IR2568 Concealed WC Cistern with Infra Red Flush
Dimensions
Technical Specification
Operating water pressure range: 1 to 8 bar (recommended
max 5 bar).
Power supply: 6V lithium battery mod. CRP-2.
The water flush is activated by a hand wave 5 to 6 cm
Operating
away from the infra red sensor.
Auto-flush: every 24 hours from the last flush.
Installation
Before commencing the installation ensure the wall on
which the cistern is to be mounted is structurally suitable.
Install the cistern directly above the toilet pan and using the
most suitable flush pipe connect to the toilet.
Connect the water supply to the cistern, a service valve
must be installed in the supply pipe should future
maintenance be required.
Do not turn on the water supply at this time.
Drill a hole in the concealing panel 40 to 45mm in
diameter for the infra red sensor.
The distance from the sensor to the solenoid valve must be
less than 900mm.
Introduction
This installation guide has been produced for the IR2568
WC cistern and infra red flush. These instructions cover the
installation, operation and maintenance.
The cistern and flush are intended for concealed installation
behind a panel.
Please read the enclosed instructions before commencing
the installation of this product, please note;
We recommend that the installation of any Inta product is
carried out by an approved installer.
Check Content
Before commencing remove all components from the
packaging and check each component with the contents
list.
Ensure all parts are present, before discarding any
packaging. If any parts are missing, do not attempt to
install your Inta cistern and flush until the missing parts
have been obtained.
Components
Ø55
Ø40-45
Max 65
Battery
Box
440 38
315
400
130
55
Ø50 8
2
Item Component
1 Cistern with Cover
2 Flush Valve - installed in cistern
3 Inlet Flow Valve - installed in cistern
4 Solenoid Valve
5 Infra Red Sensor
6 IP65 Battery and Battery Box
7 Perspex Tube
8 Flush Pipe
Intatec Limited, Airfield Industrial Estate, Hixon, Staffordshire, ST18 0PF
© Intatec Ltd. 2014 12-05-14
Tel:01889 272 180 Fax:01889 272 181 email:[email protected] web:www.intatec.co.uk
IR2568 Concealed WC Cistern with Infra Red Flush
Maintenance
Cleaning the Sensor
The darkened window which protects the sensor must
always be clean in order to allow its correct operation.
Do not use abrasive material to avoid damaging the plastic
surface.
Battery Replacement
When the battery is exhausted, the LED flashes
continuously and the solenoid valve stops in the closing
position.
Turn off the water supply to the cistern.
Pull apart the two halves of the connector to disconnect the
battery
Remove the exhausted battery and replace it with a new
one of the same type (CRP-2).
Dispose of the exhausted battery in an appropriate
manner.
Warranty
The cistern and flush are covered by a 1 year warranty for
any fault due to defects in material, design or
workmanship.
The warranty does not cover damage caused by: incorrect
installation, negligence in maintenance and use, acts of
vandalism, contact with abrasive or corrosive chemicals
and unsuitable cleaning instruments.
Also the presence of any dissolved compound in the water
(limestone, halogen compounds, acids, etc.) leads to a loss
of the warranty.
Connect the battery to the sensor and sensor to the solenoid
valve.
Turn on the water supply and check for signs of leakage,
allow the cistern to fill and check the sensor for correct
operation.
Failure to observe these installation instructions will
invalidate the product warranty.
Ensure the sensor cannot be affected by any external
sources such as a mirror which may create nuisance
operation of the product.
The battery box is attached to the retaining bracket for the
sensor as shown.
Installation Continued
Connect the perspex pipe (7) to the solenoid valve (4).
Remove the cover from the cistern, slot the solenoid valve
into the side of the cistern as shown.
Connect the perspex pipe from the solenoid valve to the
flush valve installed within the cistern, replace the cover.
Battery
Box
56
7 4

Other Inta Kitchen & Bath Fixture manuals

Inta IR500CP User manual

Inta

Inta IR500CP User manual

Inta IR180CP User manual

Inta

Inta IR180CP User manual

Inta NC230CP User manual

Inta

Inta NC230CP User manual

Inta Mio MM40014CP User manual

Inta

Inta Mio MM40014CP User manual

Popular Kitchen & Bath Fixture manuals by other brands

Glacier bay 67070-3301 Use and care guide

Glacier bay

Glacier bay 67070-3301 Use and care guide

DURAVIT C.1 Series Instructions for mounting and use

DURAVIT

DURAVIT C.1 Series Instructions for mounting and use

Moen CA87094SRS manual

Moen

Moen CA87094SRS manual

Delabie TEMPOSOFT installation instructions

Delabie

Delabie TEMPOSOFT installation instructions

Sanela SLUN 16 Mounting instructions

Sanela

Sanela SLUN 16 Mounting instructions

VALVEX SOLO 2452880 Assembly and operation instructions

VALVEX

VALVEX SOLO 2452880 Assembly and operation instructions

baliv KV-4050 manual

baliv

baliv KV-4050 manual

Sani-Lav 2004 operating manual

Sani-Lav

Sani-Lav 2004 operating manual

Speakman SBS-2142 installation instructions

Speakman

Speakman SBS-2142 installation instructions

JADO Classic Victorian 865/708 Series installation instructions

JADO

JADO Classic Victorian 865/708 Series installation instructions

Hans Grohe AXOR Montreux 16535 Series Instructions for use and assembly instructions

Hans Grohe

Hans Grohe AXOR Montreux 16535 Series Instructions for use and assembly instructions

Brizo VUELO RP64473 quick start guide

Brizo

Brizo VUELO RP64473 quick start guide

Kohler LOURE K-98454T-B-CP installation instructions

Kohler

Kohler LOURE K-98454T-B-CP installation instructions

Oras 272100 Installation and maintenance guide

Oras

Oras 272100 Installation and maintenance guide

Sanela SLZM 13W Mounting instructions

Sanela

Sanela SLZM 13W Mounting instructions

VIGO Matte Stone VG04001 manual

VIGO

VIGO Matte Stone VG04001 manual

InSinkErator H/HC3300 Installation, care & use

InSinkErator

InSinkErator H/HC3300 Installation, care & use

Delinia MAXINE instruction manual

Delinia

Delinia MAXINE instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.