7
2) 3-wire connection
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
1. Remove center terminal block screw.
2. Remove appliance groun wire (green) from
external groun connector screw. Connect
appliance groun wire an the neutral wire (white
or center wire) of power supply cor /cable un er
center, silver colore terminal block screw.
Tighten screw.
3. Connect the other wires to outer terminal block
screws. Tighten screws.
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
3) Optional 3-wire connection
1. Loosen or remove center terminal block screw.
2.
Connect neutral wire (white or center wire) of
power supply cor to the center, silver colore
terminal screw of the terminal block. Tighten screw.
1. External ground connector
2. Neutral grounding wire (green)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. 3/4 in. (1.9 cm) UL-listed strain relief
3. Connect the other wires to outer terminal block
screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of ryer
rear panel. Secure cover with hol - own screw.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of ryer
rear panel. Secure cover with hol - own screw.
6. Connect a separate copper groun wire from the
external groun connector screw to an a equate
groun .
1. External ground connector
2. Neutral grounding wire (green)
3. Neutral wire (white or center wire)
4.
Grounding path determined by a qualified electrician
1. 3-wire receptacle (NEMA type 10-30R)
2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. 3/4 in. (1.9 cm) UL approved strain relief
6. Ring terminals
7. Neutral (white or center wire)