ITC Audio TI-60CT User manual

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
MIXER AMPLIFIER WITH CD+TUNER
TI-240CT
TI-120CT
TI-60CT
OPERATION MANUAL
AUDIOAUDIO
PUBLIC ADDRESS SYSTEM
on
off
AUDIOAUDIO
TI-60CT
MIXER AMPLIFIER WITH CD+TUNER 60W
AUX 1
0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 -5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
0
1
2
3
456
7
8
9
10
-5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
MIC 1
MIC 1 MIC 2 MIC 3 CD TUNER BASS TREBLE MASTER
BAND AUTO/MA DOWN UP
TUNING
246810 12
OUTPUT LEVEL
POWER PORT
PREVIOUS NEXTSTOP
PLAY
OPEN/CLOSE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5
CHIME

TABLE OF CONTENTS
TI-60CT/TI-120CT/TI-240CT 2
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel ............................................................................................................ 6
4.2 Rear Panel..............................................................................................................7
5. CONNECTIONS
5.1. Speaker Connections .............................................................................................8
5.2. XLR Connections ................................................................................................. 8
6. APPLICATIONS .......................................................................................................9
..............................................................................................10
.....................................................................................................10
9. BLOCK DIAGRAM...................................................................................................11
10.SPECIFICATIONS ................................................................................................12
11.DIMENSIONAL DIAGRAM ..................................................................................13
7. TUNER OPERATION
8. CD OPERATION
V1.2-2009-06-03

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3TI-60CT/TI-120CT/TI-240CT
1. SAFETY PRECAUTIONS

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
ITC
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
4
TI-60CT/TI-120CT/TI-240CT
1. SAFETY PRECAUTIONS

5
3. FEATURES
The CD + Tuner Mixer Amplifier series provide an integrated sound system for background music, paging
and fire emergency alarm applications, the multi choices of power wattages from 60W to 120W and 240W can
provide an ideal public address solution from small to big places such us mosques, schools, hotels and factories
to train stadium and air stations.
2. GENERAL DESCRIPTION
1. Rated outputs from 60W to 120W and 240W.
2. 100V/70V line transformer-isolated speaker outputs, low impedance 4-16 ohms speaker outputs.
3. Ideal integrated sound solution of BGM and paging.
4. Built-in CD player and AM/FM tuner and remote control .
5. VFD English display.
6. CD song individual cycle and all cycle broadcasting modes.
7. AM/FM each 100 channels memory storage.
8. Tuner manual or automatic search .
9. Two balanced line inputs and three balanced microphone inputs.
10. One stereo aux input and one amp input.
11. One EMC input with priority over all other inputs except MIC 1.
12. One pre output and two line outputs.
13. AUX, MIC, CD, Tuner, Bass, Treble and Master volume control.
14. MIC 1 mute level control.
15. Power and protection indicators and 6 output level meters.
TI-60CT/TI-120CT/TI-240CT

on
off
AUDIOAUDIO
TI-60CT
MIXER AMPLIFIER WITH CD+TUNER 120W
AUX 1
0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 -5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
0
1
2
3
456
7
8
9
10
-5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
MIC 1
MIC 1 MIC 2 MIC 3 CD TUNER BASS TREBLE MASTER
BAND AUTO/MA DOWN UP
TUNING
246810 12
OUTPUT LEVEL
POWER PORT
PREVIOUS NEXTSTOP
PLAY
OPEN/CLOSE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5
CHIME
4.1 FRONT PANEL
6
1. PLAY
Play button (CD)
2. POWER SWITCH
On top of the opening Power
Press the end, power shut down
3. STOP
Stop button (CD)
4. PREVIOUS
Previous button (CD)
5. AUX1
AUX volume control (AUX 1)
6. NEXT
Next button (CD)
7. MIC1 \ MIC2 \ MIC3
MIC volume control (MIC1/MIC2/MIC3)
8. CD
CD volume control
9. TUNER
Tuner volume control
10.BASS
Adjust bass response. Rotate clockwise to increase
bass output and anticlockwise to reduce it.
11.TREBLE
Adjust treble response. Rotate clockwise to increase
treble output and anticlockwise to reduce it.
12.BAND
AM/FM Band select button (Tuner)
13.MASTER
Master volume control All input level control
4. NOMENCLATURE AND FUNCTIONS
TI-60CT/TI-120CT/TI-240CT
1 2 3 4 5 6 78 9 10 11 1312 14 15 16 17
18
19
2021222324252627
14.AUTO/MA
Auto/Manual band search button (Tuner)
15.DOWN
Down search channel (Tuner)
16.MIC1
MIC1 input 6.3 Microphone jack input
17.UP
UP search channel (Tuner)
18.TUNER SCREEN
Display the working state of tuner
19.OUTPUT LEVEL
Level meters 6 output level indicators
20.PROT
Protection indicator
21.POWER
Power indicator
22.(1~5) ZONE
(1~5) zone indicator
23.(1~5) ZONE
(1~5) zone button
24.CHIME
Chime indicator
25.CHIME
Chime button
26.OPEN/CLOSE
Open/Close button (CD)
27.GIVE ON
28.CD SCREEN
Display the working state of CD
28

29 31 3230 33 34 35 36 37 38
39404142
4344
4547
OUTPUT
ZONE 2
COM 100V
ZONE 3
COM 100V
ZONE 1
COM 100V
COM 4-16 70V
MIC2 MIC3
MUTE LINE 1 LINE 2
ANTENNA
LOOP ANTENNA
AM
GND
FM 75
ZONE 4
COM 100V
ZONE 5
COM 100V
100V
OFF
ON
PHANTOM
+48V
EMC INPUT
AUX 1 PRE OUT
AMP IN
OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
PRIORITY CHIME
VOL.
PHANTOM
+48V
OFF
ON
CHIME
2 TONE
4 TONE
~230V 50HzT2AL250V
46
NOMENCLATUREAND FUCTIONSNOMENCLATUREAND FUCTIONS
7TI-60CT/TI-120CT/TI-240CT
4.2 REAR PANEL
29.(1~5) ZONE OUTPUT TERMINAL (100V)
Connecting speakers
30.MIC2 \ MIC3
MIC balanced inputs
31.MUTE
Mute Microphone 1 mute level control
32. \
Line Unbalanced inputs
33.EMC
EMC Input Fire alarm signal input
34.AUX1
Auxiliary input jack, Non-equilibrium of connecting
peripherals signal
35.AMP IN
Amplifier Input
36.OUT
Line output, Non-equilibrium type, the output of
all input signals.
LINE1 LINE2
37.PRE OUT
PRE-Amplifier Output
38.COOLING FANS
39.~230V/50Hz AC POWER INPUT
40.AC FUSE
41.CHIME VOL.
Chime volume control
42.PRIORITY
Short-circuit protection
43.CHIME(2 Tone\4 Tone)
Chime(2 Tone\4 Tone) volume Control
44.AM-BAND ANTENNA
45.FM BAND 75 OHM ANTENNA
46.+48V PHANTOM SWITCHES
47.SPEAKER TERMINALS
Connectors for 4-16 ohms or 70V and 100V
speaker

70V 100V
COM 4-16 70V 100V
COM 4-16
(TI-60CT)
(TI-120CT)
(TI-240CT)
167
83
41
100V LINE
70V 100V
COM 4-16
(TI-60CT)
(TI-120CT)
(TI-240CT)
81
41
20
70V LINE
5.1 SPEAKER CONNECTIONS
5.2 XLR CONNECTIONS
TI-60CT/TI-120CT/TI-240CT 8
4-16
COM 100V COM 100V COM 100V COM 100V
COM 100V
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5
100V LINE 100V LINE100V LINE100V LINE100V LINE
(TI-60CT)
(TI-120CT)
(TI-240CT)
167
83
41
5. CONNECTIONS
70V/

6. APPLICATIONS
MIC 3
MIC 2
+ ALARM IN -
ALARM OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
~230V 50Hz
T1AL250V
EMERGENCY PANEL
~230V 50Hz
T1AL250V
AUDIO
OUT
R
L
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
AUDIO SOURCES
~230V 50Hz
T1AL250V
AUDIO
OUT
R
L
COM
ADRESS TAG
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
AUDIO SOURCES
LINK
INPUTS
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESSSYSTEM
SERIAL NO:
XLR BAL
1-GND
2-HOT+
3-COLD
1
2
3
12
3
OUTPUTS
INPUTS
~ 230V 50Hz
T5AL250V
POWER AMPLIFIER
SPEAKERS
OUTPUT
ZONE 2
COM 100V
ZONE 3
COM 100V
ZONE 1
COM 100V
COM 4-16 70V
MIC2 MIC3
MUTE LINE 1 LINE 2
ANTENNA
LOOP ANTENNA
AM
GND
FM 75
ZONE 4
COM 100V
ZONE 5
COM 100V
100V
OFF
ON
PHANTOM
+48V
EMC INPUT
AUX 1 PRE OUT
AMP IN
OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
PRIORITY CHIME
VOL.
PHANTOM
+48V
OFF
ON
CHIME
2 TONE
4 TONE
~230V 50HzT2AL250V
AM ANTENNA
FM ANTENNA
SPEAKERS
MIC LINE
COM
ADRESS TAG
9TI-60CT/TI-120CT/TI-240CT

FM 104.70
AM
FM
STEREO MUTE AM/FM MEMORY AUTO
MHz
KHZ 02 mSEC
MIN
cHdB
CINEMA DSP
FM 104.70
AM
FM
STEREO MUTE AM/FM MEMORY AUTO
MHz
KHZ 02 mSEC
MIN
cHdB
CINEMA DSP
FM 104.70
AM
FM
STEREO MUTE AM/FM MEMORY AUTO
MHz
KHZ 02 mSEC
MIN
cHdB
CINEMA DSP
FLUORESCENCE DISPLAY
=TUNER OPERATING
1. Open power supply switch on, fluorescence
show last time close employment state.
Stereo show Auto tune show
Wave band show
Frequency show
Frequency unit show
Wave band show Frequency show
2. Select broadcast wave band
As if show an't want to wave band, invite
press Wave band key stoke accept of wave
band, per Press once, give switch fm/am.
3. Select broadcasting station means
Auto tune show occasionally auto illumine
Per press once auto /
Manual tune select key
(auto/ma)give switch
4. Select broadcast broadcasting station
Press key up direction high end frequ-
ency search, press key down direction
low end frequency search.
Auto tune occasionally: Auto take over one
Broadcasting station
Manual tune occasionally: Repeat press(or
Persist press)up to select broadcasting station
FM 104.70
AM
FM
STEREO MUTE AM/FM MEMORY AUTO
MHz
KHZ 02 mSEC
MIN
cHdB
CINEMA DSP
Auto tune show occasionally auto illumine
7. TUNER OPERATION
=CD OPERATING
1. Press "power" switch on power supply
2. Button function
6. CD Diskette Play
1 .Placement CD diskette read back enter
firstly catalog choice menus and play firstly
song use pervious and next key can elect
demand song.
2 . Play course press key stop, menu backtrack
catalog choice menus Using previous and n-
ext key choose demand song press key play
come into homologous catalog choice menus,
a new press key play, carry out like 1 of play
function.
8. CD OPERATION
10
3. Dish placements tray up
4. Press key "open/close" tray close start read
PLAY / PAUSE
STOP / RETURN
PREVIOUS
NEXT
5. Play diskette
TI-60CT/TI-120CT/TI-240CT

MUTE
MUTE
MIC2
MIC3
LINE1
LINE2
AUX1
EMC
CD PLAYING
TUNER
DISPLAY/CONTROL
DISPLAY/CONTROL
PROTECT
9. BLOCK DIAGRAM
11 TI-60CT/TI-120CT/TI-240CT
CHIME

MODEL
RATED POWER OUTPUT
SPEAKER OUTPUTS
PROTECTION
TONE
INPUT
FREQUENCY RESPONSE
S/N RATIO
T.H.D
CROSSTALK
MUTING FUNCTION
CONTROLS
INDICATORS
MIXER AMPLIFIERMIXER AMPLIFIER
TUNERTUNER
TI-120CT
120W
4~16 ,70V/100V
MIC 1 2 3 5mv/600 Ohms,Balanced
AUX 1 250mV/15KOhms, Unbalanced
EMC 250mV/15KOhms, Unbalanced
Bass: 10dB at 100Hz
Treble: 10dB at 10KHz
50Hz~15KHz
MIC 1 2 3 66dB;AUX 1 80dB
Less than 1% at 1KHz,1/3 rated power
MIC : 80dB;AUX 85dB
MIC 1 over other input signals with 0~30dB
attenuation
EMC ove all inputs except MIC 1
Individual gain controls, power switch
Power LED,LED level meter,protect
AC fuse, short-circuit and high temperature
87-108MHz 522-1611kHz
=20uV =6.0mV/m
=40dB =36dB
FREQUENCY RESPONSE
SENSITIVITY
SIGNAL / NOISE RATIO
S/N
DIMENSION(mm)
NET WEIGHT
GROSS WEIGHT
>80dB
484X399X132
FM
FM
FM
AM
AM
AM
DISTORTION
POWER CONSUMPTION
FREQUENCY RESPONSE
POWER REQUIREMENTS
200W
10. SPECIFICATIONS
TI-60CT TI-240CT
60W 240W
<0.1%
120W 350W
CD PLAYCD PLAY
ELSEELSE
14.7Kg
16.4Kg
12
20Hz-20KHz(+1/-3dB)
~230V/50Hz
-
+
-
+
TI-60CT/TI-120CT/TI-240CT
13.1Kg
14.8Kg
17.9Kg
18.8Kg

128
128
399
390
132
148
436
444
100
Over
100
Over
Over
100
UNIT :mm
11. DIMENSIONAL DIAGRAM
UNIT :mm
on
off
AUDIOAUDIO
TI-60CT
MIXER AMPLIFIER WITH CD+TUNER 120W
AUX 1
0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 -5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
0
1
2
3
456
7
8
9
10
-5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
MIC 1
MIC 1 MIC 2 MIC 3 CD TUNER BASS TREBLE MASTER
BAND AUTO/MA DOWN UP
TUNING
246810 12
OUTPUT LEVEL
POWER PORT
PREVIOUS NEXTSTOP
PLAY
OPEN/CLOSE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5
CHIME
OUTPUT
ZONE 2
COM 100V
ZONE 3
COM 100V
ZONE 1
COM 100V
COM 4-16 70V
MIC2 MIC3
MUTE LINE 1 LINE 2
ANTENNA
LOOP ANTENNA
AM
GND
FM 75
ZONE 4
COM 100V
ZONE 5
COM 100V
100V
OFF
ON
PHANTOM
+48V
EMC INPUT
AUX 1 PRE OUT
AMP IN
OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
PRIORITY CHIME
VOL.
PHANTOM
+48V
OFF
ON
CHIME
2 TONE
4 TONE
~230V 50HzT2AL250V
on
off
AUDIOAUDIO
TI-60CT
MIXER AMPLIFIER WITH CD+TUNER 120W
AUX 1
0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10 -5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
0
1
2
3
456
7
8
9
10
-5
0
-1
-2
-3
-4
+1
+2
+3
+4
+5
MIC 1
MIC 1 MIC 2 MIC 3 CD TUNER B ASS TREBLE MASTER
BAND AUTO/MA DOWN UP
TUNING
246810 12
OUTPUT LEVEL
POWER PORT
PREVIOUS NEXTSTOP
PLAY
OPEN/CLOSE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5
CHIME
13 TI-60CT/TI-120CT/TI-240CT

AUDIOAUDIO
Guangzhou ITC Electronic Technology Limited
Http://www.itc-pa.com.cn
PUBLIC ADDRESS SYSTEM
2009-06 Version1.2
This manual suits for next models
2
Table of contents