hesitate even to us:
INNO-Products GmbH Deutschland
Dorfgütingen 52
DE-91555 Feuchtwangen
INNO-Products GmbH Switzerland
Münchensteinerstr.43
CH-4052 Basel
fon: +49 (0) 98 52 - 61 38 - 08
fax: +49 (0) 98 52 - 61 38 - 10
mail: [email protected]
www.inno-products.de
This product is in its type, design and functionality for utility
model protection (Nr. 20 2006 013 503 0).
Instruction Manual
© INNO-Products GmbH - Print-No. 1031.2.GB 01.2009 as of INNO-Flex-distribution is subject to change. Illustrations and specifications are subject 4
Z
INNO-FLEX-Distribution-Box
This manual suits for next models
9
Popular Fan manuals by other brands

Montigo
Montigo LDVPV47 Installation & maintenance manual

Monte Carlo Fan Company
Monte Carlo Fan Company MC5B241 Owner's guide and installation manual

Maico
Maico ERM 18 Ex e operating instructions

Partel
Partel LUNOS ALD installation manual

Rosenberg
Rosenberg DR-Ex Series operating instructions

PureMate
PureMate PM 710 instruction manual