Foreword
Dear customer,
In choosing a ScreenMotion Basic model, you have decided to acquire a technically advanced and powerful
motor-driven guide column. Your ScreenMotion Basic has been manufactured inhouse with the utmost care and
precision and has passed numerous quality and safety checks to ensure trouble-free and safe operation. You can
significantly contribute to your long-term satisfaction with your ScreenMotion Basic model.
Important Safety Information
1. Assembly and operation of the motor-driven guide column must be in accordance with these assembly
instructions – otherwise there is a risk of injury!
2. The guide column is solely intended to serve as entertainment solution for living room, bedroom and
conference room furniture in accordance with the weights and measurements given in these instructions. Any
usage other than that mentioned above is inappropriate; themanufacturer disclaims liability for any resulting
damages. In such cases all risk iscarried by the user.
3. Before any downward movement the space in the furniture compartment must be checked. There must not be
any persons, animals or objects in the compartment.
4. The column must be abled to move into bottom position at all times. When mounting the TV set and running
the cables it is important to ensure that these do not interfere with reaching the bottom position.
5. Compliant with emission class 1 for particleboards. No emission of harmful substances pursuant to Safety Data
Sheet; no emission of harmful substances in harmful concentrations.
6. The intended operation of the device implies compliance with the assembly instructions stipulated by the
manufacturer.
7. Please also take into account the general legal and other regulations and legal provisions that are applicable –
including those that apply in the operator’s country - as well as the applicable environmental protection
regulations. The regulations of trade associations or other supervisory authorities that are in force locally must
always be observed!
8. The manufacturer cannot be held responsible for any losses or damage resulting from unauthorised
modifications to the ScreenMotion Basic.
9. Never open the control unit housing! As a result of unauthorised opening of the housing and improper repairs
dangers can arise for the user and the guarantee claim expires.
10. Repairs may only be carried out by personnel working for or licensed by the manufacturer!
11. Do not allow any liquid to penetrate the inside of the control unit or the lift column. This could lead to short
circuiting and destruction of control elements. Controls may only be operated in enclosed areas. Do not use
in humid environments.
12. The control unit and lift column may only be used for the purposes outlined in these assembly instructions.
13. Please first check whether cable or housing are damaged. In this case do not operate the device but have it
replaced by your service partner.
14. The control unit is only suitable for operation in enclosed and dry living and office rooms. It may not be used
outdoors.
15. Do not connect electric devices with a power consumption of over 800 watts to the live outlet (socket).
16. Do not connect electric heating devices, fan heaters, radiators or power tools such as drills, jigsaws or similar
devices to the live outlet (socket).
17. The control unit may only be used for the operation of Kesseböhmer drives.
18. Keep other objects away to eliminate any danger of jamming or crushing them.
19. Function of safety sensor:
- The sensor is not activated until one second after the start of any movement.
- After the safety sensor is activated a pause of ca. 5 sec. needs to be observed until the swaying of the
fitting stops.

889012120 0000 Page 16 of 27
Provided the above guidelines are adhered to, you will enjoy many years of satisfaction from your ScreenMotion
Basic. For any further enquiries please do not hesitate tocontact us.
Important notice for Start-up operation
- The socket for connection with the mains must be installedby a licensed electrician in order to avoid any hazard
to persons or objects.
- Make sure that the socket is accessible at all times.
- The assembly site should be dry, dust-free and not in direct sunlight.
-The ambient temperature for operation of the control unit must not go below +5°C or above +35°C.
-For these reasons do not assemble the control unit:
-above or in front of heat sources (e. g. heaters),
- in places exposed to direct sunlight,
- behind curtains,
- in small, unaired, damp rooms,
- on or near easily flammable materials or
- near high frequency equipment (e. g. transmitters, radiationequipment or similar devices).
- If the device emits smoke, please unplug the power cord.
- The socket for connecting the motors and the IR-receiver must not be covered.
- Make sure the connecting cables are not kinked, pulled or mechanically strained
-For protection against power surges, e.g. during thunderstorms, the installation of surge protection is
recommended.
- Ask your electrician for advice.

889012120 0000 Page 17 of 27
SME for installation in furniture
!
A minimum all-round distance of 25 mm
between built-in screen and furniture or
other structural objects must be maintained.
4
The bottom edge of the screen may
not project more than 4 mm above
the top edge of the furniture.
Appropriate mount in the furniture.
Stability in accordance with
DIN Fb 147.
!
<
Versions
After initial operation adjust the screen
support by means of the fastening
screws (1) and ensure that it runs
parallel to the furniture.
1
1
Danger of collision
In the bottommost 80 mm the sensor
is inactive. (This area has to remain free
of all objects)
!
1
1
!

738 / 778 / 928
680 /720 /870
700
500
Free-standing SME with ground plate
Should the ground plate 700x500 mm, which is available as an
accessory, not be used, a plate of the same size having a minimum
weight of 22 kg must be mounted.
Attention:
Set screws must be adjusted on a plane surface.
Item no for the ground plate: 889010903
889012120 0000 Page 18 of 27
!
1
1
Danger of collision
In the bottommost 25 mm
the sensor is inactive.
(This area has to remain free of all objects.)
!
(30) 708 / 748 / 898

Accessories
A
20
A
M6x16
Glue piece
M6x16
max. 15 Nm
fleece tape
piece of felt
SW 4
Glue piece of felt onto the column.
Insert support arms into the grooves.
Affix the support arms by means of the
4 M6x16 screws and the SW4 allen
key to the desired height.
Remove 4 x M6x30 from the guide
column and connect base plate with
the 4 screws and the Torx 30.
Mounting of support arm
!Assemble or disassemble only
when column is in a lying position!
1 x
TORX 30
max. 15 Nm
4 x
1 x
.
A
Fasten fleece tape over the guide column.
889012120 0000 Page 19 of 27

M5x10
M6x12
adjust
fix
adjust
M5x10
M6x12
fix
Affix screen support
Screw together screen support and
place/hang on the arms.
Adjust screen supports with M5x10
and screw driver.
.
Tightly screw down M6x12 at the
supporting arms.
Attention: Optional mounting to ground plate
M6
4x
12x6,4
M6x25
4x
M6x25
12x6,4
M6
Mount base plate with 4 M6x25 screws
to the ground plate as shown in the
illustration.
2 x
2 x
4x
889012120 0000 Page 20 of 27

Connecting the control unit
889012120 0000 Page 21 of 27

889012120 0000 Page 22 of 27
E
AD CGFB
AJack for guide column ScreenMotion SME Basic 680 / 720 / 870
BJack without function
CJack for tabletop handset TMU 10
DJack for IR receiver SME
EJack for safety sensor
FJack for outlet (socket) with IEC connector
GJack for mains plug
Control unit SME
Handset TMU 10 (up/down)
IR Receiver SME
IR Remote control (up/down)
Switched mains socket (Country specific)
Mains connection cable
D
C
G
F

C: Connect the handset TMU 10.
D: Connect the IR receiver.
E: Connect the safety sensor.
F: Connect the TV set to the live outlet (socket).
There after plug the (conpling) connector into the
control unit (panel).
G: Connect the mains cable with the control unit first
and then with the socket.
Before the device is ready for operation the control unit needs to be
reset.
In order to reset the control unit, press and hold both arrow keys
“Up” and “Down”. The fitting moves into its home position at half
speed. Keep the keys pressed for another three seconds in this
position. After the time has expired release the keys and a
three-tone signal can be heard. Now the fitting automatically
moves up ca. 3-5 mm. The device is now ready to operate.
D C A G F
E
F3
Adjust send/receive channels
In order to operate two devices independently of each other,
they can be adjusted to function on 2 different send and receive
channels (A and B) (See fig. F2).
For the purpose of selecting send and receive channels (A and B)
there are two sliding switches located in the battery compartment
or the handset and at the front end of the IR receiver.
Please make sure that the sliding switch in the IR handset is in the
same position as the sliding switch at the IR receiver.
Select channel A for the first device. If you want to operate a
second device in the same room with the same remote set
the sliding switch on the second device at channel B.
i
First insert battery in the battery compartment of the infrared
remote control and press it down carefully on the contact side.
Be sure to insert the battery with the correct polarity (see fig. F3).
F2
A: Connect the column.
Now reset the control unit
Insert battery
889012120 0000 Page 23 of 27
F1
Connection assembly

708/748/898
680/720/870
Lifting limit
!
Up Down
Up
Down S
!
Up Down
Standard drive technology - please use
infrared remote control
Costomer-specific lifting limit
Override the upper lifting limit
Press and hold the “Up” key to extend the SME. In order to
retract the SME, press and hold the “Down” key. The fitting can
be moved from the bottom position (home position) to the
topmost lifting position. If the up or down movement of the
fitting is interrupted shortly and then continued in the same or
opposite direction the fitting pauses for a mandatory 2-3
seconds. This is the time required by the control unit to avoid
an accidental activation of the safety sensor.
If the remote control is out of order (battery dead, remote
control defective, remote control misplaced, etc.) the fitting can
be moved with the handset.
This function allows you to limit the height of the upward
movement of the fitting. The SME is pre-adjusted to reach the
maximum lifting position by the manufacturer. If you want the
fitting to stop at a position lower than the maximum lifting
position move it to the desired position by means of the arrow
keys “Up” and “Down”. Now press the key “S” three times
followed by pressing the “Up” key one time. This position is
now saved which the control unit will confirm with an acoustic
signal. The SME can now only be moved up to this position.
To override the upper lifting limit, move the SME up to the
position where it stops. Press the key “S” six times followed by
the “Up” key one time. The column moves now up to the
maximum lifting position at half speed as long as you keep the
“Up” key pressed.
As soon as the fitting reaches a position that is below the saved
lifting limit it is reactivated even if it was previously overridden.
To restore the factory setting or any other desired position
move the fitting to the maximum lifting position and save the
lifting limit anew. (See above)
889012120 0000 Page 24 of 27

889012120 0000 Page 25 of 27
(3)
Down
Up
Elevation protection sensor
2x 2x
Up Down
!
Auto- Memory- Function
This function allows an automatic movement from the top
and bottom position of your TV set. By pressing the arrow
keys “Down” and “Up” twice the bottom height and the
topmost adjusted lifting position can be reached.
The Auto Memory Function may only be used in
combination with an elevation protection sensor.
Device protection
= No operator
While the child-proof lock is activated each time a key is pressed it will produce an acoustic signal from
the control unit until the protection is deactivated.
!
“S” key
Automatic activation and deactivation of TV set
The outlet included in the set can be connected with the control unit and will then be automatically activated by it.
See page 23, illustration of control/ Jack “F”
Variant SME installed in furniture
The power supply is activated ca. 80 mm above the bottom position. If the ScreenMotion is moved to at least 80 mm below
the top position (maximum lifting position or lifting limit), the power supply remains activated. If the ScreenMotion is not
completely extended (e.g. only halfway), the control unit deactivates the power supply for safety reasons after one minute.
Thus heat accumulation and any damages to the device resulting from it are prevented.
Free-standing variant
The power supply is activated ca. 80 mm above the bottom position. If the fitting reaches a position below this point the
control unit interrupts the power supply.
Child-proof lock
Press and hold the "S" key (3) for 10 sec. to activate the child-proof lock. The control unit confirms this for you by producing
a two-tone sound. From now on the device will not accept any movement commands. To deactivate, press the "S" key (3)
again for 10 sec.
The controlunit confirms this for you by producing a one-tone sound.
While the child-proof lock is activated each time a key is pressed it will produce an acoustic signal from the control unit until
the protection is deactivated.

889012120 0000 Page 26 of 27
o Check if you can move the fitting up and down with the handset. If yes, are the sliding switches at
sender and receiver in the same position? (See page 23 for adjustment of send and receive channels.)
o Make sure that the IR receiver is not covered.
o Are the handset TMU 10 and the IR receiver connected with the correct jack? (See page 22.)
o Is the safety sensor plugged in? (If the scope of delivery does not include a safety sensor, this point is
irrelevant.)
o Is the power cord correctly plugged in at the control?
o Is the power cord correctly plugged in at the mains?
o Is the socket live and is it switched on?
o If the failure continues, please inform your service partner.
2. Control unit does not work, acoustic signal (beeping tone) can be heard
The control unit must be reset first. (See page 23 for how to reset the control unit)
If a reset is not successful, the following reasons can apply:
- The control unit is in it`s starting-up phase, e.g. fitting has been moved for more than two minutes. Fitting will pause for 18 min.
Try again after the pause.
- Check if the cild-proof lock is activated.
- Please check the plug connections.
- Should a power outage occur whille moving, the control unit must be reset anew (See page 23 for how to reset the control unit.)
If the control unit still does not work please inform your service partner.
Troubleshooting
1. Remote control does not work; General check
-Red LED on the infrared remote control does not light up while a key is pressed?
Check if battery has been inserted correctly, otherwise you may have to replace the battery!
If the LED does not light up after battery has been replaced, the remote control is defective.
Please call your service partner.
- The red LED on the infrared remote control lights up when key is pressed and the control unit
does not make a one-tone sound but there is no function?
Execute the following checks:
3. SME starts to move and immediately stops
Reset the control unit (See page 23 for how to reset the control unit.)
o The IR receiver may be covered.
o Check the IR receiver’s plug connection and all other plug connections if necessary.
o If the failure continues, please inform your service partner.
4. SME can only be moved with the handset, not with remote control
o Check if the channel settings of IR receiver and infrared remote control are in accordance.
(See page 23 for adjustment of send and receive channels.)
o Please check if the IR receiver is covered. If yes, remove cover.
o If the failure continues, please inform your service partner.

889012120 0000 Page 27 of 27
5. Return movement
The fitting stops and moves some mm in the opposite direction. This happens when the elevation protection is activated.
Possible reasons:
o Cable is too short
o Screen sways
o Object is in the way
• Function of safety sensor
The sensor is activated ca. one second after the start of any movement.
• After the safety sensor is activated a pause of ca. 5 sec. needs to be observed until the swaying of the
fitting stops.
6. Column remains in extended position
For maintenance reasons the column remains extended after 10000 lifts. Please call your service partner.
Subject to change without notice.
!
!
Kesseböhmer Ergonomietechnik GmbH
Siemensstrasse 6 · D-73235 Weilheim/Teck
Tel:+49(0)7023-108-0 · Fax:+49(0)7023-108-3200