SLP98UHV / Page 5
CONTROLS (CONTINUED)
Safety Controls - Flame sensor utilizes ame
rectication for safe and reliable operation.
Should ame fail to ignite, control will initiate 4 re-
attempts at ignition before locking out unit operation for
60 minutes.
Watchguard type circuit automatically resets ignition
controls after one hour of continuous thermostat demand
after unit lockout, eliminating nuisance calls for service.
Display LED - Seven segment LED displays alpha-
numeric information related to diagnostics as well
as system operation and status. Diagnostic codes
are held in non-volatile memory, immune from power
interruptions. Holds up to ten diagnostic codes in order
of occurrence for recall on demand. Port on blower door
allows for easy viewing.
DIP Switch Settings
(Note - DIP switches settings are not used with
icomfort™ thermostats)
Select Thermostat used - Single-Stage or Two-Stage.
Select Operation Mode - Two-Stage, Three-Stage or
Variable Capacity.
Two selectable second stage recognition times (7 and
12 minutes) are available on the control when the
furnace is used with a single-stage thermostat. When
used with a two-stage thermostat, furnace will only
initiate second stage operation with a second stage
thermostat demand.
Heating Speeds - A combination of DIP swtich settings
allow Normal, 7.5% increase, 15% increase, 7.5%
decrease or 15% decrease motor speed selection within
heating speed selected for ne tuning air volume. See
Blower Performance tables.
Cooling Speeds - A combination of DIP switch settings
allow Normal, 10% increase or 10% decrease motor
speed selection within cooling speed selected for ne
tuning air volume. See Blower Performance tables.
Blower Speed Ramping (Cooling Mode) - DIP switch
settings allow one of four blower speed proles during
cooling operation.
Prole A (factory setting) - Motor runs at 50% for 30
seconds, then at 82% for 7-1/2 minutes, then at 100%
(if needed) until demand is satised. Once demand is
met, motor runs at 50% for 30 seconds, then ramps
down to stop.
Prole B - Motor runs at 82% for 7-1/2 minutes and
then at 100% (if needed) until demand is satised. Once
demand is met,motor ramps down to stop.
Prole C - Motor runs at 100% until demand is
satised. Once demand is met, motor runs at 100% for
60 seconds, then ramps down to stop.
Prole D - Motor runs at 100% until demand is satised.
Once demand is met, motor ramps down to stop.
Dehumidication (Active or Humiditrol® Option) - A
jumper on the control control must be clipped to
enable active dehumidication and/or operation with
a Humiditrol® Whole-Home Dehumidication System.
A humidity controlling thermostat or device is also
required. During a call for cooling, air volume is
automatically reduced, forcing humidity removal by the
air conditioner or heat pump system. After the humidity
has reached the desired set-point the cooling air volume
returns to its designed rate. A dehumidication signal
from the thermostat reduces the cooling cfm to 70% of
the requested cooling cfm.
Dual-Fuel Operation - A jumper on the control must be
clipped to enable operation with a single or two-stage
heat pump. The indoor blower is started without delay
when a call for heat is received.
Two-Stage Compressor Operation - A jumper on the
control must be clipped to enable operation with a
two-stage compressor. The cooling blower speeds for
rst and second stage cooling will be dictated by the
applicable DIP switch settings.
Lennox System Operations Monitor Connection -
Monitors outdoor unit operation (communicating mode).
Blower On Time (Heating) - Blower on time is xed at
30 seconds, blower off time is adjustable from 60, 90,
120 and 180 seconds (factory setting - 90 seconds).
Blower Off Time (Cooling) - For air-conditioning
applications, blower on time is 2 seconds following
thermostat demand for cooling.
Blower off delay is 30 seconds at 50% of high cool cfm
(factory default).
Controls evaporator humidity by controlling blower and
compressor speed on two-stage outdoor units when
used with icomfort Wi-Fi™ or ComfortSense® 7000
thermostats.
Continuous Blower Speed - Adjustable continuous
blower speed is a percentage of the high cooling speed
selection. There are four selectable options (via DIP
switch settings) of 28%, 38% (default setting), 70% and
100%.
Accessory Terminals - Two accessory terminals
furnished for additional power supply requirements
for 120 volt (less than 1 amp) power humidiers and
powered air cleaners.
One 24 volt humidier output furnished for non-powered
humidiers.
Control is factory installed in the unit control box.
24 Volt Transformer
Furnished and factory installed in control box.
40VA transformer has circuit breaker wired in series.
Field Wiring Make-up Box
Furnished for line voltage wiring.
Factory installed internally on left side of furnace.
Box may be installed internally or externally on either
side of furnace.