July 2022 2/2 www.lifesafetypower.com
LSP PROWIRE | AMAG 8DR RACKMOUNT
System Specifications
Power Supplies FPO150 Power supply board, 4A/24V
B100 Secondard voltage module, 4A/12V class 2 power limited
Input 120/230VAC 50/60Hz | 83 Watts (0.69A)
Overload and short circuit protection
Over temperature protection
Polarized AC power supply disconnect
Battery Charging Independent built-in charger for sealed lead-acid or gel type batteries
Microprocessor dual rate charging of 12 or 24V battery sets
Automatic switchover to standby battery when AC fails
Zero voltage drop when switched over to battery backup
Supervision AC Fault (form "C" contacts)
System Fault (form "C" contacts)
System Fault conditions: Low or no battery | short to earth ground | power supply failure
Distribution Modules D8 8 auxiliary outputs, fused at 3A per output
F8 8 egress outputs, fused at 3A per output
Network Management NL2 Two port module. Monitors and reports power supply status. Tests and reports battery health status.
Enclosures RGA 2U rack mount (19.00"W x 3.50"H x 20.50"D) | Weight 24 lbs. | Z bracket wire management articulating arm
Wiring Suffix T8-A T= Tie Wrap 8= Door count A= M2150
T8-C T= Tie Wrap 8= Door count C= M4000
Regulatory Compliance UL / ULC UL294, ULC S319
CSA / FCC CSA C22.2 #107.1 | FCC Part 15, CSFM
System Examples
8DBC
A
M4000
C
LifeSafety Power
10027 S. 51st Street, Suite 102
Phoenix, AZ 85044 USA
PH 888-577-2898
info@lifesafetypower.com
P01-1024A07/22
LifeSafety Power warrants to the original purchaser only that all products will be free from defects in material or workmanship at time of shipment. This warranty is
non-transferable. Our obligation under this warranty is limited to repair or replacement, at the sole discretion of LifeSafety Power, of products that are defective in
material or workmanship at the time of shipment provided they were used within the specified ratings and installed in accordance with accepted engineering practices.
Products in the Unified Wired Systems Classification will be wired to the LifeSafety Power description of operation unless otherwise stated. At the time of installation it
is the obligation of the purchaser or final installer to verify that all wired terminations provide the desired operation. In no event shall LifeSafety Power be responsible for
any special, incidental or consequential damages even if LifeSafety Power has been advised of the possibility of such damages. Customer hereby agrees to indemnify
LifeSafety Power for and hold LifeSafety Power harmless from and against any and all loss, cost or expense (including reasonable attorneys’ fees) directly or indirectly
related to any claim with respect to Unified Wired™ systems classification products except to the extent any such claim shall result from the gross negligence or willful
misconduct of LifeSafety Power.